TFA 31.5010.02 CO2 Monitor Instruction Manual

June 9, 2024
TFA

31.5010.02 CO2 Monitor
Instruction ManualTFA 31.5010.02 CO2 Monitor

31.5010.02 CO2 Monitor

TFA 31.5010.02 CO2 Monitor - qr codeInstruction manuals Kat. Nr. 31.5010.02 www.tfa-dostmann.de/en/service/downloads /instruction-manuals
Thank you for choosing this instrument from TFA. Before you use this product

  • Please make sure you read the instruction manual carefully.
  • The operating instructions are enclosed with the device or can be downloaded at www.ffa-dostmann.de/en/service/downloads/instruction-manuals
  • This product should only be used as described within these instruc-tions.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual safe for future reference.

TFA 31.5010.02 CO2 Monitor - fig 1TFA 31.5010.02
CO2 Monitor - fig 2

Delivery contents

  • CO2 Monitor
  • USB-Type-C-1,5 m cable and power adaptor
  • Instruction manual

**Range of application and all the benefits of your new instrument at a

glance**

  • For monitoring the CO2 concentration in buildings, where people are present, eg: schools, offices, public facilities
  • High performance NDIR Dual Beam sensor
  • Large CO2 display with extended traffic light indication (green/yellow/ blue/red)
  • Display of indoor temperature (°C/°F) and humidity
  • Memory of the highest and lowest values of CO2, temperature and humi-dity
  • Alarm function for CO2 concentration
  • High contrast display with 4 brightness levels
  • Power connection via USB Type-C cable and power supply (included) or a suitable USB power source
  • Integrated rechargeable battery with 12 hours runtime

For your safety

  • This product is exclusively intended for the range of application described above. It should only be used as described within these instructions.

  • Unauthorized repairs, alterations or changes to the product are prohibited.
    Caution! Risk of electrocution!

  • Connect the device using the USB cable and the supplied power supply to a mains socket installed within your country’s electrical safety regulations and with a correct mains voltage (see nameplate) or connect the device via the USB cable to a suitable USB power source such as a computer, notebook.

  • The mains socket must be located near the equipment and it must be easily accessible.

  • Unplug the device immediately if any fault occurs.

  • The device and the power adapter must not come into contact with water or moisture. Only suitable for indoor use.

  • Do not use the device if the housing, the USB cable or the power adaptor are damaged.

  • Operate the device out of reach of persons (including children) who can-not fully appreciate the potential risks of handling electrical equipment

  • Connect the USB cable to the device and the power adaptor first and then plug the power adapter into the socket

  • Route the USB cable lead so that it does not come into contact with sharp-edged or hot objects.

Caution! Risk of injury!

  • Batteries containing lithium carry a risk of fire or explosion due to heat or mechanical damage!

  • Protect it from high temperatures. Do not throw into fire, short-circuit or take apart. If the device becomes hot while charging or the battery is no longer charged, this is a sign of a defect. Disconnect the device from the charging power source immediately.

  • The battery cannot and must not be replaced or removed by you. There is a risk of explosion if the battery is replaced incorrectly. If necessary, a qualified person can obtain instructions on how to dismantle the perma-nently installed battery from [email protected], should this be neces-sary for the purpose of repairing or recycling the product.
    Important information on product safety!

  • Do not expose the device to extreme temperatures, vibrations or shocks. Avoid direct sunshine.

  • The instrument is not unbreakable. In case of falling down parts can break.

Elements

A: LCD display (Fig. 1):
A 1: Battery symbol
A2:  CO2 alarm limit
A3: CO2 indication
A4: Display of minimum values
A5: CO2 value > 2000 ppm
A6: Extended traffic light indication
A7: Indoor temperature and humidity
A8: CO2 alarm symbol
A9: Display of maximum values
AIR COzNTROL UP — CO2 Monitor
B: Buttons (Fig. 1+2):
B 1: POWER/LIGHT sensor button
B 2: DOWN/CALIBRATE button
B 3: MEM button
B4: CO2 SET button
B 5: CO2 ALARM button
B 6: UP/button
B 7: RESET button
C: Housing (Fig. 3):
C 1: USB port

Getting started

Important note: When using the device for the first time, please make sure to connect the power supply uninterruptedly for 24 hours. The device will perform an automatic calibration within 24 hours.

  • Plug the supplied USB-C cable into the designated port on the device and connect the unit to the mains using the power adapter.
  • When using the mains adapter as a power supply, the integrated Li-Ion battery is charged. To fully charge, leave the device connected for approx-imately 4.5 hours.
  • If you operate the device without a power connection, the battery runtime is about 12 hours at highest brightness level. The battery symbol flashes when the battery needs to be charged (battery voltage below 3.3 V) and the device switches off after some time.

Operation

  • Press the POWER/LIGHT sensor button for 3 seconds to switch on the device.
  • The device will issue two beeps and all segments will be displayed briefly.
  • The display shows the current temperature and humidity.
  • The CO2 sensor goes into warm-up mode and starts a 150-second count-down. Afterwards the normal display appears. The device is ready for use.
  • Press the UPPC/button in normal mode to change between °C (Celsius) or °F (Fahrenheit) as temperature units.
  • Briefly press the POWER/LIGHT sensor button to adjust the brightness in 4 steps (high, medium, low, off).
  • Press the POWER/LIGHT sensor button for 3 seconds to deactivate the device

Traffic light display

The CO2 monitor shows the CO2 comfort level with an extended traffic light display:

CO2 value (ppm) Description
400-600 GOOD
601-1000 NORMAL
1001-1500 POOR
1501-2000 SERIOUS
2000 ⇑ SERIOUS +

 CO2 upper limit

  • Press briefly the CO2 SET button in normal mode. and 2000 ppm (default) or the last adjusted upper CO2 limit appear on the display. After 3 seconds, the device automatically returns to the normal mode.
  • Press and hold the CO2 SET button for 2 seconds to enter the setting mode. The value flashes.
  • Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper limit in steps of 1 Oppm, while the value flashes.
  • Press and hold the DOWN/CALIBRATE or UP/°C/°F
  • button in setting mode for fast mode.
  • Confirm the setting with the CO2 SET button.
  • The device will automatically quit the setting mode if no button is pressed for 20 seconds. The setting is saved.
  • Press the CO2 ALARM button in normal mode, to activate or deactivate the alarm function for the upper CO2 limit appears on the display when the alarm is activated.
  • If the measured CO2 value is above the upper limit setting, an alarm sounds and the CO2 alarm symbol flashes. Press any button to stop the alarm sound. The CO2 alarm symbol will continue flashing until the mea-sured CO2 value is below the set alarm limit

9. CO2, temperature and humidity maximum and minimum values

  • Press the MEM button in normal mode.
  • You can now read the highest measured values for CO2, temperature and humidity of the last 24 hours (display MAX).
  • Press the MEM button again.
  • The minimum values measured since the last 24 hours appear on the dis-play (display MIN.
  • Press the MEM button again to return to normal mode. The device will automatically quit the MAX/MIN mode if no button is pressed for 3 se-conds.
  • Press and hold the MEM button for 2 seconds during the highest or low-est values are displayed. The values will be deleted (display —-) and reset to the current state.

10. CO2 manual calibration function

  • For the whole calibration process, place the device outdoors. Choose a shady and dry place. Wait 15 minutes, the device must adapt to the envi-ronment
  • Use a pin to press the RESET button at the bottom. Wait until the normal display appears (see point 6. “Operation ).
  • Then press and hold the DOWN/CALIBRATE button for 2 seconds to enter the manual calibration mode. The CAL symbol flashes.
  • Wait approx. 20 minutes, until the normal display with a CO2 concentra-tion of 400 ppm (fresh air) appears. The calibration is completed and the device returns to normal state. Now you can use the device again as usual.
  • During the manual calibration operation, press the DOWN/CALIBRATE but-ton to exit the calibration mode.

Care and maintenance

  • Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
  • Turn off the device if you do not use it Press the POWER/LIGHT sensor button for 3 seconds.
  • Store the device in a dry place.

Troubleshooting

Problem Solution
No display on the device ➜ Press the POWER/LIGHT button for 3 seconds to

switch on the device
➜ Set the brightness with the POWER/LIGHT button
➜ Connect the device with USB cable and power adapter and charge the battery
➜ Check the connection
Incorrect indication Display Err| ➜ Use a pin to press the RESET button
Indication: LL / HH| ➜ Outside measuring range

If your device fails to work despite these measures, contact the retailer where you purchased the product.

Waste disposal

This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment.
Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.

Disposal of the electrical device
Caution! This device contains a built-in battery that cannot be removed without damaging the housing. Improper removal re- presents a safety risk. Hand in the device unopened at the collec- tion point; the device and battery will be disposed of properly.
This product is labelled in accordance with the EU Waste Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of this product in ordinary household waste. As a consumer, you are required to take end-of- life devices to a designated collection point for the disposal of electrical and electronic equipment, in order to ensure environmentally-compa- tible disposal. Observe the current regulations in place!

WARNING!
Batteries containing lithium can explode

  • Batteries and rechargeable batteries containing lithium (Li=lithium) pre-sent a high risk of fire and explosion due to heat or mechanical damage with potentially serious consequences for people and the environment. Pay particular attention to correct disposal.

 Specifications

Power supply| USB-Type-C-1.5 m cable with power supply (included)
Input: 100-240V AC 50/60Hz 0.5A max
Output: 5.0V DC 1.0A, 5.0W
Average active efficiency: ≥73.62%
No-load power consumption: ≤0.10 W
Built-in Li-Ion rechargeable battery
---|---
Capacity / Energy| 3.7V / 2000 mAh / 7.4Wh
Charging time| Approx. 4.5 hours
Battery runtime| Approx. 12 hours (at highest brightness level)
CO2
Measuring method
Measuring range
Resolution
Accuracy| Dual Beam Non-Dispersive-Infrared
Technology (NDIR)
400ppm – 5000ppm
1 ppm
± 50ppm ± 5%
Update interval| 4 seconds
Warm-up time| 150 seconds
Recommended operating temperature range CO2 sensor| +10…30°C
(Ideal conditions also for manual calibration)
Temperature
Measuring range
Resolution
Accuracy| 0 °C… +50°C (32°F…122°F)
0.1°C
±1 °C
Humidity
Measuring range
Resolution
Accuracy| 25…95%RH
1% RH
±5% RH
Housing dimension| 77 x 96 x 144 mm
Weight| 203 g (device only)

AIR CO2NTROL UP – CO2 Monitor
No part of this manual may be reproduced without written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice.
The latest technical data and information about this product can be found in our homepage by simply entering the product number in the search box www.ffa- dostmann.de E-Mail: info@tfa- dostmann.de TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany Commercial registration number Reg. Gericht Mannheim HRA 570186

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TFA User Manuals

Related Manuals