TFA 60.5018.01 Radio Projection Alarm Clock Instruction Manual

June 1, 2024
TFA

TFA 60.5018.01 Radio Projection Alarm Clock

TFA-60.5018.01-Radio-Projection-Alarm-Clock-PRODUCT

Radio-controlled projection alarm clock with indoor and outdoor temperature

Delivery contents

  • Radio-controlled projection alarm clock
  • Temperature transmitter (Cat. No. 30.3250.02)
  • Instruction manual
  • Power adaptor

Range of application and all the benefits of your new instrument at a glance

  • A digital projection of the radio-controlled time (DCF), indoor temperature outdoor temperature, or all 3 options alternately onto a wall or ceiling
  • Display of time and weekday written in full letters or abbreviated with the date
  • Outdoor temperature via a transmitter (max. 100 m) and indoor temperature
  • Highest precision radio-controlled clock
  • With time zone and manual setting option
  • Alarm with snooze function
  • Backlight with 4 brightness levels and adjustable dimming function
  • A projection with 2 brightness levels, can be rotated by 270°
  • Languages for weekdays and menu: German, English, Spanish, French

For your safety

  • This product is exclusively intended for the range of applications described above. It should only be used as described within these instructions.

Caution! Risk of electrocution!

  • Plug the device only into a mains socket installed within your country’s electrical safety regulations and with a correct mains voltage (see nameplate).
  • The main socket must be located near the equipment and it must be easily accessible.
  • Unplug the device immediately if any fault occurs.
  • The device and the power adapter must not come into contact with water or moisture. Suitable for indoor use only.
  • Do not use the device if the housing or the power adapter are damaged.
  • Operate the device out of reach of persons (including children) who cannot fully appreciate the potential risks of handling electrical equipment.
  • Only use the supplied power adapter.
  • Do not pull the plug out of the socket by its cable.
  • Route the main cable so it does not come into contact with sharp-edged or hot objects.

Radio-controlled projection alarm clock

WARNING! Risk of injury!

  • Keep the devices and the batteries out of reach of children.
  • Small parts can be swallowed by children (under three years old).
  • Batteries contain harmful acids and may be hazardous if swallowed. If a battery is swallowed, this can lead to serious internal burns and death within two hours. If you suspect a battery could have been swallowed or otherwise caught in the body, seek medical help immediately.
  • Batteries must not be thrown into a fire, short-circuited, taken apart, or recharged. Risk of explosion!
  • Low batteries should be changed as soon as possible to prevent damage caused by leaking. Make sure the polarities are correct. Never use a combination of old and new batteries together, nor batteries of different types. Remove the batteries if the device will not be used for an extended period of time. Avoid contact with skin, eyes, and mucous membranes when handling leaking batteries. In case of contact, immediately rinse the affected areas with water and consult a doctor.

CAUTION

  • Unauthorized repairs, alterations, or changes to the product are prohibited.
  • Do not expose the device to extreme temperatures, vibrations, or shocks.
  • Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
  • The transmitter is splashproof, but not watertight.

Elements

Projection alarm clock (base station/receiver)

LCD (Fig. 1)

TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-2

  • A1: Clock/alarm time
  • A2: DCF reception symbol
  • A3: Snooze symbol
  • A4: Alarm symbol
  • A5: Optional display
  • A6: Battery symbol transmitter
  • A7: Reception symbol transmitter
  • A8: Outdoor temperature
  • A9: Indoor temperature
  • A10: Battery symbol base station
  • A11: AUTO DIM symbol

Radio-controlled projection alarm clock

Projection (Fig. 1):

  • B1: Symbol outdoor temperature
  • B2: Alarm symbol (if the alarm is activated)
  • B3: Symbol indoor temperature
  • B4: Time/indoor temperature/outdoor temperature

Buttons (Fig. 2+3):TFA-60.5018.01-Radio-Projection-Alarm-Clock-
FIG-4 TFA-60.5018.01-Radio-Projection-Alarm-
Clock-FIG-5TFA-60.5018.01-Radio-Projection-
Alarm-Clock-FIG-6

Top:

  • C1: SNOOZE/LIGHT button
  • C2: Projection HIGH/LOW/OFF button

Front:

  • C3: ALARM button
  • C4: CALENDAR button

Back:

  • C5: – button
  • C6: SET button
  • C7: + button

D: Housing (Fig. 2)

  • D1: Battery compartment
  • D2: Power supply connection
  • D3: Projector arm
  • D4: ROTATE dial

Transmitter
E: Display (Fig. 4):

TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-7

  • E1: Channel 1,2,3
  • E2: Transmission signal
  • E3: Battery symbol for the transmitter
  • E4: Outdoor temperature

F: Housing (Fig. 4):

  • F1: Battery compartment
  • F2: Support for wall mounting or table standing
  • F3: Indentations for the holder for wall mounting

Radio-controlled projection alarm clock

G: Buttons in the battery compartment (Fig. 4):

  • G1: TX button
  • G2: 1 2 3 switch for channel selection

Getting started

Getting the transmitter started

  • Place the base station and the transmitter on a table at a distance of about 1.5 meters from each other. Avoid being close to possible sources of interference such as electronic devices and radio equipment.
  • Open the battery compartment of the transmitter and insert two new AA 1.5 V batteries, polarity as illustrated. All LCD segments will be displayed for a short moment.
  • The display shows the temperature. The switch is set to channel 1. Channel 2 + 3 are reserved for other models
  • Close the battery compartment.

Getting the projection alarm clock started

  • The projection alarm clock can be operated with 3 x 1,5 V AAA batteries (not included). The batteries maintain the clock operation in the event of a blackout or other power failure. In pure battery operation, the backlight is briefly activated with the SNOOZE/LIGHT button and the projection with the Projection HIGH/LOW/OFF button. For a permanent backlight and projection and to conserve battery power, use the supplied power adapter.
  • Fold out the projector arm. Insert the power adapter pin into the device jack and connect the plug to a wall socket.
  • The device is ready for use.
  • The device will alert you with a beep and all LCD segments will be displayed for a short moment.
  • Optional: Open the battery compartment and insert three new AAA 1.5 V batteries, polarity as illustrated. Close the battery compartment.

Reception of outdoor transmitter

  • The base station will scan the outdoor temperature. “- -,-” appears on the outdoor temperature display, and the reception symbol flashes.
  • If the reception is successful, the outdoor temperature and the reception symbol appear steadily on the base station display.
  • If the reception of outdoor temperature fails, check the batteries and try it again. If no reception is possible, “NO” appears after three minutes.
  • You can also start the transmitter search manually (e.g. if the transmitter signal is lost or if the batteries are changed). Press and hold the + button on the base station for two seconds. The reception symbol for the outdoor transmitter will be flashing.

Radio-controlled projection alarm clock

  • Press the TX button in the transmitter’s battery compartment. The transmission of the outdoor data takes place immediately and if the reception is successful, the outdoor temperature appears on the base station display.
  • If contact between the transmitter and receiver is lost at a later time after susuccessfuleception, “NO” appears after 30 minutes instead of the outdoor temperature. Reception is reactivated every hour.

Reception of the DCF frequency signal

  • After the reception of the outdoor values, the clock will now scan the DCF frequen-cy signal and the DCF symbol flashes on the display.
  • When the time code is successfully received after 3-10 minutes, the radio-con-trolled time and the DCF symbol will be shown steadily on the display. If the reception fails, scanning stops and will be repeated every 2 hours.
  • The DCF reception always takes place at 1:00, 2:00, and 3:00 in the morning. If the signal is not successfully received, further attempts will be taken at 4:00 and 5:00 p.m.
  • You can also activate the DCF reception manually. Press briefly the SET button in normal mode. The DCF reception symbol will be flashing.
  • Press the SET button again to stop the reception process. The DCF reception sym-bol disappears.
  •  There are 3 different reception symbols:
    • flashing symbol – reception is active
    • solid – reception is successful
    • no symbol – no DCF reception
  • If the clock cannot detect the DCF signal (e.g. due to interference, transmitting distance, etc.), the time can be set manually.
  • The clock will then work as a normal quartz clock (see: “Manual settings”).

Note on radio-controlled time

  • The time is transmitted from an atomic clock near Frankfurt am Main by a DCF-77 (77.5 kHz) frequency signal with a range of about 1,500 km. Your radio-controlled clock receives the signal, converts it, and always shows the exact time. The adjustment of Daylight Saving Time and Standard Time is also automatic.
  • Avoid being close to possible sources of interference that may affect radio reception (see “Location and mounting”).
  • During night-time, the atmospheric interference is usually less severe. A single daily reception is adequate to keep the accuracy deviation under 1 second.

Operation

Manual settings

  • Press and hold the + or – button in the setting mode for fast mode.
  • Press the SNOOZE/LIGHT button to quit the setting mode. The device will automatically quit the setting mode if no button is pressed for 10 seconds. The device will automatically use the settings you have made so far.

Manual setting of the clock and calendar

  • Press and hold the SET button for three seconds to enter the setting mode.
  • The language setting (default: DEUTSCH=German) flashes on the display.
  • Press the + or – button to select the language: GERMAN – DEUTSCH, ENGLISH, SPANISH – ESPANOL, or FRENCH – FRANCAIS, while the display flashes.
  • Confirm with the SET button and go to the next setting.
  • If you select ENGLISH, the display will now appear in English.
  • The sequence is shown as follows:
    • Button tone (default: BEEP OFF)
    • DCF reception (default: DCF ON)
    • Time zone -12/+12 (default: 00)
    • Hour, minutes
    • Year, month, date
    • Date format DATE/MONTH or MONTH/DATE (default DATE/MONTH)

Button tones

  • Press the + or – button to activate (BEEP ON) or deactivate (BEEP OFF) the button tone in setting mode.

DCF reception

  • By default, the DCF reception is activated (DCF ON), and after successful reception of the DCF signal no manual time setting is necessary.
  • Press the + or – button in setting mode if you want to deactivate the DCF reception (DCF OFF).
  • The DCF reception symbol disappears.
  • Once the DCF time reception is deactivated the clock must be manually set. No time zone will appear.
  • If the DCF reception is activated, the manually set time will be overwritten by the DCF time when the signal is received successfully.

Setting of the time zone

  • The time zone correction is needed for countries where the DCF signal can be received but the time zone is different from the DCF time (e.g. +1=one hour plus).
  • Press the + or – button to make the time zone correction (+12/-12).

Optional display

  • With the CALENDAR button, you can toggle the display in normal mode:
    • Weekday written in full letters
    • Weekday (3 digits) with date
    • Alarm time

Alarm clock function

Alarm time setting

  • Press and hold the ALARM button for three seconds to enter the setting mode. The alarm symbol and ALARM appear on the display.
  • The hour digits flash.
  • Press the + or – button to set the desired time.
  • Confirm the setting with the ALARM button.
  • Set the minutes in the same way.
  • Confirm the setting with the ALARM button.
  • The current time and the alarm symbol appear on the display.
  • The newly set alarm time appears in the optional display.
  • The alarm is activated.

Activate and deactivate the alarm

  • To deactivate and activate the alarm function, press the ALARM button in normal mode.
  • The last adjusted alarm time appears for 2 seconds on the display.
  • The alarm symbol and ALARM ON appear on the display if the alarm is activated.
  • ALARM OFF appears on the display, if the alarm is deactivated.
  • Wait some seconds until the display returns to normal mode to confirm the setting.
  • When the alarm is activated, the alarm starts to ring when the set alarm time is reached. The alarm symbol flashes.
  • If the alarm is not stopped manually, the ascending alarm tone automatically turns off after two minutes and it will be reactivated at the same set time on the following day.
  • When the alarm rings, press the SNOOZE/LIGHT button, and the snooze function is activated.
  • The alarm will be interrupted for 10 minutes. The snooze symbol flashes on the display.
  • Press any button (except SNOOZE/LIGHT) and the alarm will stop. GOOD DAY appears briefly on the display.
  • The alarm symbol remains on the display.

Projection and light

Note: Continuous illuminated backlight and projection only work when using the power adapter.

Projection

  • Press and hold the Projection HIGH/LOW/OFF button for three seconds to enter the setting mode.
  • The first option flashes on the display.
  • Use the + or – button to make the desired setting, while the display is flashing.
  • To confirm the setting, press the Projection HIGH/LOW/OFF button or wait some seconds until the display returns to normal mode.
  • The sequence is shown as follows:
    • TIME
    • IN TEMP indoor temperature
    • OUT TEMP outdoor temperature
    • TIME/TEMP time/indoor temperature/outdoor temperature alternating
  • Press the Projection HIGH/LOW/OFF button to adjust the projection brightness in 2 levels or to switch it off.
  • If the projection is switched on, the last selected display and the alarm symbol (if the alarm is activated) appear on the wall or ceiling.
  • Set the projection arm to the respective position.
  • With the ROTATE dial, you can rotate the image by 270°.
  • Battery operation: To temporarily activate the projection, press the Projection HIGH/LOW/OFF button.

Display backlight

  • Press the SNOOZE/LIGHT button to adjust the brightness in 4 levels (BACKLIGHT 1- 4) or to switch it off (OFF).
  • Wait some seconds until the display returns to normal mode to confirm the setting.
  • Battery operation: To temporarily activate the backlight, press the SNOOZE/LIGHT button.

Automatic dimming mode

  • If the auto-dim mode is activated, the weak backlight (level 1) turns on automatically for the set time. After that, the backlight goes to level 4.
  • Press and hold the SNOOZE/LIGHT button for 2 seconds. AUTO DIM appears on the display.
  • By default, the automatic dimming function is disabled. OFF flashes on the display.
  • To activate the function, press the + or – button (ON). The AUTO DIM symbol appears on the display.
  • Confirm with the SNOOZE/LIGHT button.
  • The start time flashes (START TIME 22:00 default). Press the + or – button to set the time (full hours).
  • Confirm with the SNOOZE/LIGHT button.
  • The end time flashes (STOP TIME 6:00 default). Press the + or – button to set the time (full hours).
  • Confirm the settings with the SNOOZE/LIGHT button. The display returns to normal mode and the AUTO DIM symbol remains.

Battery replacement

  • As soon as the battery symbol appears on the outdoor values display of the base station or the display of the outdoor transmitter, change the batteries of the outdoor transmitter.
  • Change the batteries of the base station, when the battery symbol appears on the indoor values display (optional).
  • Please note : When the batteries are changed, the contact between the outdoor transmitter and the base station must be restored – so always restart both devices or start a manual transmitter search (see “Reception of outdoor transmitter”).

Location and mounting

  • When placed outdoors, choose a shady and dry place for the transmitter. Direct sunlight may trigger incorrect measurement and continuous humidity damages the electronic components needlessly.
  • Place the projection alarm clock at your chosen location.
  • Avoid being close to possible sources of interference that may affect radio reception. It is recommended to keep a distance of at least 2 meters from possibly interfering sources (TV, computer, microwave, wireless phones, baby monitors) and large metal objects (e.g. refrigerator). Within solid walls, especially ones with metal parts, the transmission range can be reduced considerably. In extreme cases, please place the unit close to a window to improve reception.
  • Check whether the transmission from the transmitter to the base station is possible and whether the DCF radio clock signal can be received.
  • If necessary, choose another position for the outdoor transmitter and/or receiver.
  • To wall-mount the transmitter, screw the holder to the wall and click the outdoor transmitter into the holder.
  • Do not use the base station in the vicinity of radiators, other sources of heat, or in direct sunlight.

Troubleshooting

TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-8

If your device fails to work despite these measures, please contact the retailer where you purchased the product from for advice.

Waste disposal

This product and its packaging have been manufactured using high-grade materials and components that can be recycled and reused. This reduces waste and protects the environment. Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.

Disposal of the electrical device
Remove non-permanently installed batteries and rechargeable batteries from the device and dispose of them separately. This product is labeled by the EU Waste Electrical and Electronic Equipment Directive (WEEE). This product must not be disposed of in ordinary household waste. As a consumer, you are required to take end-of-life devices to a designated collection point for the disposal of electrical and electronic equipment, to ensure environmentally-compatible disposal. The return service is free of charge. Observe the current regulations in place!

Disposal of the batteries
Never dispose of empty batteries and rechargeable batteries with ordinary household waste. They contain pollutants that, if improperly disposed of, can harm the environment and human health. As a consumer, you are required by law to take them to your retail store or an appropriate collection site depending on national or local regulations to protect the environment. The return service is free of charge.  The symbols for the contained heavy metals are: Cd=cadmium, Hg=mercury, Pb=lead.

Specifications

TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-9 TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-10

No part of this manual may be reproduced without the written consent of TFA Dostmann. The technical data are correct at the time of going to print and may change without prior notice. The latest technical data and information about this product can be found on our homepage by simply entering the product number in the search box. EU Declaration of Conformity Hereby, TFA Dostmann declares that the radio equipment type 60.5018 complies with Directive 2014/53/EU. The full text of the EU Declaration of Conformity is available at the following internet address: www.tfa-dostmann.de/service/downloads/cewww .tfa-dostmann.de  E-Mail: info@tfa-dostmann.de TFA Dostmann GmbH & Co.KG, Zum Ottersberg 12, 97877 Wertheim, Germany Commercial registration number: Reg. Gericht Mannheim HRA 570186

www.tfa-dostmann.de/en/service/downloads/instruction-manuals

TFA-60.5018.01-Radio-Projection-Alarm-Clock-FIG-1

Instruction manual

Thank you for choosing this instrument from TFA.

Before you use this product

  • Please make sure you read the instruction manual carefully.
  • The operating instructions are enclosed with the device or can be downloaded at www.tfa-dostmann.de/en/service/downloads/instruction-manuals
  • This product should only be used as described within these instructions.
  • Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
  • Please take particular note of the safety advice!
  • Please keep this instruction manual safe for future reference.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TFA User Manuals

Related Manuals