TFA 31.5010.02 Dostmann CO2 Meter Instruction Manual
- June 4, 2024
- TFA
Table of Contents
TFA 31.5010.02 Dostmann CO2 Meter.
Thank you for choosing this instrument from TFA. Before you use this product
- Please make sure you read the instruction manual carefully.
- The operating instructions are enclosed with the device or can be downloaded at www.tfa-dostmann.de/en/service/downloads/instruction-manuals.
- This product should only be used as described within these instructions.
- Following and respecting the instructions in your manual will prevent damage to your instrument and loss of your statutory rights arising from defects due to incorrect use.
- Please take particular note of the safety advice!
- Please keep this instruction manual safe for future reference.
AIR CO2NTROL UP – CO2 Monitor
Delivery contents
- CO2 Monitor
- USB-Type-C-1,5 m cable and power adaptor
- Instruction manual
Range of application and all the benefits of your new instrument at a glance
- For monitoring the CO2 concentration in buildings, where people are present, eg: schools, offices, public facilities
- High-performance NDIR Dual Beam sensor
- Large CO2 display with extended traffic light indication (green/yellow/blue/red)
- Display of indoor temperature (°C/°F) and humidity
- The memory of the highest and lowest values of CO2, temperature and humidity
- Alarm function for CO2 concentration
- High contrast display with 4 brightness levels
- Power connection via USB Type-C cable and power supply (included) or a suitable USB power source
- Integrated rechargeable battery with 12 hours runtime
For your safety
- This product is exclusively intended for the range of applications described above. It should only be used as described within these instructions.
- Unauthorized repairs, alterations or changes to the product are prohibited.
Caution!
Risk of electrocution!
- Connect the device using the USB cable and the supplied power supply to a mains socket installed within your country’s electrical safety regulations and with a correct mains voltage (see nameplate) or connect the device via the USB cable to a suitable USB power source such as a computer, notebook.
- The mains socket must be located near the equipment and it must be easily accessible.
- Unplug the device immediately if any fault occurs.
- The device and the power adapter must not come into contact with water or moisture. Only suitable for indoor use.
- Do not use the device if the housing, the USB cable or the power adaptor are damaged.
- Operate the device out of reach of persons (including children) who can not fully appreciate the potential risks of handling electrical equipment.
- Connect the USB cable to the device and the power adaptor first and then plug the power adapter into the socket.
- Route the USB cable lead so that it does not come into contact with sharp-edged or hot objects.
Caution!
Risk of injury!
- Batteries containing lithium carry a risk of fire or explosion due to heat or mechanical damage!
- Protect it from high temperatures. Do not throw into fire, short-circuit or take apart. If the device becomes hot while charging or the battery is no longer charged, this is a sign of a defect. Disconnect the device from the charging power source immediately.
- The battery cannot and must not be replaced or removed by you. There is a risk of explosion if the battery is replaced incorrectly. If necessary, a qualified person can obtain instructions on how to dismantle the permanently installed battery from info@tfa-dostmann.de, should this be necessary for the purpose of repairing or recycling the product.
Important information on product safety!
- Do not expose the device to extreme temperatures, vibrations or shocks. Avoid direct sunshine.
- The instrument is not unbreakable. In case of falling down parts can break.
Elements
A: LCD display (Fig. 1):
- A 1: Battery symbol
- A 2: CO2 alarm limit
- A 3: CO2 indication
- A 4: Display of minimum values
- A 5: CO2 value > 2000 ppm
- A 6: Extended traffic light indication
- A 7: Indoor temperature and humidity
- A 8: CO2 alarm symbol
- A 9: Display of maximum values
AIR CO2NTROL UP – CO2 Monitor
B: Buttons (Fig. 1+2):
- B 1: POWER/LIGHT sensor button
- B 2: DOWN/CALIBRATE button
- B 3: MEM button
- B 4: CO2 SET button
- B 5: CO2 ALARM button
- B 6: UP/°C/°F button
- B 7: RESET button
- C: Housing (Fig. 3):
- C 1: USB port
Getting started
Important note:
When using the device for the first time, please make sure to connect the
power supply uninterruptedly for 24 hours. The device will perform an
automatic calibration within 24 hours.
- Plug the supplied USB-C cable into the designated port on the device and connect the unit to the mains using the power adapter.
- When using the mains adapter as a power supply, the integrated Li-Ion battery is charged. To fully charge, leave the device connected for approximately 4.5 hours.
- If you operate the device without a power connection, the battery runtime is about 12 hours at the highest brightness level. The battery symbol flashes when the battery needs to be charged (battery voltage below 3.3 V) and the device switches off after some time.
Operation
- Press the POWER/LIGHT sensor button for 3 seconds to switch on the device.
- The device will issue two beeps and all segments will be displayed briefly.
- The display shows the current temperature and humidity.
- The CO2 sensor goes into warm-up mode and starts a 150-second countdown. Afterward, the normal display appears. The device is ready for use.
- Press the UP/°C/°F button in normal mode to change between °C (Celsius) or °F (Fahrenheit) as temperature units.
- Briefly press the POWER/LIGHT sensor button to adjust the brightness in 4 steps (high, medium, low, off).
- Press the POWER/LIGHT sensor button for 3 seconds to deactivate the device.
Traffic light display
The CO2 monitor shows the CO2 comfort level with an extended traffic light display:
CO2 value (ppm) & Description
- 400-600 GOOD
- 601-1000 NORMAL
- 1001-1500 POOR
- 1501-2000 SERIOUS
- 2000 SERIOUS +
CO2 upper limit
- Press briefly the CO2 SET button in normal mode. and 2000 ppm (default) or the last adjusted upper CO2 limit appear on the display. After 3 seconds, the device automatically returns to normal mode.
- Press and hold the CO2 SET button for 2 seconds to enter the setting mode. The value flashes.
- Press the DOWN/CALIBRATE or UP/°C/°F button to set the desired upper limit in steps of 10ppm, while the value flashes.
- Press and hold the DOWN/CALIBRATE or UP/°C/°F button in the setting mode for fast mode.
- Confirm the setting with the CO2 SET button.
- The device will automatically quit the setting mode if no button is pressed for 20 seconds. The setting is saved
- Press the CO2 ALARM button in normal mode, to activate or deactivate the alarm function for the upper CO2 limit. appears on the display when the alarm is activated.
- If the measured CO2 value is above the upper limit setting, an alarm sounds, and the CO2 alarm symbol flashes. Press any button to stop the alarm sound. The CO2 alarm symbol will continue flashing until the measured CO2 value is below the set alarm limit.
CO2, temperature and humidity maximum and minimum values
- Press the MEM button in normal mode.
- You can now read the highest measured values for CO2, temperature and humidity of the last 24 hours (display MAX).
- Press the MEM button again.
- The minimum values measured since the last 24 hours appear on the display (display MIN.
- Press the MEM button again to return to normal mode. The device will automatically quit the MAX/MIN mode if no button is pressed for 3 se-conds.
- Press and hold the MEM button for 2 seconds during the highest or lowest values are displayed. The values will be deleted (display —-) and reset to the current state.
CO2 manual calibration function
- For the whole calibration process, place the device in an environment with a CO2 concentration of 400ppm (at an open window or outdoors). Wait a few minutes, then press and hold the DOWN/CALIBRATE button for 2 seconds to enter the manual calibration mode. The CAL symbol flashes. After 20 minutes the CAL symbol stops flashing, the calibration is com-pleted and the device returns to its normal state. Now you can use the device again as usual.
- During the manual calibration operation, press the DOWN/CALIBRATE but-ton to exit the calibration mode.
Care and maintenance
- Clean the device with a soft damp cloth. Do not use solvents or scouring agents.
- Turn off the device if you do not use it. Press the POWER/LIGHT sensor button for 3 seconds.
- Store the device in a dry place.
Troubleshooting
Problem & Solution
- No display on the device
- Press the POWER/LIGHT button for 3 seconds to switch on the device
- Set the brightness with the POWER/LIGHT button
- Connect the device with a USB cable and power adapter and charge the battery
- Check the connection
- Incorrect indication Display Err
- Use a pin to press the RESET button
- Indication: LL / HH
- Outside measuring range
If your device fails to work despite these measures, contact the retailer where you purchased the product.
Waste disposal
This product and its packaging have been manufactured using high-grade materials and components which can be recycled and reused. This reduces waste and protects the environment. Dispose of the packaging in an environmentally friendly manner using the collection systems that have been set up.
Disposal of the electrical device
Caution! This device contains a built-in battery that cannot be removed
without damaging the housing. Improper removal represents a safety risk. Hand
in the device unopened at the collection point; the device and battery will be
disposed of properly. This product is labeled in accordance with the EU Waste
Electrical and Electronic Equipment Directive (WEEE). Please do not dispose of
this product in ordinary household waste. As a consumer, you are required to
take end-of-life devices to a designated collection point for the disposal of
electrical and electronic equipment, in order to ensure environmentally-
compatible disposal. Observe the current regulations in place!
WARNING!
Batteries containing lithium can explode
- Batteries and rechargeable batteries containing lithium (Li=lithium) present a high risk of fire and explosion due to heat or mechanical damage with potentially serious consequences for people and the environment. Pay particular attention to correct disposal.
Specifications
- Power supply
- USB-Type-C-1.5 m cable with power supply (included)
- Input: 100-240V AC 50/60Hz 0.5A max Output: 5.0V DC 1.0A, 5.0W
- Average active efficiency: ≥73.62% No-load
- power consumption: ≤0.10 W Built-in Li-Ion rechargeable battery
- Capacity / Energy 3.7V / 2000 mAh / 7.4Wh
- Charging time Approx. 4.5 hours
- Battery runtime Approx. 12 hours (at highest brightness level)
- Measuring method Dual Beam Non-Dispersive-Infrared Technology (NDIR)
- Measuring range 400ppm – 5000ppm
- Resolution 400ppm – 5000ppm
- Resolution 1 ppm
- Accuracy ± 50ppm ± 5%
- Update interval 4 seconds
- Warm-up time 150 seconds
Temperature
- Measuring range 0 °C… +50°C (32°F…122°F)
- Resolution 0.1°C
- Accuracy ±1 °C
Humidity
- Measuring range 25…95%RH
- Resolution 1% RH
- Accuracy ±5% RH
- Housing dimension 77 x 96 x 144 mm
- Weight 203 g (device only)
No part of this manual may be reproduced without the written consent of TFA
Dostmann. The technical data are correct at the time of going to print and may
change without prior notice. The latest technical data and information about
this product can be found on our homepage by simply entering the product
number in the search box www.tfa-dostmann.de.