Xmart LSC-12 Landscape Series User Manual
- June 9, 2024
- xmart
Table of Contents
LSC-12
Landscape Series
USER MANUAL
TECHNICAL SPECIFICATIONS
Luminosity | 2000 |
---|
SOLAR PANEL
Type| Polycrystalline
Capacity| 18.5 W / 18V
Li-Ion BATTERY
Capacity| 14.8 Vdc / 115.4WH / 2.600 mAH
Charge & Discharge Temp.| Charge/0 to/a 45 °C Discharge/20 to/a 65 °C
Recharge Time| 9 H
ILLUMINATION
LED (OSRAM)| 48pcs
Light Color Temp.| 5700K to/a 6500K
Efficiency| 190 lm/W
OPERATION
Backup (Cloudy days)| Up to 7 nights
Operation Modes| Mode 1: 15% Until Dawn
Mode 2: 30%x5H + 15% Until Dawn
Mode 3: 35% Until Dawn
Mode Indication LED| Mode 1: Red
Mode 2: Green
Mode 3: Orange
Capacity Indication| Green: ³ 70%
Orange: 70% to/a 30%
Red: < 30%
IP Codes| IP65 / IK10
Directives| CE (IEC60598-1 / IEC60598-2-3 / EN55015 / EN61547)
Light Sensitivity| > 50 Lux: Off / Apagado
< 10 Lux: On / Encendido
Installation Height & Spacing| 4 to/a 6 m, 18 m
WARNING
- Keep the device away from fire and fire risk
- There are no replaceable parts inside the lamp. If disassembled warranty will be void.
- Do not remove battery for any other use. If backup time is too short, lamp’s battery needs to be recharged under bright sunlight
- Clean solar panel regularly for more efficient operation and longer backup (Suggestion: At least every 6 months)
- Long term storage might cause battery damage and leakage, Leakage might cause battery spontaneous combustion
- Operation temperature for this lamp must comply with Technical Specifications
Parts Identification
1. Solar Panel
2. LED Lamp
3. Assembling Bolt| 4. Switch
5. Indicator Light
6. Infrared Receiver
---|---
Special Features:
Polycrystalline Solar Panel
Li-ion Rechargeable Battery
Configurable Operation Modes
Equipped With Remote Control
Material: Aluminum alloy & PC
Installation Instructions
Fix the lamp to the pole with supplied screw
Solar Panel must be oriented toward sun and avoiding any shade for battery charging efficiency
Auto turn-off for charging during daytime Auto turn-on for lightning at night
IMPORTANT
- Use standard installation accessories
- If stored, charge the lamp every 3 months, to avoid battery damage
- If stored for more than 1 year without charging, make a charge & discharge process to assure battery is in good condition, otherwise it is not allowed to use.
Operation Instructions
Power On/Off: Press switch for 1.5 Sec, approx.
Mode Change: Press switch shortly to choose Mode 1, Mode 2, or Mode 3.
Available Modes:
Mode 1 (Red): 15% Untill dawn
Mode 2 (Green): 30% x 5Hrs + 15% Untill dawn
Mode 3 (Orange): 35% Untill dawn
Select Operation Mode according to your own requirements
Battery Power Indication:
Green:> 70%
Orange: Between 70% and 30%
Red: < 30%
Note: Indicator regularly shows Battery Capacity. When changing Operation
Mode it shows selected mode for 5 Sec, then it returns to show Battery
Capacity
T Button on Remote Control
Short press once for 100% bright for 1 hour
Short press twice (or more) for 100% bright for 2 hours
After selected time, lamp will go back to previous mode.
Dimensions
Packing Information
Model| Packing Type| Packed Units| Dimensions/Carton
(mm)| Carton Weight (Kg)
---|---|---|---|---
Net| Gros
LSC-12| Inner Box| 1| 560 x 210 x 560| 7.8| 8
Carton| 2| 580 x 440 x 580| 15.6| 16
Net and Gross weight information is for reference purposes only
LSC-12
www.xmart-ups.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>