Xmart HL-POLE-03 Solar Lamp User Manual
- June 9, 2024
- xmart
Table of Contents
Xmart HL-POLE-03 Solar Lamp
HL-POLE-03 – TECHNICAL SPECIFICATIONS / ESPECIFICACIONES TECNICAS
FEATURE
WARNING
- Keep the device away from fire and fire risk
- There are no replaceable parts inside the lamp. If disassembled warranty will be void.
- Do not remove battery for other use. If backup time is too short, lamp’s battery needs to be recharged under bright sunlight
- Clean solar panel regularly for more efficient operation and longer backup (Suggestion: At least every 6 months)
- Long term storage might cause battery damage and leakage, Leakage might cause battery spontaneous combustion
- Operation temperature for this lamp must comply with Technical Specifications
Parts Identification
- PIR
- Remote Control Receiver
- Indicator Light
- Lampshade
- Solar Panel
- Switch
Special Features
- Polycrystalline Solar Panel
- Li-ion Rechargeable Battery
- Configurable Operation Modes
- Material: Aluminum Alloy & PC
Installation Instructions
-
Use supplied screws to fix the lamp to the pole
-
Solar Panel must be oriented toward sun for battery charging efficiency
IMPORTANT
- Use standard installation accessories
- If stored, charge the lamp every 3 months, to avoid battery damage
- If stored for more than 1 year without charging, make a charge & discharge process to assure battery is in good condition, otherwise it is not allowed to use.
Operation Instructions
Power On/Off: Press switch for 1.5 Sec, approx.
Mode Change: Press switch shortly to choose Mode 1, Mode 2, or Mode 3.
Available Modes
- Mode 1 (Red): 120LMx5H + PIR 3000LM x 10s
- Mode 2 (Orange): 240lmx5H + PIR 3000LM x 10s
- Mode 3 (Green): 400LMx5H + 80LM/PIR 3000LM Until dawn
Select Operation Mode according to your own requirements
Battery Power Indication
- Green: > 80%
- Orange: Between 50% and 80%
- Red: < 50%
Note: Indicator LED regularly shows Battery Capacity. When changing Operation Mode it shows selected mode for 30 Sec, then it returns to show Battery Capacity
Remote Control
- ON/OFF: Turn lamp On and Off respectively
- M1 / M2 / M3: Operation Mode Setting
T: Timer
- Short press once for 100% bright for 10 min
- Short press twice (within 2 Sec) for 100% bright for 2 min.
- After selected time, lamp will go back to previous mode.
Cancel Timer: Long press T
Dimensions
Packing Information
References