Xmart 115Vac 1000VA Voltage Regulator User Manual

June 9, 2024
xmart

USER MANUAL – FUTURA-1000

VOLTAGE REGULATOR 1000VA
Models: 115Vac & 220Vac

Product Features

This unit is a state-of-the-art voltage regulator. Internal XMART voltage stabilizer is designed to protect all your electronic, electric, and computer equipment, suppressing all power failures from power main line. Among most common power failures to be suppressed: Transitory Overvoltage (Spikes), High- Voltage, Low-Voltage, and others. Power protection offered by FUTURA-1000 is designed to fulfil computer equipment, suchas : Monit or, Modem, Router , External Hard Discs Drives, etc. Your FUTURA-1000 can also protect your TV, Audio, and Video equipment, for as long as the regulator capacity is not exceeded. FUTURA-1000 main features are listed below:

  • Supplies clean and safe power. Suppresses transitory overvoltage (Spikes) of thousands of volts which might appear in your power line (L-N), caused by storms, and lightnings. Also stabilizes power line in case of high voltages, low voltages, or voltage fluctuations.
  • Doble protection against overloads and short-circuits, thanks to an Input Breaker which can be restarted in case of being tripped.
  • Offers 2 groups of power outlets with 4 power outlets each one. Group identified as “REGULATED+PROTECTED” includes voltage stabilization, as well as surge (spikes) suppression. Second group, identified as “PROTECTED ONLY”, offers surge suppression protection, without voltage regulation.
  • FUTURA-1000 includes 2 RJ11 connectors to protect telephone line for routers.
  • FUTURA-1000 includes a restart delay to avoid immediate power off and power on. During this restart delay, FUTURA-1000 checks main line stability before powering output power outlets. This delay can be configured to 2 Sec or 10 Sec, with a switch located on one side of the unit. Recommended delay for computer equipment is 10 Sec.
  • High Impact, Fire Retardant ABS plastic case. Includes an additive which extinguishes fire applied to case.

Product Description

  1. REGULATED+PROTECTED: 4 Power Outlets with Surge Suppression & Voltage Regulation
  2. PROTECTED ONLY: 4 Power Outlets with Surge Suppression, no Voltage Regulation
  3. Power Switch – Breaker (ON / OFF)
  4. AC Input Power Cord
  5. Green LED. Lights up when FUTURA-1000 is powered on
  6. Orange LED. Lights up when AC Input is either too high, or too low
  7. Time Delay Selection Switch (Up: 2 Sec, Down: 10 Sec)
  8. RJ11 Connectors (router) Surge protected.

Xmart 115Vac 1000VA Voltage Regulator - Fig 1

Installation

  1. Make sure the installation site for your FUTURQA-1000 complies with Tech Specs listed in this manual and that it is not close neither to heat source, nor to humidity. This regulator should nit be exposed to direct solar light.

  2. This unit can be installed, either on a horizontal surface or fixed to a wall, both horizontally, and vertically.
    Xmart 115Vac 1000VA Voltage Regulator - Fig 2

  3. Plug your FUTURA-1000 to a main line power outlet.

  4. Make sure, your equipment power switches are in OFF position.

  5. Plug equipment to be protected, to regulator’s power outlets. Either Regulated+Protected or Regulated Only, according to equipment priority.

  6. Push FUTURA-1000 Power Switch to turn on. At this moment Green LED should light up and the Protection Time starts counting. During this period, FUTURA-1000 makes sure the main line stays within voltage and frequency appropriate range. After 10 Seconds, if AC line is correct, power outlets are powered, as well as protected equipment.

  7. To protect your Router, connect telephone line to one of FUTURA-1000 RJ-11 connectors, and the other to the Router’s input port.

  8. Put your equipment power switches to ON position to start enjoying protected power supplied by your XMART FUTURA-1000.

Common Fault Check

  • If you detect any failure in your FUTURA-1000, contract your supplier or XMART Technical Service. This unit does not require any technical service, therefore, please do not open it. Otherwise, you might be exposed to dangerous voltages.
  • Is your FUTURA-1000 does not work, check the input breaker located in the power switch (rear panel of the unit). If it is tripped, push the button to restart it. Before restarting it, make sure the equipment connected to your FUTURA-1000 do not overload it. Breaker trips when detecting power consumption higher than FUTURA-1000 capacity.

Warranty: Terms and Conditions

XMART guarantees that all products are failure free in materials, manufacture, and design, by selling time. In case of any problem happens with this unit, the user must contact the supplier company that sold the unit, which will process the product revision for either reparation, or replacement (according to its own criteria) any unit considered to be defective. Check Warranty Terms and Conditions for your region in www.xmart-ups.com.

Technical Specifications

FUTURA-1000 1000
Capacity 1000VA Máx. Total
Surge Protected Outlets 1000VA / 1000W Total
Regulated Outlets 1000VA / 600W Total
Input
   Model 120V: Voltage (VAC) 115 Vac  //  (85 – 140 Vac)
   Model 220V: Voltage (VAC) 220 Vac  //  (180 – 280 Vac)
Frequency / Frecuencia (Hz) 50Hz/60 Hz
Output
   Model 120V: Voltage (115 +/- 10%)
   Model 220V: Voltage (220 +/-10%)
Power Outlets 8 x Nema 5-15R: (4 Regulated & Protected) + (4 Surge Protected)
Protections
Spikes / Sobre-tensiones Transitorias-Picos (AC LINES: L-N) Metal Oxide

Varistor (MOV):
   Model 120V:| Clamping : 455Vac // 48 Joules
   Model 220V:

  • Response Time / Respuesta < 1 nano-segundo| Clamping /: 300Vac // 140 Joules
    Overloads & Shortcircuits| Input Breaker
    Efficiency|
    100% load / A plena carga| 97%
    Indicators|
    LED| (ON / Encendido) & (Input OK / Entrada OK)
    Physical|
    Size| 18.0 x 9.5 x 11.9 cm
    Net Weight| 1,14
    Shipping| |
    ---|---|---
    Size  (cm)|       1 pallet (588 units per pallet)| 100 x 120 x 2150 cm
    Gross Weight (Kg.)|       1 pallet (588 units per pallet)| 960 Kg
    Operating Conditions|
    ---|---
    Temperature| 0-40°C
    Humidity| < 90% (no condensing)

Technical specifications can be modified to comply with special project requirements
Technical specifications may change without further notice

USA Headquarters:
Miami, FL33196
Florida, USA
xmartmiami@xmart-ups.com| EUROPEHeadquarters:
Sabadell, 08202
Barcelona, SPAIN
sales@xmart-ups.com| Latin America Headquarters:
Santiago de Chile, 8330669
Chile, CHILE
sales@xmart-ups.com
---|---|---

www.xmart-ups.com
VER. 2206.22-ENG

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>