inELS RFSG-1M Input Contact Converter

Characteristic

  • This wireless contact converter is especially appropriate for wireless transmission of information on switching HDO.
  • Thanks to the network supply, it can also be used for partial transmission of information for control of an appliance or device.
  • One-module design of the unit with mounting into switchboard.
  • After leading in power /disconnecting the supply to the “S” terminals, the switch on/off command is transmitted and then this command is being periodically transmitted in an interval of 2 min.
  • The button TEST on the controller is used to assign to a switching unit.
  • Option of setting light scenes, where with a single press, you can control multiple units of iNELS RF Control.
  • The package includes an internal antenna AN-I, in case of locating the converter in a metal switchboard, you can use the external antenna AN-E for better signal reception.
  • Range up to 160 m (in open space), if the signal is insufficient between the controller and unit, use the signal repeater RFRP-20.
  • Communication frequency with bidirectional protocol iNELS RF Control.

Compatibility
The RFSG-1M converter is compatible with all iNELS RF Control switching components.

Radio frequency signal penetration through various construction materials inELS-RFSG-1M-Input-Contact-Converter-FIG-1

80 – 95 % 80 – 90 % 60 – 90 % 20- 60 % 0 – 10 %
wooden structures with plaster boards common glass brick walls reinforced
concrete metal partitions

Indication, manual control

inELS-RFSG-1M-Input-Contact-Converter-FIG-2

Assembly

  • mounting into switchboard
  • Connection

inELS-RFSG-1M-Input-Contact-Converter-FIG-3

Programming

  1. Press of programming button on ac-tuator (e.g. RFSAI-61B-SL) for 1 second will activate actuator into program-ming mode. LED is fl ashing in 1s in-terval.
  2. Press and hold the TEST button on RF-SG-1M for more than 4s to automati-cally assign the RFSG-1M transmitter to the actuator.
  3. Press of programming button on actuator RFSAI-61B-SL shorter then 1 second will fi nish programming mode, LED switches off .

Indicators, settings

After connecting the power supply, the red LED lights up continuously for 3 seconds and then the selected controller function is indicated by fl ashing LED for 5 seconds.

  • double fl ash – standard RFIO2 operating mode
  • rapid fl ashing – mode of compatibility with older actuators
    If you do not want to change the function of the controller, you must not press the TEST button during this time.

To switch between RFIO2 mode and compatibility mode:
If you need to change the operating mode of the controller, after connecting the power supply, when the LED is lit continuously, press the TEST button and hold until the LED starts to signal the changed mode (double fl ash or rapid fl ash). Then the button must be released. The selected function mode is stored in memory and after connecting the power supply, the controller continues to operate in the same mode.

Technical parameters

Supply voltage:

Apparent input:
Dissipated power:
Supply voltage tolerance:
Power supply indication:
Input
Control voltage:
Control input power:
Control terminals:
The length of control impulse:
Transmission indication / function:
Transmitter frequency:
Signal transmission method:
Range in free space:
Minimum control distance:
Output for RF antenna:
Other data
Operating temperature:
Operating position:
Mounting:
Protection:
Overvoltage category:
Contamination degree:
Connecting conductor cross-

section (mm2):

Dimensions:
Weight:
Related standards:

Max Tightening Torque for antenna connector is 0.56 Nm.

Attention:
When you instal iNELS RF Control system, you have to keep minimal distance 1 cm between each units. Between the individual commands must be an interval of at least 1s.

Warning: Instruction manual is designated for mounting and also for user of the device. It is always a part of its packing. Installation and connection can be carried out only by a person with adequate professional qualifi cation upon understanding this instruction manual and functions of the device, and while observing all valid regulations. Troublefree function of the device also depends on transportation, storing and handling. In case you notice any sign of damage, deformation, malfunction or missing part, do not install this device and return it to its seller. It is necessary to treat this product and its parts as electronic waste after its lifetime is terminated. Before starting installation, make sure that all wires, connected parts or terminals are de-energized. While mounting and servicing observe safety regulations, norms, directives and professional, and export regulations for working with electrical devices. Do not touch parts of the device that are energized – life threat. Due to transmissivity of RF signal, observe correct location of RF components in a building where the installation is taking place. RF Control is designated only for mounting in interiors. Devices are not designated for installation into exteriors and humid spaces. The must not be installed into metal switchboards and into plastic switchboards with metal door – transmissivity of RF signal is then impossible. RF Control is not recommended for pulleys etc. – radiofrequency signal can be shielded by an obstruction, interfered, battery of the transceiver can get fl at etc. and thus disable remote control.

ELKO EP declares that the RFSG type of equipment complies with Directives 2014/53/EU, 2011/65/EU, 2015/863/EU and 2014/35/
EU. The full EU Declaration of Conformity is at: https://www.elkoep.com /wireless-contact-converter-230v—rfsg-1m

ELKO EP, s.r.o.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals