SAFETY REQUIREMENTS
This unit is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities, or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
unit by a person responsible for their safety. Children should be supervised
to ensure that they do not play with the unit.
This appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities or lack of experience
and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved.
Cleaning and user maintenance shall not be made by children without
supervision. Children shall not play with the appliance.
Precautions must be taken to avoid the back-flow of gases into the room from
the open flue of gas or other fuel-burning appliances.
Do not attach the product to the support using glue or adhesives. Use only the
fastening method specified in the «User’s manual».
All user’s manual requirements as well as the provisions of all the applicable
local and national construction, electrical, and technical norms and standards
must be observed when installing and operating the unit.
Disconnect the fan from power supply prior to any connection, servicing and
repair operations. Check the unit for any visible damages of the impeller and
the casing before starting installation. The casing internals must be free of
any foreign objects which can damage the impeller blades.
While mounting the unit, avoid compression of the casing! Deformation of the
casing may result in the motor jam and excessive noise. Misuse of the unit and
any unauthorized modifications are not allowed.
Do not expose the unit to adverse atmospheric agents (rain, sun, etc.).
Transported air must not contain any dust or other solid impurities, sticky
substances, or fibrous materials.
Do not use the unit in a hazardous or explosive environment containing
spirits, gasoline, insecticides, etc.
Do not close or block the intake or extract vents in order to ensure the
efficient air flow.
Do not sit on the unit and do not put objects on it.
The information in this user’s manual was correct at the time of the
document’s preparation.
The Company reserves the right to modify the technical characteristics,
design, or configuration of its products at any time in order to incorporate
the latest technological developments.
| THE PRODUCT MUST BE DISPOSED SEPARATELY AT THE END OF ITS SERVICE LIFE.
DO NOT DISPOSE THE UNIT AS UNSORTED DOMESTIC WASTE.
---|---
PURPOSE
The ventilator is designed to ensure continuous mechanical air exchange in flats, cottages, hotels, cafés and other domestic and public premises. Designed for in-wall installation. In sunny weather, the ventilator provides ventilation due to the built-in fan, which is powered by a solar battery. In cloudy weather and at night, natural ventilation is created due to the difference in pressure in the room and outside.
DELIVERY SET
Name | Name Number |
---|---|
Internal grille with a built-in fan | 1 pc. |
Outer ventilation hood with a built-in solar battery | 1 pc. |
Telescopic air duct | 1 pc. |
Screws with dowels | 8 pcs |
User’s manual | 1 pc. |
Packing box | 1 pc. |
TECHNICAL DATA
Voltage [V]| Current [A]| Impeller RPM [min-¹]| Air flow
[m³/h]
---|---|---|---
9| 0.064| 1390| 13
12| 0.073| 1754| 15
15| 0.083| 2140| 17
18| 0.092| 2490| 20
The dimensions of the ventilator are shown below.
DESIGN AND OPERATING PRINCIPLE
The ventilator consists of an internal grille, telescopic air duct, and
external grille. The internal grille is made of high quality ABS plastic and
is equipped with a dust filter (G3 class). The built-in regulator allows you
to change the supply air volume or completely close the ventilation duct. The
fan is installed on the flange of the grille. The length of the telescopic PVC
air duct is adjustable.
The outer grille is made of high-quality UV-resistant ASA plastic. The solar
panel is attached to the surface of the hood to power the motor.
The solar battery provides autonomous power for the fan motor. The fan creates
a more intense air exchange than with conventional passive ventilation.
The electrical parameters of the battery vary according to the intensity of
the solar flux.
In the dark, the ventilator functions as a passive ventilation element.
MOUNTING AND SET-UP
| READ THE USER’S MANUAL BEFORE INSTALLING THE UNIT. BEFORE INSTALLING
ADDITIONAL EXTERNAL DEVICES, READ THE RELEVANT USER MANUALS.
---|---
| DO NOT BLOCK THE AIR DUCT OF THE INSTALLED VENTILATOR WITH DUST
ACCUMULATING MATERIALS, SUCH AS CURTAINS, CLOTH SHUTTERS, ETC.
AS IT PREVENTS AIR CIRCULATION IN THE ROOM.
---|---
To install an external ventilation hood or grille, it is necessary to have access to the external surface of the wall at the place of installation.
-
Prepare a round core hole in the outer wall.
The diameter of the hole depends on the specific model of the ventilator and is indicated in the table of overall dimensions in the «Technical data» section.
-
Install the telescopic air duct in the hole in such a way that its sections coincide with the outer and inner surface of the wall. For ease of installation, use mounting wedges. Install the air duct with the minimum slope of 3 mm downwards from the outer wall side.
-
Install the outdoor grille, connecting the power from the solar battery to the fan.
-
Install the internal grille.
-
Adjust the airflow regulator.
-
Assemble the internal grille.
| ALL THE COMPONENTS OF THE UNIT ARE ITS INTEGRAL PARTS. MAINTAINING THE
FACTORY CONFIGURATION AND FORM FACTOR IS ABSOLUTELY ESSENTIAL FOR THE PROPER
AND CONSISTENT FUNCTIONING OF THE UNIT ANY UNAUTHORISED ALTERATIONS TO THE
UNIT FORM FACTOR OR FAILURE TO ADHERE TO THE ELECTRICAL CONNECTIONS DIAGRAM
SHALL RELIEVE THE MANUFACTURER FROM LIABILITY FOR ANY RESULTING MALFUNCTIONS
AND VOID THE UNIT WARRANTY.
---|---
TECHNICAL MAINTENANCE
The technical maintenance includes periodic cleaning of the grille and solar battery surfaces from accumulated dust and dirt, as well as washing the built- in filter as it becomes dirty, but at least once every 6 months. To clean the unit, wipe its surfaces with a cloth or a brush wetted in a mild soap solution, then wipe the surfaces dry. Avoid penetration of water inside the electric motor and other electric parts.
TROUBLESHOOTING
POSSIBLE REASONS AND TROUBLESHOOTING
Problem | Possible reasons | Troubleshooting |
---|---|---|
When switching on the ventilator, the fan does not start. | No power supply. |
Make sure the power supply line is connected correctly, otherwise troubleshoot
a connection error.
The motor is jammed, the impeller blades are soiled.| Turn the ventilator off.
Troubleshoot the motor jam and impeller clogging. Clean the blades. Turn the
ventilator on.
Low air flow.| The filter or the fan is clogged.| Clean or replace the filter,
clean the fan.
The solar battery is dirty.| Clean the solar battery.
Noise, vibration| The impeller is clogged.| Clean the impeller.
Loose screw connection of the unit casing or the outer ventilation hood.|
Tighten the screws of the ventilator or the outer ventilation hood.
STORAGE AND TRANSPORTATION REGULATIONS
- Store the unit in the manufacturer’s original packaging box in a dry closed ventilated premise with temperature range from +5 °C to + 40 °C and relative humidity up to 70 %.
- Storage environment must not contain aggressive vapors and chemical mixtures provoking corrosion, insulation, and sealing deformation.
- Use suitable hoist machinery for handling and storage operations to prevent possible damage to the unit.
- Follow the handling requirements applicable for the particular type of cargo.
- The unit can be carried in the original packaging by any mode of transport provided proper protection against precipitation and mechanical damage. The unit must be transported only in the working position.
- Avoid sharp blows, scratches, or rough handling during loading and unloading.
- Prior to the initial power-up after transportation at low temperatures, allow the unit to warm up at operating temperature for at least 3-4 hours
MANUFACTURER’S WARRANTY
The product is in compliance with EU norms and standards on low voltage
guidelines and electromagnetic compatibility. We hereby declare that the
product complies with the provisions of Electromagnetic Compatibility (EMC)
Directive 2014/30/EU of the European Parliament and of the Council, Low
Voltage Directive (LVD) 2014/35/EU of the European Parliament and of the
Council and CE-marking Council Directive 93/68/EEC. This certificate is issued
following test carried out on samples of the product referred to above.
The manufacturer hereby warrants normal operation of the unit for 24 months
after the retail sale date provided the user’s observance of the
transportation, storage, installation, and operation regulations. Should any
malfunctions occur in the course of the unit operation through the
Manufacturer’s fault during the guaranteed period of operation, the user is
entitled to get all the faults eliminated by the manufacturer by means of
warranty repair at the factory free of charge. The warranty repair includes
work specific to elimination of faults in the unit operation to ensure its
intended use by the user within the guaranteed period of operation. The faults
are eliminated by means of replacement or repair of the unit components or a
specific part of such unit component.
The warranty repair does not include
- routine technical maintenance
- unit installation/dismantling
- unit setup
To benefit from warranty repair, the user must provide the unit, the user’s manual with the purchase date stamp, and the payment paperwork certifying the purchase. The unit model must comply with the one stated in the user’s manual. Contact the Seller for warranty service.
The manufacturer’s warranty does not apply to the following cases
- User’s failure to submit the unit with the entire delivery package as stated in the user’s manual including submission with missing component parts previously dismounted by the user.
- Mismatch of the unit model and the brand name with the information stated on the unit packaging and in the user’s manual.
- User’s failure to ensure timely technical maintenance of the unit.
- External damage to the unit casing (excluding external modifications as required for installation) and internal components caused by the user.
- Redesign or engineering changes to the unit.
- Replacement and use of any assemblies, parts and components not approved by the manufacturer.
- Unit misuse.
- Violation of the unit installation regulations by the user.
- Violation of the unit control regulations by the user.
- Unit connection to power mains with a voltage different from the one stated in the user’s manual.
- Unit breakdown due to voltage surges in power mains.
- Discretionary repair of the unit by the user.
- Unit repair by any persons without the manufacturer’s authorization.
- Expiration of the unit warranty period.
- Violation of the unit transportation regulations by the user.
- Violation of the unit storage regulations by the user.
- Wrongful actions against the unit committed by third parties.
- Unit breakdown due to circumstances of insuperable force (fire, flood, earthquake, war, hostilities of any kind, blockades).
- Missing seals if provided by the user’s manual.
- Failure to submit the user’s manual with the unit purchase date stamp.
- Missing payment paperwork certifying the unit purchase.
| FOLLOWING THE REGULATIONS STIPULATED HEREIN WILL ENS
---|---
| USER’S WARRANTY CLAIMS SHALL BE SUBJECT TO REVIEW ONLY UPON
PRESENTATION OF THE UNIT, THE PAYMENT DOCUMENT AND THE USER’S MANUAL WITH
THE PURCHASE DATE STAMP.
---|---
COSTOMER SUPPORT
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>