TESY 10047, 12047, 15047 Electric Water Heater Instruction Manual
- June 9, 2024
- TESY
Table of Contents
- IMPORTANT RULES
- TECHNICAL PARAMETERS
- DESCRIPTION AND PRINCIPLE OF WORK
- MOUNTING AND SWITCHING ON
- RUST PROTECTION MAGNESIUM ANODE
- OPERATION
- MODELS EQUIPPED WITH A HEAT EXCHANGER (SERPENTINE TUBE) – FIG.1C, FIG.1D,
- PERIODIC MAINTENANCE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ELECTRIC WATER HEATER
Instructions for use and maintenance
Instruction Manual
IMPORTANT RULES
- This technical description and instructions manual was prepared in order to acquaint you with the product and the conditions of proper installation and use. These instructions were also intended for use by qualified technicians, who shall perform the initial installation, or disassembly and repairs in the event of a breakdown.
- Following the current instructions will primarily be of interest to the consumer, but along with this, it is also one of the warranty conditions, pointed out in the warranty card, so that the consumer can benefit from the free warranty services. The producer is not responsible for damages in the appliance that have appeared as a result of operation and/or installation not corresponding to the instructions here.
- The electric water heater complies with the requirements of EN 60335-1, EN 60335-2-21.
- This appliance can be used by children aged from 3 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Children aged from 3 to 8 years are only allowed to operate the tap connected to the water heater.
- Cleaning and user maintenance shall not be made by children without supervision.
Attention! Improper installation and connection of the appliance may make
it hazardous for the health and life of consumers. It may cause grievous and
permanent consequences, including but not limited to physical injuries and/or
death. Improper installation and connection of the appliance may also lead to
damage to the consumers’ property /damage and/ or destruction/, or to that of
third persons, as a result of, but not limited to flooding, explosion and/or
fire.
Installation, connection to the main water and power supply, and putting into
operation must be carried out by certified electricians and technical
personnel certified in installation of this category of appliances, who have
obtained their license in the state where the installation and commissioning
of the appliance are carried out, and in compliance with its local
legislation.
All alterations and modifications to the water heater’s construction and
electrical circuitry are forbidden. If such alterations or modifications are
established during inspection, the appliance’s warranty shall be null and
void. Alterations and modifications shall mean each instances of removal of
elements incorporated by the manufacturer, building in of additional
components into the water heater, replacement of elements by similar elements
unapproved by the manufacturer.
Mounting
The water heater must only be mounted in premises with normal fire resistance.
- In the event the device is mounted in a bathroom, the selected location must exclude the possibility of water spray contact from the showerhead or portable showerhead attachment.
- The water heater is designed to operate only in closed and heated premises where the temperature is not lower than 4°C and it is not designed to operate in a continuous protracted regime.
- The appliance is affixed to a wall via the mounting brackets attached to the unit’s body (if the brackets are not attached to the unit’s body, they must be affixed in place via the provided bolts).
Water heater connection
-
The appliance is intended to supply hot water to household sites equipped with a piping system working at pressure below 6 bar (0,6 Mpa).
-
The safety return-valve must be mounted on the cold water supply pipe, in observance of the direction arrow stamped on its body, indicating the incoming water’s direction. Additional stopcocks must not be mounted between the safety return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it must be bought additionally. For mechanisms operating in accordance with EN 1487 the announced operational pressure must be no more than 0.7 MPa. For other protection valves, the pressure at which they are calibrated must be 0.1 MPa lower than the one marked on the appliance’s sign. In these cases the safety valve which the appliance is supplied with should not be used. -
The safety valve and the pipe between the valve and the water heater must be protected from freezing. During hose draining – its free end must be always open to the atmosphere (not to be immersed). Make sure that the hose is also protected from freezing.
-
In order to secure the water heater’s safe operation, the safety return-valve must undergo regular cleaning and inspections for normal functioning /the valve must not be obstructed/, and for the regions with highly calcareous water it must be cleaned from the accumulated lime scale. This service is not provided under warranty maintenance.
-
In order to prevent injury to user and third persons in the event of faults in the system for providing hot water, the appliance must be mounted in premises outfitted with floor hydro insulation and plumbing drainage. Don’t place objects, which are not waterproof under the appliance under any circumstances. In the event of mounting the appliance in premises not outfitted with floor hydro insulation, a protective tub with a plumbing drainage must be placed under the appliance.
-
During operation – regime of heating the water – water drops through the drainage opening of the protection valve are usual. The protection valve should be left open to the atmosphere. Measures should be taken to lead and collect the leakages in order to prevent damages.
-
If the probability exists for the premise’s temperature to fall below 0°С, the water heater must be drained.
In the event you must empty the water heater, first you must cut off its power supply. The inflow of water from the water mains must first be terminated and the hot water tap of the mixing-faucet must be opened. The water tap 7 (fig 4) must be opened to drain the water from water tank. If there is no such tap build in the pipe line, than the water can be drain directly from inlet pipe of water tank after when you disconnect it from water main. -
These instructions shall also apply to water heaters equipped with a heat exchanger – Section VII. These are appliances with inbuilt heat exchanger and are intended to be connected to the heating system with maximum temperature of the heat carrier of 80°C.
Connection to the electrical network
-
Do not switch on the water heater unless you established it was filled with water..
-
Upon connecting the water heater to the electric mains care must be taken to connect the safety lead.
-
Models without power cord, the circuit has to be supplied with a safety fuse (16A) and with inbuilt device to ensure disconnection of all pole pieces in the conditions of over-voltage from category III.
-
If the power supply cord (of models that have one) is damaged, it must be replaced by a service representative or a person with similar qualification, to avoid any risk.
-
For water heaters intended for horizontal mounting the power supply conductor insulation from fixed wiring must be protected from direct contact with
the flange (in zone under the plastic panel). For example, insulating sleeving having temperature rating higher than 90 °C can be used. -
During the heating the appliance could produce a hissing noise (the boiling water). This is common and does not indicate any damage. The noise gets higher with the time and the reason for this is the accumulation of limestone. To remove the noise the appliance must be cleaned from limestone. This type of cleaning is not covered by the warranty.
Dear Clients,
The TESY team would like to congratulate you on your new purchase. We hope
that your new appliance shall bring more comfort to your home.
TECHNICAL PARAMETERS
-
Nominal volume V, liters – see the appliance’s rating plate
-
Nominal voltage – see the appliance’s rating plate
-
Nominal power consumption – see the appliance’s rating plate
-
Nominal pressure – see the appliance’s rating plate
This is not the water mains pressure. This is the pressure that is announced for the appliance and refers to the requirements of the safety standards. -
Water heater type – closed type accumulating water heater, with thermalinsulation
For models without heat exchanger (coil) -
Daily energy consumption – see Annex I
-
Rated load profile – see Annex I
-
Quantity of mixed water at 40°C V40 litres – see Annex I
-
Maximum temperature of the thermostat – see Annex I
-
Default temperature settings – see Annex I
-
Energy efficiency during water heating – see Annex I
For models with heat exchanger (coil) -
Storage volume in litres – see Annex II
-
Standing loss – see Annex II
DESCRIPTION AND PRINCIPLE OF WORK
The appliance is designed to operate in regions where the water hardness is
not more than 10°dH. In case that it is installed in a region where the water
is harder it is possible that limestone precipitation accumulate very fast.
This can cause a specific noise during heating, as well as fast damaging of
the electrical part. For regions with harder water yearly cleaning of the
limestone precipitation in the appliance is recommended, as well as usage of
not more than 2 kW of heating power.
The appliance consists of a body, flange at the bottom side /for water heaters
intended for vertical mounting/ or at the sides /for water heaters intended
for horizontal mounting/, protective plastic panel safety-return valve.
-
The body consists of a steel reservoir (water tank) and housing (outer shell) with thermal insulation placed in-between made of ecologically clean high density polyurethane foam, and two pipes with thread G ½ ‘’ for cold water supply (marked by a blue ring) and hot water outlet pipe (marked by a red ring).
The inner tank may be of two types depending on the model:
• Made of steel protected form corrosion by a special glass-ceramics coating
• Made of stainless steel
The vertical water heaters may be outfitted with a built in heat exchange unit (serpentine tube). The heat exchenger’s entrance and exit are located at the sides and represent pipes with thread G ¾ ‘’. -
The flange is outfitted with: electric heater and thermostat. The water heaters with glass-ceramics coating are outfitted with a magnesium protector.
The electric heater is used for heating the water in the tank and is managed by the thermostat, which automatically maintains the set temperature.
The thermostat has a built in overheating safety device, which switches of power to the heater when the water temperature reaches excessive values. -
The safety-return valve prevents the appliance’s complete emptying in the event the cold water supply is interrupted. The valve protects the appliance from pressure increases higher than the allowed value during heating (! pressure increases upon an increase of temperature), via release of excess pressure during the drainage opening.
The safety-return valve cannot protect the appliance in the event of water mains pressure in excess of the acceptable pressure stated for the appliance.
MOUNTING AND SWITCHING ON
Attention! Improper installation and connection of the appliance may make it hazardous for the health and life of consumers. It may cause grievous and permanent consequences, including but not limited to physical injuries and/or death. Improper installation and connection of the appliance may also lead to damage to the consumers’ property /damage and/ or destruction/, or to that of third persons, as a result of, but not limited to flooding, explosion and/or fire. Installation, connection to the main water and power supply, and putting into operation must be carried out by certified electricians and technical personnel certified in installation of this category of appliances, who have obtained their license in the state where the installation and commissioning of the appliance are carried out, and in compliance with its local legislation.
Notice: The installation of the unit is at the buyer’s expense.
1. Mounting
We recommend the mounting of the device at close proximity to locations where
hot water is used, in order to reduce heat losses during transportation. In
the event the device is mounted in a bathroom, the selected location must
exclude the possibility of water spray contact from the showerhead or portable
showerhead attachment.
The appliance is affixed to a wall via the mounting brackets attached to the
unit’s body (if the brackets are not attached to the unit’s body, they must be
affixed in place via the provided bolts). Two hooks are used for suspending
the appliance (min. Ø 10 mm) set firmly in the wall (not included in the
mounting set). The mounting bracket’s construction designed for water heaters
intended for vertical mounting is universal and allows a distance between the
hooks of 220 to 310 mm (fig. 1a). For water heaters intended for horizontal
mounting, the distances between the hooks vary for the different models and
are specified in the table 2 to Fig. 1b.
In order to prevent injury to user and third persons in the event of faults in
the system for providing hot water, the appliance must be mounted in premises
outfitted with floor hydro insulation and plumbing drainage. Don’t place
objects, which are not waterproof under the appliance under any circumstances.
In the event of mounting the appliance in premises not outfitted with floor
hydro insulation, a protective tub with a plumbing drainage must be placed
under the appliance.
Notice: the set does not include a protective tub and the user must
select the same.
2. Water heater connection to the pipe network.
Fig. 4:
Where: 1 – Inlet pipe; 2 – Safety valve; 3 – reducing valve (for water main
pressure > 0,6 MPa); 4 – Stop valve; 5 – Funnel connected to the sewer
network; 6 – Hose; 7 – Drain water tap.
Upon connecting the water heater to the water mains you must consider the
indicative color markings /rings/ affixed to the pipes: blue for cold
/incoming/ water,red for hot /outgoing/ water.
The mounting of the safety return-valve supplied with the water heater is
obligatory.
The safety return-valve must be mounted on the cold water supply pipe, in
observance of the direction arrow stamped on its body, indicating the incoming
water’s direction. Additional stopcocks must not be mounted between the safety
return-valve and the water heater.
Exception: If the local regulations (norms) require the usage of another
protection valve or mechanism (in accordance with EN 1487 or EN 1489), then it
must be bought additionally. For mechanisms operating in accordance with EN
1487 the announced operational pressure must be no more than 0.7 MPa. For
other protection valves, the pressure at which they are calibrated must be 0.1
MPa lower than the one marked on the appliance’s sign. In these cases the
safety valve which the appliance is supplied with should not be used.
The presence of other /old/ safety return-valves may lead to a breakdown of
your appliance and they must be removed.
Other type of stopping armature is not allowed between the protection return
valve (the protective device) and the appliance.
The attaching of the safety return-valve to threads longer than 10 mm is not
allowed, otherwise this may damage the valve and poses danger for your
appliance.
With ppliances for vertical assembly, the safety valve has to be connected to
the ingoing pipe with the safety plastic panel of the appliance being taken
off.
After it has been assembled it should be in position as shown on Fig. 2.
The safety valve and the pipe between the valve and the water heater must be
protected from freezing. During hose draining – its free end must be always
open to the atmosphere (not to be immersed). Make sure that the hose is also
protected from freezing.
Opening the cold-water stopcock of the water supply piping network and opening
the hot-water stopcock of the water-mixing faucet carries out the filling of
the water heater with water. After the filling is complete, a constant stream
of water must begin to flow from the water-mixing faucet. Now you can close
the hot water stopcock.
In the event you must empty the water heater, first you must cut off its power
supply. The inflow of water from the water mains must first be terminated and
the hot water tap of the mixing-faucet must be opened. The water tap 7 (fig.4)
must be opened to drain the water from water tank. If there is no such tap
build in the pipe line, than the water can be drain directly from inlet pipe
of water tank after when you disconnect it from water main.
In the event of removing the flange, the discharge of several liters of water,
which remain in the water tank, is normal.
Measures must be undertaken to prevent damage from discharging water during
draining
In case that the pressure in the water mains is over the value pointed out in
the above paragraph II, then it is necessary to assemble a pressure reduce
valve, otherwise the water heater would not function properly. The
Manufacturer does not assume any liability for problems arising out of the
appliance’s improper use.
3. Water heater connection to the electrical network
Make sure the appliance is full of water prior to switching on the electrical
mains power.
3.1. Models with power cord with a plug are connected by inserting the plug
into a contact. They are switched off the power supply by drawing the plug out
of the contact.
The wall-plug must be properly connected to a separate electrical circle that
is provided with a protector. It must be earthed.
3.2. The appliance has to be connected to a separate electricity circuit of the stationary electrical wiring. The connecting has to be constant- with no plug contacts. The circuit has to be supplied with a safety fuse (16A) and with inbuilt device to ensure disconnection of all pole pieces in the conditions of over-voltage from category III.
The connecting of the conductors of the supply cord of the appliance has to be carried out as follows:
- conductor with brown insulation – to the phase conductor of the electrical wiring (L)
- conductor with blue insulation- to the neutral conductor of the wiring (N)
- conductor with yellow-green insulation – to the safety conductor of the wiring
3.3. Models without power cord
The appliance has to be connected to a separate electricity circuit of the
stationary electrical wiring. The circuit has to be supplied with a safety
fuse 16A (20A for power > 3700W). Copper single core (rigid – non stranded)
conductor shall be used for the connection – cable 3 x 2.5 mm² (cable 3 x 2.5
mm² for power > 3700W).
The electrical circuit supplying the appliance must have an in-built device
ensuring the splitting of all terminal poles under conditions of super-voltage
of category III.
To install the power supply wire to the appliances remove the plastic cover.
Connect the power wires in compliance with the marks on the terminals, as
follows:
- the phase – to mark A, A1, L or L1;
- the neutral – to N (B or B1 or N1)
- The safety wire must be obligatory connected to the screw joint marked with
After the installation, put the plastic cover back in its place!
Explanations to Fig. 3:
T2 – thermal switch; T1 – thermal regulator; S – switch; R – heater; SL1, SL2,
SL3 – light indicator; F – flange.
RUST PROTECTION MAGNESIUM ANODE
The magnesium anode protects the water tank’s inner surface from corrosion.
The anode element is an element undergoing wear and tear and is subject to
periodic replacement.
In view of the long-term and accident free use of your water heater, the
manufacturer recommends periodic inspections of the magnesium anode’s
condition by a qualified technician and replacement whenever required, and
thiscould be performed during the appliance’s technical preventive
maintenance.
For replacements, please contact the authorized service stations!
OPERATION
-
Switch on:
Before switching on the appliance for first time, make sure that the water heater is properly connected to the power supply network and full with water.
The appliance is switched on by a switch integrated into the installation, described in item 3.3 of Section IV, or upon connecting the plug to the electrical contact (in the case of an extension cable with plug). -
Water heaters with electromechanical control
Fig. 2 shows:
1 – Thermal regulator
2 – Power switch
3 – Indicator lights
Thermal regulator (1) and indicator light for „heating up / ready to use“
Setting of the temperature is provided by a knob for the thermal regulator
(1). This setting allows for gradual adjustment to the desired temperature.
Fig.2 displays the rotation direction of the knobs.
e ENERGY SAVING – in this mode the water in the appliance is at a temperature
of approximately 60°С. Thus thermal loss is reduced.
Indicator light “heating up / ready to use“
– indicates the status/operation mode of the appliance: the light is red while
the water is heated and it is blue when the water has reachedthe temperature
as set by the thermostat. The light is off when the power switch is in off
position.
Power switch (2) and indicator lights
Single-level power switch:
0 – power is off;
I – power is on;
The power indicator light for I is on when the switch is turned on at level I.
Power switch with two levels:
0 – power is off;
I, II – power is on;
Selection of levels of heating power:
Rated power (as marked on the nameplate of the appliance )|
Switched to
level (I)| Switched to
level (II)
---|---|---
1200 W| 600 W| 1200 W
1600 W| 800 W| 1600 W
2400 W| 1200 W| 2400 W
At level I of the switch, the power indicator light I is on.
At level II of the switch both power indicator lights I and II are on.
3. Protection according to the temperature (valid for all models)
The appliance is equipped with a special facility (thermal circuit-breaker)
for protection against over-heating of the water, which is switching off the
heater from the electricity
network, when the temperature reaches too high values.
When this device operates, it does not self-reset and the appliance will not
work. Please call an authorized service for solving the problem.
MODELS EQUIPPED WITH A HEAT EXCHANGER (SERPENTINE TUBE) – FIG.1C, FIG.1D,
FIG.1E AND TABLES 3 ÷ 5
These are appliances with inbuilt heat exchanger and are intended to be
connected to the heating system with maximum temperature of the heat carrier
of 80°C. The control over the flow through the heat exchanger is a matter of
solution for the particular installation, whereby the choice should be made at
its design (e.g. external thermostat that measures the temperature in the
water tank and operates a circulation pump or a magnet valve).
Water heaters with a heat exchanger provide the opportunity for the water to
be heated in two ways:
- by means of a heat exchanger (coil) – a primary way of heating the water,
- by means of an auxiliary electrical heating element with automatic operation, built in the appliance – it is used only when additional heating of the water is needed or in case of repairs to the system of the heat exchanger (coil). The proper way of connecting the appliance to the electric network and how to work with it has been specified in the previous paragraphs.
Mounting
In addition to the mounting manner outlined above, especially for the latter
models, it shall be required to connect the heat exchanger to the heating
installation. The connections are to be carried out in observance of the
direction indicated by the arrows on Fig. 1c, 1d, 1e. We recommend you mount
stopcocks at the heat exchanger’s entry and exit points. By stopping the flow
of the thermophore via the lower (stopcock) you shall avoid the unnecessary
circulation of the thermophore during periods of use only of the electric
heating element.
Upon disassembly of you water heater equipped with a heat exchanger you must
close both stopcocks.
The usage of dielectric bushings for connecting the heat exchanger to an
installation of copper pipes is obligatory.
For ensuring minimal corrosion, pipes with a limited diffusion of gasses must
be used in the installation.
Models with a single heat exchanger and a thermal sensor pocket
Appliance installation is responsibility of the customer hence a qualified
installation technician has to perform it in accordance with the main user
guide and the present appendix thereto.
Technical parameters:
Type| GCV6S
8047| GCV9S
10047| GCV9S
12047| GCV9S
15047| GCV11SO
15047
---|---|---|---|---|---
Surface of the serpentine (m²)| 0.45| 0.7| 0.7| 0.7| 0.83
Volume of the serpentine (l)| 2.16| 3.23| 3.23| 3.23| 3.88
Operational pressure of the serpentine (MPa)| 0.6| 0.6| 0.6| 0.6| 0.6
Maximum temperature of the heat carrier (°C)| 80| 80| 80| 80| 80
For models with a possibility for installation of the thermal sensor pocket,
delivered along with the appliance, it has to be installed where the „TS“
lead-in is. The thread needs to be tightened.
Models with two heat exchangers and a thermal sensor pocket
These models allow for connection to two external heat sources – a solar panel
and local or central water heating supply.
Serpentine markings:
- S1 and an arrow pointing at the serpentine lead-in – inlet of serpentine S1
- S1 and an arrow pointing outwards from the serpentine lead-in – outlet of serpentine S1
- S2 and an arrow pointing at the serpentine lead – inlet of serpentine S2
- S2 and an arrow pointing outwards from the serpentine lead-in – outlet of serpentine S2
There is a connexion with internal thread of ½” welded to the water tank for the purposes of installing thermal probe – marked with ‘TS”. The appliance is fitted with brass pocket for a thermal probe which should be screwed into the aforesaid connexion.
Technical parameters:
Type| GCV7/4S
10047| GCV7/4S
12047| GCV7/4S
15047
---|---|---|---
Surface of serpentine S1 (m²)| 0.5| 0.5| 0.5
Surface of serpentine S2 (m²)| 0.3| 0.3| 0.3
Volume of serpentine S1 (l)| 2.4| 2.4| 2.4
Volume of serpentine S2 (l)| 1.4| 1.4| 1.4
Operational pressure of serpentine S1 (MPa)| 0.6| 0.6| 0.6
Operational pressure of serpentine S2 (MPa)| 0.6| 0.6| 0.6
Maximum temperature of heat carrier (°C)| 80| 80| 80
PERIODIC MAINTENANCE
Under normal use of the heater, under the influence of high temperature, lime
scale /the so-called lime scale layer/ is deposited upon the heating element’s
surface. This worsens the heat exchange between the heating element and water.
The heating element’s surface temperature increases along /of boiling water/.
The thermoregulator begins to switch on and off more frequently. A
‘’deceptive” activation of the thermal protection is possible. Due to these
facts, the manufacturer recommends preventive maintenance of your water heater
every two years by an authorized service center or service base. This
protective maintenance must include cleaning and inspection of the anode
protector (for water heaters with glass-ceramic coating), which shall be
replace with a new one if need arises.
In order to clean the appliances use a damp cloth. Do not clean with abrasive
or solvent content detergents. Do not pour water over the appliance.
The manufacturer does not bare the responsibility for all consequences
caused by not obeying the instructions, given hereby.
Instructions for protecting the environment
Old electric appliances contain precious materials and thus should not be
thrown together with the household litter. We kindly ask you make your active
contribution for protecting the resources and the environment by handing over
the appliance in the authorized buyback stations (if such exist).
Type | D, mm | H, mm | B, mm | C, mm | E, mm |
---|---|---|---|---|---|
GCV 5047.. | 470 | 600 | 496 | 139 | 202 |
GCV 8047.. | 470 | 850 | 496 | 139 | 202 |
GCV 10047.. | 470 | 990 | 496 | 139 | 202 |
GCV 12047.. | 470 | 1155 | 496 | 139 | 202 |
GCV 15047.. | 470 | 1320 | 496 | 139 | 202 |
Type | D, mm | H, mm | A, mm | B, mm | E, mm |
---|---|---|---|---|---|
GCH 8044.. / GCHL 8044.. | 470 | 850 | 407 | 496 | 177 |
GCH 10044.. / GCHL 10044.. | 470 | 990 | 552 | 496 | 177 |
GCH 12044.. / GCHL 12044.. | 470 | 1155 | 702 | 496 | 177 |
GCH 15044.. / GCHL 15044.. | 470 | 1320 | 927 | 496 | 177 |
Type| D, mm| H, mm| A, mm| B, mm| E, mm| L,
mm| F, mm
---|---|---|---|---|---|---|---
GCHS 8044..| 470| 850| 407| 496| 177| 360| 243
GCHS 10044..| 470| 990| 552| 496| 177| 480| 243
GCHS 12044..| 470| 1155| 702| 496| 177| 480| 243
Type| D, [mm]| H, [mm]| L, [mm| F, [mm| B, mm|
E, mm| K, mm
---|---|---|---|---|---|---|---
GCV6S 8047../GCV6SL 8047..| 470| 850| 295| 243| 496| 202| 120
GCV9S 10047../GCV9SL 10047..| 470| 990| 445| 243| 496| 202| 120
GCV9S 12047../GCV9SL 12047..| 470| 1155| 445| 243| 496| 202| 120
GCV9S 15047../GCV9SL 15047..| 470| 1320| 445| 243| 496| 202| 120
GCV11SO 15047../GCV11SLO 15047..| 470| 1320| 565| 243| 496| 202| 130
Type | D, mm | H, mm | B, mm | E, mm |
---|---|---|---|---|
GCV7/4S 10047../GCV7/4SL 10047.. | 470 | 990 | 496 | 202 |
GCV7/4S 12047../GCV7/4SL 12047.. | 470 | 1155 | 496 | 202 |
GCV7/4S 15047../GCV7/4SL 15047.. | 470 | 1320 | 496 | 202 |
![TESY 10047, 12047, 15047 Electric Water Heater
- 8](https://manuals.plus/wp-content/uploads/2023/01/TESY-10047-12047-15047 -Electric-Water-Heater-8.png)
TESY Ltd
Shumen, 9700, 48 Blvd. Madara,
PHONE: +359 54 859 129,
office@tesy.com