Specifications

Inlet Water Temperature Maximum: 60°C
Dynamic Water Pressure ![BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG

2](https://manuals.plus/wp-content/uploads/2022/12/BRISTAN-MI-3-4-BLK-Mila- Black-Bath-Pillar-Taps-FIG-2.png)| Maximum Static Pressure: 10.0 bar
Inlet Connections| |

Tools You’ll Need

BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 4

Prior to Installation

All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions. This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future maintenance.
Before installing this product the water supply must be thoroughly flushed in order to remove any swarf, solder etc. Full access must be made available for future  aintenance/
servicing purposes.
This product must not be modified in any way as this will invalidate the guarantee. If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane, Hornchurch, Essex,
RM12 6NB, Tel: 01708 472791

Pack Contents

BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 5

Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product.http://www.bristan.com/products/kitchen-taps?code=GLL%20PROSNK%20C

Installation

  1. Fit the taps to the bath, ensuring the plinth are in place.
    BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 6

  2. Secure the taps to the bath by using the washer and metal backnut below the bath.
    BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 7

  3. Connect the hot and cold water supplies to the threaded tails.
    BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 8

Operation

BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 9

Maintenance – Clean/Replace Outlet

  1. Using outlet key (not included), unscrew gently to remove the outlet.BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 10
  2. Check for damage.  Soak using a suitable solution to de-scale.

BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 11.Screw back into the tap body to replace the outlet.

General Cleaning

Bristan products are made from premium materials, with hand polishing and electroplated finishes.
Your taps or shower should be regularlycleaned with warm water, a mild pH- neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on spouts..

Maintenance – Valve Cleaning

  1. Unscrew handle lever and pull of handle.BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 12
  2. Unscrew the valve using an adjustable spanner. Check any seals and O-rings for damage. Replace valve if necessary.BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 13
  3. Place valves in a suitable solution and soak until fully de-scaled. BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 15
  4. Reverse the steps to replace the valves and handles.BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG 14

Troubleshooting

Symptom Cause Remedy

No flow or low flow
rate| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to specification for minimum distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or instantaneous boiler temperature changes.| Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to ensure removal of debris and any airlocks.
Water dripping from taps| This is normal for a short time after using the taps.| This is caused by residual water tension, the build up of water in the tap body.
If water continues to drip, possibly due to the ceramic disc valves| Remove valves and clean, refer to ‘Maintenance’ section before starting any maintenance.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.

Contact Us
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l.
14 Rue Strachen 6933 Mensdorf ,Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company

Our Guarantee

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service- centre/guarantees.

https://www.bristan.com/service-centre/guarantees

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRISTAN User Manuals

Related Manuals