BRISTAN MI 3/4 BLK Mila Black Bath Pillar Taps Installation Guide
- June 2, 2024
- BRISTAN
Table of Contents
- MI 3/4 BLK Mila Black Bath Pillar Taps
- Specifications
- Tools You’ll Need
- Prior to Installation
- Pack Contents
- Installation
- Operation
- Maintenance – Clean/Replace Outlet
- General Cleaning
- Maintenance – Valve Cleaning
- Troubleshooting
- Our Guarantee
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MI
3/4 BLK Mila Black Bath Pillar Taps
Installation Guide
MI 3/4 BLK Mila Black Bath Pillar Taps
Product Code: MI 3/4 BLK (D2)
Installation Instructions & User Guide
Please leave these instructions with the end user
Specifications
Inlet Water Temperature | Maximum: 60°C | |
---|---|---|
Dynamic Water Pressure | ![BRISTAN MI 3 4 BLK Mila Black Bath Pillar Taps FIG |
2](https://manuals.plus/wp-content/uploads/2022/12/BRISTAN-MI-3-4-BLK-Mila-
Black-Bath-Pillar-Taps-FIG-2.png)| Maximum Static Pressure: 10.0 bar
Inlet Connections| |
Tools You’ll Need
Prior to Installation
All products manufactured and supplied by Bristan are safe to use provided
that they are installed, operated and receive regular maintenance in
accordance with these instructions. This product needs to be installed in
accordance with, and meet the requirements of the Water Supply (Water
Fittings) Regulations 1999 and current by-laws. For full Installation
Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc. Full access must be made available for
future aintenance/
servicing purposes.
This product must not be modified in any way as this will invalidate the
guarantee. If in doubt, contact a registered plumber, your Local Water
Authority or the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane, Hornchurch, Essex,
RM12 6NB, Tel: 01708 472791
Pack Contents
Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit
www.bristan.com and search for your
product.http://www.bristan.com/products/kitchen-taps?code=GLL%20PROSNK%20C
Installation
-
Fit the taps to the bath, ensuring the plinth are in place.
-
Secure the taps to the bath by using the washer and metal backnut below the bath.
-
Connect the hot and cold water supplies to the threaded tails.
Operation
Maintenance – Clean/Replace Outlet
- Using outlet key (not included), unscrew gently to remove the outlet.
- Check for damage. Soak using a suitable solution to de-scale.
Screw back into the tap body to replace the outlet.
General Cleaning
Bristan products are made from premium materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularlycleaned with warm water, a mild pH-
neutral liquid soap, and polished with a soft cloth. Any residues from soap,
toothpaste, shampoos and shower gels can cause blemishes if not rinsed off
straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the
surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges,
steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in
some cloths, so it is also important to avoid hanging cloths on spouts..
Maintenance – Valve Cleaning
- Unscrew handle lever and pull of handle.
- Unscrew the valve using an adjustable spanner. Check any seals and O-rings for damage. Replace valve if necessary.
- Place valves in a suitable solution and soak until fully de-scaled.
- Reverse the steps to replace the valves and handles.
Troubleshooting
Symptom | Cause | Remedy |
---|
No flow or low flow
rate| Partially closed isolation valve.| Open isolation valve.
Instantaneous water heater cycles on and off as flow rate or pressure is too
low.| Increase water flow rate or pressure through system.
Head of water is below the minimum distance required.| Refer to specification
for minimum distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework.| Flush through pipework to
ensure removal of debris and any airlocks.
Water dripping from taps| This is normal for a short time after using the
taps.| This is caused by residual water tension, the build up of water in the
tap body.
If water continues to drip, possibly due to the ceramic disc valves| Remove
valves and clean, refer to ‘Maintenance’ section before starting any
maintenance.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
Contact Us
Bristan Group Ltd.
UK: Bristan Group, B78 1SG.
EU: Masco Europe S.à.r.l.
14 Rue Strachen 6933 Mensdorf ,Luxembourg
Customer Service: +44330 026 6273
Web: www.bristan.com
Email: enquire@bristan.com
A Masco Company
Our Guarantee
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind. To start your free guarantee
simply scan the QR code and register your product.
Alternatively visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit www.bristan.com/service-
centre/guarantees.
https://www.bristan.com/service-centre/guarantees
References
- ekat.com - Dichtungen, Schläuche, Gummi und Kunststoff
- Water Regulations Approval Scheme Ltd - Approvals Directory
- Home
- Register a product
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>