BRISTAN RSP EFSNK BLK D1 EasyFit Sink Mixer Tap Installation Guide
- May 15, 2024
- BRISTAN
Table of Contents
Installation Instructions & User Guide
Please leave these instructions
with the end user
Product Code: RSP EFSNK BLK (D1)
Specifications
Inlet Water Temperature Maximum: 65°C
Dynamic Water Pressure Maximum Static Pressure: 10.0 bar
Inlet Connections
1/2” BSP Flexible Tails with Isolation Valves
Non-Return Valves Included
Tools You’ll Need
Servicing Your Tap
We recommend servicing your tap at least once every year to prolong its
life. To see a video showing how to remove the cartridge for servicing, scan
the QR code with your smart phone or tablet.
Alternatively visit www.youtube.com/BristanTV
Prior to Installation
All products manufactured and supplied by Bristan are safe provided they are
installed, used correctly and receive regular maintenance in accordance with
these instructions.
This product has been tested to the Water Regulations Advisory Scheme (WRAS)
and satisfies the requirements of the Water Supply (Water Fittings)
Regulations 1999 and current bylaws.
For full Installation Requirements & Notes (IRN) please visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of
future maintenance.
Before installing these taps the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Flexible Connecting Pipes
Pack Contents
Spare Parts
To replace any spare parts for your tap, why not scan the QR Code or visit www.bristan.com and search for your product.
Installation
Feed the base through the sink hole from the top.If the surface the tap is being fitted to is over 8mm; or you feel the tap needs extra stability, follow the alternative installation steps overleaf.
Turn the hexagonal key clockwise until the base is secured.
Grease the O-Rings using the Molykote Grease provided.
Place your desired tap onto the base.
Secure in place with the grub screws using the tool provided.
Thread the hexagonal key through the EasyFit tool and tighten the grub screws with an extra 1/2 turn.
Your tap is now ready to use.
General Cleaning
Bristan products are made from premium materials, with hand polishing and
electroplated finishes.
Your taps or shower should be regularly cleaned with warm water, a mild pH-
neutral liquid soap, and polished with a soft cloth. Any residues from soap,
toiletries etc. should be rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the
surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges,
steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in
some cloths, so it is also important to avoid hanging cloths on spouts.
Alternative Installation for Surfaces Out of Tolerance/Extra Stability
Turn the hexagonal key anti-clockwise to remove the back nut from the EasyFit Base.
Feed the base through the sink hole from the top.| Feed the Reinforcing Plate, (if required) and Back nut up to the underside of the sink.
Turn the hexagonal key clockwise to secure the EasyFit Base.
Proceed to Step 4 of the Installation Steps.
Love Your Chrome
http://www.bristan.com/search?query=clean%20kit01
Bristan offers an effective chrome-friendly cleaning kit for use with your
taps and showers.
Scan the QR Code or search for ‘CLEAN KIT01’ on
www.bristan.com.
Maintenance – Cleaning/Replacing Outlet
Remove using the key provided or a coin if not available.
Clean and replace as necessary. Secure the anti-splash.
Turn on the mains water supply, letting the water flow for a few minutes to flush through the system.
Maintenance – Removing/Replacing Cartridge
Turn on the mains water supply, letting the water flow for a few minutes to flush through the system.
Troubleshooting
Symptom | Cause(s) | Remedy |
---|---|---|
No flow or low flow rate | Partially closed isolation valve. | Open isolation |
valve.
Head of water is below the minimum distance required.| Refer to your the
Specification for the minimum working pressure/ distance required.
Hot or cold water being drawn off elsewhere causing pressure changes or
instantaneous boiler temperature changes.| Do not use other water outlets when
using the taps.
Airlock or partial blockage in the supply pipework or hoses.| Flush through
pipework to ensure removal of debris and any airlocks.
Water supply failure| Investigate water supply. Check your plumbing and
heating systems for any faults.
Water dripping from
taps| This is normal for a short time after using the taps.| This is caused by
residual water tension, the build up of water in the tap body.
If water continues to drip, possibly due to the ceramic disc valves/cartridge|
Refer to the Maintenance section or visit www.youtube.com/BristanTV to watch
the procedure.
Taps do not turn on| Closed isolation valve.| Open isolation valve.
Mains water supply turned off.| Turn on mains water supply.
Wobbly Tap| Grub screws are not tight enough at the base| Ensure the grub
screws are fully tightened against the base
Extra security may be required depending on the surface the tap is fitted on
to.| Refer to the Alternative Installation steps in order to fit the
Reinforcing Plate.
At Bristan, we want to make things as easy as possible for our customers.
That’s why we offer solid guarantees on all our products, effective from the
date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your
product.
Alternatively visit
www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where
our expert team of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit
www.bristan.com/guarantees.
We Know & We Care
http://www.bristan.com//register
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>