Bristan WMNT12 Bar Showers with Wallmount 12 Fixing Kit Installation Guide

May 15, 2024
BRISTAN

WMNT12 Bar Showers with Wallmount 12 Fixing Kit

Specifications:

  • Dynamic Water Pressure:
    • Min: 1.0 bar
    • Max: 5.0 bar
  • Maximum Static Pressure: 10.0 bar
  • Inlet Water Temperature: DIV SHXDIVCTFF C (D1)
  • Inlet Connections: 1/2 Compression
  • Inlet Dimensions: 150mm Centres

Product Usage Instructions:

Prior to Installation:

All products by Bristan are safe to use if installed, operated,
and maintained as per the instructions. Ensure compliance with
relevant regulations.

Installation Requirements:

Before installation, flush the water supply thoroughly. Provide
full access for maintenance and fit isolation valves for future
maintenance ease.

Precautions:

  • Check for hidden wires, cables, or pipes before drilling into
    walls using an electronic detector.

  • When using power tools, wear eye protection and unplug
    equipment after use.

Servicing and Spare Parts:

Contact Customer Services at 0330 026 6273 for spare parts. Do
not modify the product to maintain the guarantee.

FAQ:

Q: Are Bristan products safe to use?

A: Yes, all Bristan products are safe to use when installed and
maintained correctly according to the provided instructions.

Q: What should I do before installing the product?

A: Before installation, ensure a thorough flushing of the water
supply, provide access for maintenance, and fit isolation valves
for ease of future maintenance.

Installation Instructions & User Guide
Please leave these instructions with the end user

Dynamic Water Pressure

Min: 1.0 bar

Max: 5.0 bar

2.0 3.0

1.0

4.0

0 5.0
Pressure BAR

Maximum Static Pressure: 10.0 bar
Tools Required

Specifications
Inlet Water Temperature

25°C 5°C

65°C 60°C

Min 5°C; Max 25°C
IMPORTANT
The inlet hot water must be at least 10°C above the required blend temperature.

Recommended 60°C; Max 65°C
Factory pre-set 38°C

DIV SHXDIVCTFF C (D1)
Inlet Connections
1/2″ Compression
Inlet Dimensions
150mm Centres

Pencil

Flat head Screwdriver

Drill

Pack Contents

Cross head Screwdriver

Spanner

Operation

Pipe Cutter

Hexagonal Keys

Socket Spanner

Cold

x1 x1
x1 x2

x1

x2

x2 x1

x1

x1

x1

x1
x2 x2

x2 x2 x2
x2 x8

On –

Hot

x8
x1
x1
Prior to Installation

On Handset

Spares

All products manufactured and supplied by Bristan are safe to use provided that they are installed,

operated and receive regular maintenance in accordance with these instructions.

This product needs to be installed in accordance with, and meet the requirements of The

Water Supply (Water Fittings) Regulations (Northern Ireland) 2009 and The Water Supply (Water Fittings)

(Scotland) Byelaws 2014. For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.

co.uk/approvals-directory

Before installing this product the water supply must be thoroughly flushed in order to remove any swarf,

solder etc. Full access must bemade available for future maintenance/servicing purposes. Isolation valves

must be fitted to the inlet water supplies to ensure ease of future maintenance.

Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This

can be checked with the aid of an electronic detector. If power tools are used do not forget to:

– Wear eye protection

– Unplug equipment after use

To replace any spare parts for your product, please contact our Customer Services Department
on 0330 026 6273, where our team of expert advisors will be
happy to help.

This product must not be modified in any way as this will invalidate the guarantee.

Installation Instructions and User Guide
Bar Showers with Wallmount 12 Fixing Kit (WMNT12)
Please keep this booklet for future reference.
Installer, when you have read these instructions please ensure you leave
them with the user.

Contents
Thank you for choosing Bristan, the UK’s leading taps and showers expert. We have designed this product with your enjoyment in mind. To ensure that it works to its full potential, it needs to be fitted correctly. These fitting instructions have been created to give you all of the information you need and, if you need any further help, please do not hesitate to give us a call on 0330 026 6273.

Contents

· Important Safety Information

3

· Installation Requirements

4-6

· Installation

7

· Isolation

8

· Temperature Setting

8

· General Cleaning

9

· Notes

9

· Maintenance – Cartridege/Valve Cleaning

10

· Troubleshooting

11

2 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Important Safety Information

Please make sure you read these instructions and retain for future use. All products manufactured by Bristan are safe, providing they are installed and used correctly and also receive maintenance when needed.

These fittings, including the connecting water and waste system need to be installed in accordance with and meet the requirements of the Water Supply Regulations 1999 (Water Fittings) and current by-laws. If you are in doubt about your ability to install this product correctly or safely, you should employ the services of an experienced qualified plumber.

This product must not be modified in any way otherwise this will invalidate the guarantee. Remove all packaging and check the contents for damage before starting installation.

Warning:

Before installing the new mixer valve it is essential that you thoroughly flush through the pipework in order to remove any remaining swarf, solder, etc. Failure to carry out this procedure could cause problems or damage to the workings of the mixer tap.

Fitting isolating valves to the inlet feeds is required for ease of maintenance.

Warning:

Do not operate the mixer if you suspect it is frozen. Do not site the mixer valve where it might be subjected to freezing conditions.
Consider the following whilst using power tools:

·

Prior to drilling into walls, check there are no hidden electrical cables or

wires and there are also no water pipes. These can potentially be found

using an electrical or metal detector. You may also need to know some

of the schematics of previous installations to determine the suitability

and accommodation of the installation.

·

Wear the correct PPE, especially ear, eye and hand protection

when using power tools. Unplug any mains equipment after use.

·

Keep electrical equipment away from sources of water.

·

If a blow-lamp is used when plumbing, the flame must be kept well away from

the product otherwise damage may occur.

If in doubt, contact a registered plumber, your Local Water Authority or the Secretary of The Institute of Plumbing, address as follows;-
The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB Tel:01708 472791

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 3

Installation Requirements

Please refer to your specific shower contents page for specification information.
These showers are designed to be used in conjunction with the kit supplied, or Bristan shower kits where not supplied. We cannot guarantee compatability or adequate performance when used with other kits. This would also invalidate your guarantee. Please refer to the installation manual supplied with your Bristan shower kits for their specification information.
This shower valve must be installed in compliance with current water regulations. If you have any doubts about the water regulation requirements contact your local water services provider or use the services of a professional plumber.

This shower valve is suitable for use with the following water supply systems:
· Gravity Fed Hot and Cold (pressure imbalance should not exceed a ratio of 5:1 – see Specification section)
· Gravity Fed Hot and Mains Cold (pressure imbalance should not exceed a ratio of 5:1 – see Specification section)
· Instantaneous water heater (combination boiler)
· Unvented System
· Pumped System
Important: If you install this shower valve with a gravity fed system, there must be a minimum head (vertical distance) from the underside of the cold water storage tank to the outlet of at least 1 metre for every 0.1 bar of minimum pressure required.
Note: Pumped system (with Essex flange) If you install this shower valve to a pumped gravity fed system where the minimum head (vertical distance) from the underside of the cold water storage tank to the top of the hot water cylinder is less than 1 metre we recommend an Essex flange is used as shown.
Flushing Pipe-work
Important: Before connecting the shower valve (see `Installation’ on page 7), the supply pipe-work must be flushed to clear debris before connecting the shower. Debris will reduce the performance and life of the bar shower and Wall Mount.

4 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Installation Requirements

Gravity Fed Hot and Cold

Gravity Fed Hot and Mains Cold

1m min.

1m min.

cold mains supply

Key:

Isolating Valve

Reducing Valve

cold mains supply

Shower Valve

Pump

Essex Flange

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 5

Installation Requirements

Instantaneous Water Heater

Unvented System

cold mains supply
Pumped System

cold mains supply
Pumped System (with Essex flange)

1m min.

If less than 1m see note.
50mm

1m min.

cold mains supply

cold mains supply

Key:

Isolating Valve

Reducing Valve

Shower Valve

Pump

Essex Flange

6 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Installation

PLEASE NOTE – Wall Mounts shown in these instructions are for illustration purposes only. WMNT12 and WMNT12 SQ can be fitted using these instructions.

1
Identify the required position of the valve and prepare the water supply pipes. Supply pipes should be
150mm apart.
Using the rubber fixing plate supplied with the wall mount, mark and
drill holes.
3

2

150mm Centres
4

hocRotElodMnEotnMheBthEleeRft, right

21mm

Secure the rubber backplate and backplate into place.

5

Secure the isolator onto the backplate ensuring the olive is positioned over the pipework correctly.

Push shrouds to the back of the wall outlet, securing them against the rubber fixing plate.

RTEoMsEerMvBicEeR your
product!

Secure the shower to the wall mount.

Now refer to your kit instructions to install your shower kit if supplied. If your shower is TMV approved, please refer to the TMV manual supplied to commision your shower.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 7

Isolation

1

2

Remove the concealing cap from the shroud.

Rotate the shroud until the opening
aligns with the isolation screw. Turn the screw
to isolate the water. Reverse the process when turning the water
back on.

PLEASE NOTE – Wall Mounts shown in these instructions are for illustration purposes only. WMNT12 and WMNT12 SQ can be fitted following these instructions. Check your contents page for more details specific to your shower.

Temperature Setting

1

2

3

Turn flow handle to

4

`on’ position, letting

the temperature

stabilise.

12

Turn the temperature handle to the max. setting and remove the temperature handle.

Turn cartridge spindle clockwise to decrease the temperature.
Turn cartridge spindle anti-clockwise to increase the
temperature.

PLEASE NOTE – Bar showers shown in these instructions are for illustration purposes only. All bar showers can be fitted/maintained following these instructions. Check your contents page for more details specific to your shower.

Reverse steps 1-2 to reinstall the cartridge
and handle.
IMPORTANT 4tTth1eMc°emoCVsmphasIepfoshrltwoapyshwtceeewuhrrermeirwTetsmhMaiilasxeltVrhi .nimeneoscptuTralrmoeMnean-dVsgsaeeerdtrdtso.

8 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

General Cleaning
Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes. Your bar shower should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use. Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar. Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on fittings/barshowers etc.
Notes
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 9

Maintenance – Cartridge/Valve Cleaning

PLEASE NOTE – Bar showers shown in these instructions are for illustration purposes only. All bar showers can be fitted/maintained following these instructions.

1

2

DEPENDING ON YOUR SHOWER TYPE:
Remove the

3

Remove adaptor, nut and

cartridge retaining

cartridge. Depending

nut and diverter

on your shower you may

cartridge

need a specific cartridge

tool (not supplied), or

check for the grub screw

OR

underneath the bar valve

to remove

30mm

Remove temperature and flow handle.

Unscrew the flow valve.

4

Remove O-rings and soak all
components in de-scaler and wash off in clean water. Examine all seals and replace if
needed. Use WRAS approved silicon based grease on all seals.

5

Replace nut and temperature stop. Ensure the raised
side is facing towards the back of
the valve.

6
Turn cartridge spindle clockwise to decrease the temperature. Turn
cartridge spindle anti-clockwise to increase the temperature.
Servicing Intervals

7

Slide handle onto adaptor
and turn

clockwise

until you meet

resistance.

RTEoMsEerMvBicEeR your
product!
Spare Parts

8 12
Reverse steps 1-2 to reinstall the valve/ cartridge and secure handles. Refer to the `Temperature Setting’ maintenance steps to re-calibrate the max.
temperature.

To reduce the build up of limescale and to ensure this shower works to its maximum performance we recommend this shower is serviced every 6-12 months depending on the hardness of your water.

To replace any spare parts for your shower why not scan the below QR Code and search for your product.

10 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Troubleshooting

Symptom
No flow or low flow rate

Cause Partially closed isolation valve. Instantaneous water heater cycles on and off as flow rate or pressure is too low.
Head of water is below the minimum distance required.
Are the water supply pressures balanced?
Hot or cold water being drawn off elsewhere causing pressure changes or instan-
taneous boiler temperature changes. Airlock or partial blockage in the supply pipework.
Hot/Cold water supply has failed

Remedy Open isolation valve. Increase water flow rate or pressure through system. Refer to the specification for the minimum distance required. If pressures are unbalanced, a pressure reducing valve should be used for optimum performance.
Do not use other water outlets when using the shower.
Flush through pipework and filters to ensure removal of debris and any airlocks.
Check the hot and cold feeds. The shower will not work if either fails.

Maximum Water Temperature needs adjusting.

Refer to the Temperature Setting section to set your desired maximum temperature.

Outlet Water Temperature too Hot/Cold
Only hot/cold water from Shower
Valve
Water dripping
from shower
Shower does not turn on

Filter/pipe blockage Installation conditions outside
operating parameters. Hot water temperature is less than 10°C above the required blend temperature
Instantaneous water not igniting because the water flow rate is too low.
Instantaneous water not igniting because the water pressure is too low.
Inlet water supplies are reversed.
Filter/pipe blockage This is normal for a short time after
using the shower. If water continues to drip, possibly due to the cartridge
Closed isolation valve. Mains water supply turned off.

Flush through pipework and filters to ensure removal of debris and any airlocks.
Refer to the specification for the minimum distance required.
Adjust hot water temperature or wait for water to reheat if a stored water
system is used.
Increase water flow rate through the system. Refer to the Maintenance section to clean/
check the cartridge and filters for any damage. Contact your boiler manufacturer.
Refer to the specification for system requirements. Increase water pressure
through the system. Contact your boiler manufacturer.
Check the water inlet connections are the correct way around: Hot on the left, Cold on
the right when viewed from the front. Rework pipework as necessary.
Flush through pipework and filters to ensure removal of debris and any airlocks.
This is caused by residual water tension, the build up of water in the shower.
Remove cartridge and clean, refer to ‘Maintenance’ section before starting
any maintenance.
Open isolation valve.
Turn on mains water supply.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 11

Issue: D1 Part Number: Bar SHWR WMNT

Bristan Group Ltd.

UK: Bristan Group, B78 1SG. EU: Masco Europe S.à.r.l.
14 Rue Strachen 6933 Mensdorf Luxembourg

Customer Service: +44330 026 6273

Web:

www.bristan.com

Email:

enquire@bristan.com

A Masco Company

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.

Installation Instructions and User Guide
Rigid Riser & Telescopic Riser Kits
Please keep this booklet for future reference.
Installer, when you have read these instructions please ensure you leave
them with the user.

Contents
Thank you for choosing Bristan, the UK’s leading taps and showers expert. We have designed these products with your enjoyment in mind. To ensure that they work to their full potential, they need to be fitted correctly. These fitting instructions have been created to give you all of the information you need and, if you need any further help, please do not hesitate to give us a call on 0330 026 6273.

Contents

· Important Safety Information

3

· Prior to Installation

4

· Installation – Inline Diverter

5

· Installation – Rigid Risers

6-8

· Installation – Telescopic Round Risers

9

· Installation – Telescopic Square Risers

10

· General Cleaning

11

· Troubleshooting

11

2 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Important Safety Information
All products manufactured and supplied by Bristan are safe to use provided that they are installed, operated and receive regular maintenance in accordance with these instructions. This product needs to be installed in accordance with, and meet the requirements of the Water Supply (Water Fittings) Regulations 1999 and current by-laws. For full Installation Requirements & Notes (IRN) please visit www.wrasapprovals.co.uk/approvals- directory
This product must not be modified in any way as this will invalidate the guarantee. Full access must be made available for future maintenance/servicing purposes. Before drilling into walls, check that there are no hidden electrical wires, cables or water supply pipes. This can be checked with the aid of an electronic detector. If power tools are used do not forget to:
– Wear eye protection – Unplug equipment after use If in doubt, contact a registered plumber or your Local Water Authority or the Secretary of the Institute of Plumbing, address as follows:The Institute of Plumbing, 64 Station Lane, Hornchurch, Essex, RM12 6NB, Tel: 01708 472791
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 3

Prior to Installation
The installation images are for illustrative purposes only, and your product may slightly differ in installation, depending on specification. Please refer to your specific shower kit contents page for specification information. These kits are designed to be used in conjunction with Bristan showers. We cannot guarantee compatability or adequate performance when used with other showers. Please refer to the installation manual supplied with your Bristan shower kits for their specification information. Your kit could also have adjustability at the wall arm as a telescopic riser, or come with an in-line diverter kit. This shower kit must be installed in compliance with current water regulations. If you have any doubts about the water regulation requirements contact your local water services provider or use the services of a professional plumber.
Crucial Dimensions
Loosely assemble the riser, making sure it can reach the connection point
on your fitting and the bracket will stay flush to the wall.
Plan your installation to accommodate for the tallest user, and measure the crucial dimensions for your installation. Use the diagram to take notes.
4 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Installation – Inline Diverter

1
Compression nut

Olive

2 Fit the rigid riser to the diverter valve. Tighten the compression nut fully using a suitable spanner to ensure a watertight seal. Connect your chosen hose and handset.

IMPORTANT Check for a label on the diverter. It must be pointing upwards to ensure correct operation.

Check your rigid riser kit bracket type to move to the next stage
of installation.
Compression Nut

Push the short connecting tube into the top outlet on the shower valve (not supplied). If your outlet connection is 15mm, please use the adaptor supplied before attaching the riser tube. Ensure the nut and olive are fitted to the connecting tube. Tighten the compression nut fully using a suitable spanner.

Olive NRV

Important: If using this product on a low pressure system (0.2 – 0.5bar) we recommend the NRV in the diverter to be removed to ensure maximum flow.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 5

Installation – Rigid Risers

1

2a

Where necessary, assemble the riser rail using the fixings supplied. Slide any adjustable fittings, nuts and brackets on to the rail if supplied.

2b

3

Fit the rigid riser to the top outlet. If attaching directly to a threaded connection, use the threaded adaptor where supplied. Ensure the olive is fitted and tighten the compression nut fully.
Adaptor for Threaded Connection
IMPORTANT Do not over tighten fixings. Wrap pipes in cloth when tightening to prevent damage to the finish.

Your riser rail could also be attached via grub screws. Check around the back or sides for grub screw placement.

Attach the wall arm using the fixings supplied.
Ensuring the riser is straight, adjust the bracket position if applicable and mark the position of the bracket(s) on to the wall.

6 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Installation – Rigid Risers
4

Disassemble the

bracket to reveal the

fixings/fixing holes.

Align in the marked

area on the wall

and mark up the

REMEMBER

fixing holes.

Check for

hidden pipes and

5

cables before drilling!

Drill the fixings holes and secure the bracket/
bracket fixings to the
wall using the fixings supplied.

6

Re-locate riser rail back on to the bracket/bracket fixings. Secure in place.
Re-attach the wall arm if necessary.
Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 7

Installation – Rigid Risers
7
Attach the fixed head, handset (if supplied) and hose (if supplied) to the shower.
Ensure the sealing washers are in place if supplied. Turn on the water supply and check
all joints and connections for any leaks.
8 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

Installation – Telescopic Round Risers

1

2

Slide the bracket, slider and nut on to the riser rail.

4

Tighten nut to secure riser.

To adjust the height unscrew the nut and move the pole to the desired height. Tighten nut again to secure in place.

6

REMEMBER

7

hicdadbCedlhnerieslplcinbikpgeeff!oosrraend

Attach the riser rail to the shower
and secure with the
nut.

3
Push the shower arm
into the riser rail.

5

Using a spirit level to ensure

the riser is

positioned

correctly, use

the assembled

riser to mark

the desired

position of the

bracket.

8

Disassemble bracket, align on the wall in
the correct position and mark location of holes to be drilled. Secure the bracket to the wall.

Secure the riser bracket and riser rail.

Attach the fixed head. To adjust height of head, see Step 4.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 9

Installation – Telescopic Square Risers

1

2

3 Attach the
riser rail to

the shower.

Check for grub screw(s) placement and secure in place.

Insert the shower arm into the riser rail.

Slide the bracket and slider on to the riser rail.

4

5 Tighten the grub screws at the back of the

bracket to secure the

shower arm.

To adjust the height of the shower arm, slightly loosen the grub screws and lift the lever on the bracket. Move the arm to the desired height, lower the lever, then tighten again to secure in place.

6

7

8

Using a spirit level to ensure
the riser is positioned correctly, use the assembled riser to mark the desired position of the bracket.

Drill holes. Secure the bracket to the wall.

Secure the riser bracket and riser rail.

Attach the fixed head. To adjust height of the shower head, see Step 4.

10 Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors.

General Cleaning
Bristan products are made from premium materials, with hand polished, PVD, EPD or electroplated finishes.
Your product should be regularly cleaned with warm water, a mild pH-neutral liquid soap, and polished with a soft cloth. Any residues from soap, toothpaste, shampoos and shower gels can cause blemishes if not rinsed off straight after use.
Household bleaches and cleaners contain harsh chemicals and may damage the surface finish. Avoid using abrasive cloths, scouring pads, scrub sponges, steel wool or anything similar.
Some surfaces such as nickel and pewter may be affected by the dye found in some cloths, so it is also important to avoid hanging cloths on surfaces.

Your Bristan shower head may have rub-clean nozzles for easy cleaning. Simply rub your fingers across the rubber spray jets regularly before you turn the shower
on to remove any scale or debris.

Troubleshooting

Symptom

Cause(s)

Remedy

Partially closed isolation valve.

Open isolation valve.

Head of water is below the minimum distance required.

Refer to your specific product’s Contents Page for the minimum working pressure/distance required.

Inlet filter in the shower valve is blocked

Refer to the shower fitting instructions for Maintenance steps.

Hot or cold water being drawn off

No flow or elsewhere causing pressure changes

low flow or instantaneous boiler temperature

rate

changes.

Do not use other water outlets when using the taps.

Airlock or partial blockage in the supply Flush through pipework to ensure

pipework or hoses.

removal of debris and any airlocks.

Shower hose is kinked, causing a blockage.

Un-kink the shower hose and check for any damage, Replace if necessary.

Water supply failure

Investigate water supply. Check your plumbing and heating systems for any faults.

Water dripping from shower kit

This is normal for a short time after using the shower.

This is caused by residual water tension, the build up of water in the tap body.

If water continues to drip,

Refer to the Maintenance section of

possibly due to the ceramic disc valves/ your shower instructions to replace the

cartridge

valves/cartridge.

Need help? Give us a call on 0330 026 6273 and speak to one of our trained advisors. 11

Issue: D1 Part Number: FI Fix-Tel Kits

Bristan Group Ltd.

UK: Bristan Group, B78 1SG. EU: Masco Europe S.à.r.l.
14 Rue Strachen 6933 Mensdorf Luxembourg

Customer Service: +44330 026 6273

Web:

www.bristan.com

Email:

enquire@bristan.com

A Masco Company

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees on all our products, effective from the date of purchase, to give you peace of mind. To start your free guarantee simply scan the QR code and register your product. Alternatively visit www.bristan.com/register. For any other queries, please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice. For full guarantee terms and conditions visit www.bristan.com/service-centre/guarantees.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRISTAN User Manuals

Related Manuals