WOODBRIDGE B0970S Smart Bidet Toilet Instruction Manual
- June 2, 2024
- WOODBRIDGE
Table of Contents
- WOODBRIDGE B0970S Smart Bidet Toilet
- IMPORTANT SAFEGUARDS
- WOODBRIDGE
- LIST OF MATERIALS
- DIMENSION/TECHNICAL DATA
- PARTS IDENTIFICATION
- INSTALLATION OF CERAMIC TOILET
- PREVIOUS PREPARATEION
- DAILY MAINTENANCE
- EMERGENCY TROUBLESHOOTING
- THE ILLUSTRATION OF MAIN UNIT KEYS
- TROUBLESHOOTING GUIDE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WOODBRIDGE B0970S Smart Bidet Toilet
- Thank you for choosing our products. Please read the instructions carefully before installation and keep it available for future maintenance or reference.
- Our company reserves the right to the final interpretation of this manual.
- The manual is subject to change without notice.
IMPORTANT SAFEGUARDS
When using electrical products, especially when children are present, basic safety precautions should always be followed, including the following:
- The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction.
- Children are being supervised not to play with the appliance.
- This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
- Children shall not play with the appliance.
- Cleaning and user maintenance shall not be made by children without supervision.
READ ALL INSTRUCTIONS BEFORE USING
DANGER – To reduce the risk of electrocution:
- Do not use it while bathing.
- Do not place or store products where it can fall or be pulled into a tub or sink.
- Do not place in or drop into water or other liquid.
- Do not reach for a product that has fallen into the water. Unplug immediately.
- Do not wash the main unit or electrical plug with water or detergent.
- Do not handle the electrical plug with wet hands.
- Do not put a hand or other staff over the outlet of air dryer or block the outlet of air dryer.
- Never disassemble, repair or modify this product.
- During installation, disassembly, repair and maintenance of the product,the power plug must be switched off and water supply be shut off.
WARNING– To reduce the risk of burns, electrocution, fire, or injury to persons.
- Close supervision is necessary when this product is used by, on, or near children or invalids.
- Use this product only for its intended use as described in this manual. Do not use attachments not recommended by the manufacturer.
- Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or dropped into water. Return the product to a service center for examination and repair.
- Keep the cord away from heated surfaces.
- Never use while sleeping or drowsy.
- Never drop or insert any object into any opening or hose.
- Do not use outdoors or operate where aerosol (spray) products are being used or where oxygen is being administered.
- Connect this product to a properly grounded outlet only. See Grounding Instructions.
- Do not throw cigarettes and other burning stuff into the toilet, otherwise, it might cause fire.
- This product is an electric appliance, so it must be placed far away from water. Please don’t drench urine and other liquid to it.
- Do not lay on side or upside the product during the electrical circuit.
- It is prohibited to use other electric appliances in the same socket.
- It is forbidden to use the power extension or unstable loose outlet.
- The old aging water supply hose can not be used, otherwise, it might cause leakage, fire or electrical shock. Installation of the bidet seat should include specified components and new water supply hose.
CAUTION
Indicates that failure to follow the instruction may cause body injury or
property damage.
- Do not install or use the product in wet places as steam rooms etc. This product must be connected to a properly grounded power outlet socket.
- It is recommended to use a water-proof electrical outlet which should be installed in a place where is not easily got wet.
- This product should be used with AC 110V-120V,50/60Hz electrical current only,load current is at least 15A. P ower plug must be equipped with a ground fault circuit interrupter or ground fault electrical leakage protector or similar high sensitive, rapid type leakage switch (Rated sensitive current under 6mA).
- When it thunders,it is strongly recommended to pull out the power plug.
- Do not stand on ceramic toilet.
- Ceramic toilet must install floor fixing bolt.
- Do not stand on the product unit,seat and cover.
- Do not lean against the seat cover when using the product,to avoid damage.
- This product is equipped with a soft-closing seal cover.Heavy pressing or pushing may damage the soft-closing damper.
- Do not use lacquer thinner, petrol,liquid medicine, detergent, insecticide,toilet cleanser and scrubbing brush to clean the product.
- Exposure to direct sunlight is prohibited.
- Only use tap water or potable water; otherwise, it may cause chafing.
- Do not connect water supply to heater outlet.Make sure inlet water temperature at 3~35˚C
- When the room temperature is under zero degrees,please dry up the water tank,to avoid freezing.
- Raise rest room temperature to prevent the toilet from being damage due to freezing.
- When move the product from cold or wet environment into normal room temperature,wait for 2 hours until the condensation water is fully volatilized.Doing so can prevent the product from electrical short-circuit.
- When not using the product over three(3) days,drain the water out of the container and pull the electrical plug from the wall outlet.
- Stop using the product and shut off the power when product malfunctions,please contact the service people for professional service.
GROUNDING INSTRUCTIONS
This product should be grounded. In the event of an electrical short circuit,
grounding reduces the risk of electric shock by providing an escape wire for
the electric current. This product is equipped with a cord having a grounding
wire with a grounding plug. The plug must be plugged into an outlet that is
properly installed and grounded.If repair or replacement of the cord or plug
is necessary, do not connect the grounding wire to either flat blade terminal.
The wire with insulation having an outer surface that is green with or without
yellow stripes is the grounding wire.
This product is factory equipped with a specific electric cord and plug to permit connection to a proper electric circuit. Make sure that the product is connected to an outlet having the same configuration as the plug. No adapter should be used with this product. Do not modify the plug provided — if it will not fit the outlet, have the proper outlet installed by a qualified electrician. If the product must be reconnected for use on a different type of electric circuit, the reconnection should be made by qualified service personnel.
WOODBRIDGE
Model | B0970S |
---|
Main Unit
| Rating pressure| 110V-120V,50/60Hz
Rating power| 1200W-1400W
Overall unit
Waterproof
| IPX4
Electrical wire| length is about 1.5m
Toilet
| Flush volume| 4.8L(full flush6.0L/half flush4.2L)
Flushing mode| Siphonic jet
Rough-in distance| 12″| 15 3/4″
Outlet outside
diameter
| 3 1/2″
Drainage method| Down-drain
Water pressure range| 0.09MPa (dynamic water pressure, flow rate 15.0L/min or
more)–0.8MPa (static water pressure)
Cleaning device
| Heating mode| Instant heated
Heating power| 1400W
Water temperature| 6 different level adjustment
Water volume| 3 different level adjustment
Cleansing mode
| ****
Rear washing/Massage washing , Feminine washing/ Massage washing,
Spray cleansing location| 5 different level adjustment
Water pressure
protector
| Pressure stabilizer,Automatic pressure discharging
Anti-fouling device| Automatic cleansing nozzle, Anti-syphon device, Anti-
backflow device, Filter device
Safety device
| Thermal fuse, Water temperature senor, Ground protection,
Thermostat,
Over temperature protection , Leakage protection plug
Drying device
| Warm air volume| Over 0.2m3/min
Warm wind
temperature
| 6 different level adjustment
Heating power| 250W
Safety device| Thermal fuse, Temperature senor, Thermostat
Model| B0970S
---|---
Deodorization| Deodorization Method| Diatoms Deodorization
Heated seat
| Surface temperature| 6 different level adjustment
Heating power| 50W
Open and close
device
| Quiet soft-closing device,Auto open and close
Heated burning
protection
| The seat temperature will automatically lower to level 1 in 10 minutes after
using
Safety device| Sensed area,Temperature senor,Thermal fuse, Bimetal
thermostat,Leakage protection plug
Caring device
| Night light
assembly
| Intelligent,often in the off state
User ID setting| To avoid disturbance from remote controls by multi-user
Automatic flushing
| Toilet will automatically flush as user walks away from bowl
Antibacterial position| Seat, Spray nozzle
LIST OF MATERIALS
DIMENSION/TECHNICAL DATA
The product drawing is for reference only, and we reserve the right to modify the appearance of the product.
The product drawing is for reference only, and we reserve the right to modify the appearance of the product.
PARTS IDENTIFICATION
INSTALLATION OF CERAMIC TOILET
Precaution before installing
Minimum dynamic working water pressure: 0.09MPa or more (15.0L/min or more),
failure to meet this pressure will not achieve the best flushing effect.
Remark: Apply the methods below if you don’t have water pressure testing
device.
- Installation of mating angle valve Draw drain outlet centerline on the floor, Install angle valve at proper position on wall according to dimension of toilet.
- Cardboard installation
- Align cardboard with the centerline of drain outlet;
- Draw contour line according to cardboard;
- Hose
- Connect the water inlet and angle valve of the toilet with the matching hose and tighten it
- Ceramic toilet installtion
- Install sealing flange into drain outlet;
- Install ceramic toilet on corresponding position according to contour line.
- Tips:The toilet is heavy, and it needs to open the seat cover to carry it by two people.
- Silicone caulking application Apply high quality mildew glass glue around the lower edge of the toilet.
PREVIOUS PREPARATEION
-
Turn on the angle valve Check thread connection, make sure no leakage is found,unscrew angle valve anticlockwise to maximum opening.
(Tips: When opening for the first time, the angle valve handle has a larger torque) -
Power Connection Insert power line leakage protection plug into the power socket, press the reset switch, plug indicator lights on indicating that the power is on.
-
Press electric leakage test button prior to usage, the reset switch pops up indicating that the leakage protection function is normal. Press the TEST button (then RESET button) every month to assure proper operation.
-
Self-inspection
-
The main unit buzzer rings “beep”, first blue light on, then blue light off; red light up again, start self-inspection.
-
The main unit buzzer rings another “beep”, self-inspection finish, blue light off.
-
Start function mode for normal usage.
DAILY MAINTENANCE
Main unit care and maintenace
- Shut off power supply at maintenance.
- Wipe the stain with a soft damp cloth.
- Safety self- inspection After cleaning, re-connect the toilet with the power supply.
Spray nozzle maintenance and care
- Nozzle self-cleaning
When no user is seated, press the “rear cleaning button” on the main unit to start nozzle self-cleaning manually, the nozzle will automatically moves forward and clean itself with water.
- Spray nozzle disassemble
When the nozzle moves forward,the nozzle can be disassembled to clean.
-
Use soft cloth or soft brush to clean Do not pull or push the spray rod,to avoid damage.
-
Nozzle retraction Put the nozzle back to the front of the boom and press the “Stop” button to automatically retract the nozzle.
EMERGENCY TROUBLESHOOTING
Maintenance of filter net Time for maintenance: It is under normal water pressure but poor flush performance occurs.
-
Turn off power and the angle valve
-
Unscrew angle valve nut
-
Remove filter net
-
Use the brush to clean filter net
-
Reinstall filter and angle valve nut, turn on the angle valve and connect power,then it can work normally after self inspection.
-
No water supply
-
Put around 8L water into a barrel and flush the bowl of ceramic.
Note: Avoid water spilling from bowl. -
Failure of remote control Operate through the toilet body knob
When the product is left unused for long time Especially in winter when no one at home for a long time, please drain out the water inside tank and pipe to prevent freezing.
- Drain out the water inside tank Activate flushing, and then turn off angle valve to prevent water inlet.
- Drain out the water inside pipe Unscrew the hose connector off angle valve, drain the water in the pipe and reinstall.
- Unplug and cut off the electricity
- Handle the remaining water in bowl It is suggested to put some
THE ILLUSTRATION OF MAIN UNIT KEYS
Tips
When the main unit is initializing, the “stop” button lights up, after about
1.5s, the blue light (ECO light) will switch to red light (power light) .
Under ECO mode, the “stop” button lights up blue light (ECO light). Under
working mode, the “stop” button lights up red light (power light). Under
power-off mode, the “stop” button on the main unit lights off. Right after
main unit starts up, all function levels default to middle level. If the
remote control is used, all function levels will switch to the levels set by
the remote control.
TROUBLESHOOTING GUIDE
Problem | Cause | Solution |
---|
No Water from Nozzle
| Water inlet hose bent to cause blocking| Solve the problem of bending of
water inlet hose
Inlet valve is off| Turn on the inlet valve
Water supply is cut off| Connect water supply and wait for the water
Weak water cleaning
| Water inlet hose bent to
cause partial blocking
| Solve the problem of bending
of water inlet hose
Inlet valve is not fully turned on| Turn on the inlet valve fully
Inlet filter blocked| Clean the filter
Low water
temperature
| The water temperature is setted on normal temperature level| Reset the water
temperature
Low seat temperature| The seat temperature is setted on normal temperature
level| Reset the seat temperature
In standby mode| Switch to functional mode and use it after 3 minutes of use
Low wind temperature| The wind temperature is setted on normal temperature
level| Reset the wind temperature
No wind out| In standby mode or power save mode| Shift to function mode to use
dry function
Spray wand cannot retracted
| Power off| Push back the rod lightly and wait for the power
Get stuck by impurities| Clear away the impurities
Spray wand cannot stretch out
| Power off| Push back the wand lightly and wait for the power
Not sit in sensing area| Sit right in the sensing area
Remote control cannot display| The battery of the remote control
is installed in the opposite direction
| Reload the battery
Malfunction of deodorization
| User doesn’t reach the sensing area in seat| Adjust to reach the sensing
area
Deodorization function keeps working after user leaves| It’s a normal
phenomenon if deodorization function keeps working after user leaves to ensure
eliminating smell entirely
Caution
| If the problems cannot be solved as per above methods, please shut-off the
power, and contact service providers for maintenance.
If the leakage circuit breacker often trips off, it means the products has
electricity leakage, so please shut-off the
power, and contact service provider for maintenance.
Customer Service Phone: 562-229-0088. (Monday – Friday 9 AM – 5 PM Pacific Time) Or Email: help@woodbridgebath.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>