GYS PROTIG 161 D Tig Welding Machine User Manual
- June 3, 2024
- GYS
Table of Contents
PROTIG 161 D Tig Welding Machine
User Manual
PROTIG 161 DC
PROTIG 161 D Tig Welding Machine
WARNING – SAFETY RULES
GENERAL INSTRUCTIONS
Read and understand the following safety recommendations before using or
servicing the unit. Any change or servicing that is not specified in the
instruction manual must not be undertaken.
The manufacturer is not liable for any injury or damage due to non-compliance
with the instructions featured in this manual. In the event of problems or
uncertainty, please consult a qualified person to handle the inspection
properly.
ENVIRONMENT
This equipment must only be used for welding operations in accordance with the
limits indicated on the descriptive panel and/or in the user manual. The
operator must respect the safety precautions that apply to this type of
welding. In case of inadequate or unsafe use, the manufacturer cannot be held
liable for damage or injury.
This equipment must be used and stored in a place protected from dust, acid,
or any other corrosive agent. Operate the machine in an open, or well-
ventilated area.
Operating temperature:
Use between -10 and +40°C (+14 and +104°F).
Store between -20 and +55°C (-4 and 131°F).
Air humidity:
Lower or equal to 50% at 40°C (104°F).
Lower or equal to 90% at 20°C (68°F).
Altitude:
Up to 1000 meters above sea level (3280 feet).
PROTECTION OF THE INDIVIDUALS
Arc welding can be dangerous and can cause serious and even fatal injuries.
Welding exposes the user to dangerous heat, arc rays, electromagnetic fields,
noise, gas fumes, and electrical shocks. People wearing pacemakers are advised
to consult with their doctor before using this device.
To protect oneself as well as others, ensure the following safety precautions
are taken:
In order to protect yourself from burns and radiation, wear clothing without cuffs. These clothes must be insulated, dry, fireproof, and in good condition, and cover the whole body.
Wear protective gloves which guarantee electrical and thermal insulation.
Use sufficient welding protective gear for the whole body: hood, gloves,
jacket, trousers… (varies depending on the application/operation). Protect the
eyes during cleaning operations. Do not operate whilst wearing contact lenses.
It may be necessary to install fireproof welding curtains to protect the area
against arc rays, weld spatters, and sparks.
Inform the people around the working area to never look at the arc or the
molten metal, and to wear protective clothing.
Ensure ear protection is worn by the operator if the work exceeds the authorized noise limit (the same applies to any person in the welding area).
Stay away from moving parts (e.g. engine, fan…) with hands, hair, clothes,
etc…
Never remove the safety covers from the cooling unit when the machine is
plugged in – The manufacturer is not responsible for any accident or injury
that happens as a result of not following these safety precautions.
The pieces that have just been welded are hot and may cause burns when
manipulated. During maintenance work on the torch or the electrode holder, you
should make sure it’s cold enough and wait at least 10 minutes before any
intervention. The cooling unit must be on when using a water-cooled torch in
order to ensure that the liquid does not cause any burns.
ALWAYS ensure the working area is left as safe and secure as possible to
prevent damage or accidents.
WELDING FUMES AND GAS
The fumes, gases, and dust produced during welding are hazardous. It is
mandatory to ensure adequate ventilation and/or extraction to keep fumes and
gases away from the work area. An air-fed helmet is recommended in cases of
insufficient air supply in the workplace.
Check that the air intake is in compliance with safety standards
Care must be taken when welding in small areas, and the operator will need supervision from a safe distance. Welding certain pieces of metal containing lead, cadmium, zinc, mercury, or beryllium can be extremely toxic. The user will also need to decrease the
workpiece before welding.
Gas cylinders must be stored in an open or ventilated area. The cylinders must
be in a vertical position secured to support or trolley.
Do not weld in areas where grease or paint is stored.
FIRE AND EXPLOSIONS RISKS
Protect the entire welding area. Compressed gas containers and other
inflammable material must be moved to a minimum safe distance of 11 meters.
A fire extinguisher must be readily available.
Be careful of spatter and sparks, even through cracks. It can be the source of
a fire or an explosion.
Keep people, flammable objects, and containers under pressure at a safe
distance.
Welding of sealed containers or closed pipes should not be undertaken, and if
opened, the operator must remove any inflammable or explosive materials (oil,
petrol, gas…).
Grinding operations should not be directed towards the device itself, the
power supply, or any flammable materials.
GAS BOTTLE
Gas leaking from the cylinder can lead to suffocation if present in high
concentrations around the work area.
Transport must be done safely: Cylinders closed and product off. Always keep
cylinders in an upright position securely chained to a fixed support or
trolley.
Close the bottle after any welding operation. Be wary of temperature changes
or exposure to sunlight.
Cylinders should be located away from areas where they may be struck or
subjected to physical damage.
Always keep gas bottles at a safe distance from arc welding or cutting
operations, and any source of heat, sparks or flames.
Be careful when opening the valve on the gas bottle, it is necessary to remove
the tip of the valve and make sure the gas meets your welding requirements.
ELECTRIC SAFETY
The machine must be connected to an earthed electrical supply. Use the
recommended fuse size.
An electrical discharge can directly or indirectly cause serious or deadly
accidents.
Do not touch any live part of the machine (inside or outside) when it is
plugged in (Torches, earth cable, cables, electrodes) because they are
connected to the welding circuit.
Before opening the device, it is imperative to disconnect it from the mains
and wait 2 minutes, so that all the capacitors are discharged.
Do not touch the torch or electrode holder and earth clamp at the same time.
Damaged cables and torches must be changed by a qualified and skilled
professional. Make sure that the cable cross section is adequate with the
usage (extensions and welding cables). Always wear dry clothes in good
condition, in order to be insulated from the electrical circuit. Wear
insulating shoes, regardless of the environment in which you work in.
EMC CLASSIFICATION
These Class A devices are not intended to be used on a residential site where the electric current is supplied by the public network, with a low-voltage power supply. There may be potential difficulties in ensuring electromagnetic compatibility on these sites, because of the interferences, as well as radio frequencies.
This equipment does not comply with IEC 61000-3-12 and is intended to be connected to private low-voltage systems interfacing with the public supply only at the medium- or high-voltage level. On a public low-voltage power grid, it is the responsibility of the installer or user of the device to ensure, by checking with the operator of the distribution network, which device can be connected.
Provided that the impedance of the low-voltage public electrical network at
the common coupling point is less than Zmax = 0.409 Ohms, this equipment
complies with IEC 61000-3-11 and can be connected to public low-voltage
electrical mains.
It is the responsibility of the installer or user of the equipment to ensure,
in consultation with the distribution network operator if necessary, that the
network impedance complies with the impedance restrictions.
ELECTROMAGNETIC INTERFERENCES
The electric currents flowing through a conductor cause electrical and magnetic fields (EMF). The welding current generates an EMF field around the welding circuit and the welding equipment.
The EMF fields may disrupt some medical implants, such as pacemakers. Protection measures should be taken for people wearing medical implants. For example, access restrictions for passers-by or an individual risk evaluation for the welders.
All welders should take the following precautions in order to minimize exposure to the electromagnetic fields (EMF) generated by the welding circuit::
- position the welding cables together – if possible, attach them;
- keep your head and torso as far as possible from the welding circuit;
- never enroll the cables around your body;
- never position your body between the welding cables. Hold both welding cables on the same side of your body;
- connect the earth clamp as close as possible to the area being welded;
- do not work too close to, do not lean, and do not sit on the welding machine
- do not weld when you’re carrying the welding machine or its wire feeder.
People wearing pacemakers are advised to consult their doctor before using
this device.
Exposure to electromagnetic fields while welding may have other health effects
which are not yet known.
RECOMMENDATIONS TO ASSES THE AREA AND WELDING INSTALLATION
Overview
The user is responsible for installing and using the arc welding equipment in
accordance with the manufacturer’s instructions. If electromagnetic
disturbances are detected, it is the responsibility of the user of the arc
welding equipment to resolve the situation with the manufacturer’s technical
assistance. In some cases, this remedial action may be as simple as earthing
the welding circuit.
In other cases, it may be necessary to construct an electromagnetic shield
around the welding power source and around the entire piece by fitting input
filters. In all cases, electromagnetic interferences must be reduced until
they are no longer bothersome.
Welding area assessment
Before installing the machine, the user must evaluate the possible
electromagnetic problems that may arise in the area where the installation is
planned.
In particular, it should consider the following:
a) the presence of other power cables (power supply cables, telephone cables,
command cables, etc…)above, below, and on the sides of the arc welding
machine.
b) television transmitters and receivers ;
c) computers and other hardware;
d) critical safety equipment such as industrial machine protections;
e) the health and safety of the people in the area such as people with
pacemakers or hearing aids;
f) calibration and measuring equipment
g) the isolation of the equipment from other machinery.
The user will have to make sure that the devices and equipment that are in the
same room are compatible with each other. This may require extra precautions;
h) make sure of the exact hour when the welding and/or other operations will
take place.
The surface of the area to be considered around the device depends on the
building’s structure and other activities that take place there. The area
taken into consideration can be larger than the limits determined by the
companies.
Welding area assessment
Besides the welding area, the assessment of the arc welding systems
installation itself can be used to identify and resolve cases of disturbances.
The assessment of emissions must include in situ measurements as specified in
Article 10 of CISPR 11. In situ measurements can also be used to confirm the
effectiveness of mitigation measures.
RECOMMENDATION ON METHODS OF ELECTROMAGNETIC EMISSIONS REDUCTION
a. National power grid: The arc welding machine must be connected to the
national power grid in accordance with the manufacturer’s recommendation. If
interferences occur, it may be necessary to take additional preventive
measures such as the filtering of the power supply network. Consideration
should be given to shielding the power supply cable in a metal conduit. It is
necessary to ensure the shielding’s electrical continuity along the cable’s
entire length. The shielding should be connected to the welding current’s
source to ensure good electrical contact between the conduct and the casing of
the welding current source.
b. Maintenance of the arc welding equipment: The arc welding machine
should be submitted to a routine maintenance check according to the
manufacturer’s recommendations. All accesses, service doors, and covers should
be closed and properly locked when the arc welding equipment is on. The arc
welding equipment must not be modified in any way, except for the changes and
settings outlined in the manufacturer’s instructions. The spark gap of the arc
start and arc stabilization devices must be adjusted and maintained according
to the manufacturer’s recommendations.
c. Welding cables: Cables must be as short as possible, close to each
other, and close to the ground, if not on the ground.
d. Electrical bonding: consideration shoud be given to bonding all metal
objects in the surrounding area. However, metal objects connected to the
workpiece increase the risk of electric shock if the operator touches both
these metal elements and the electrode.
It is necessary to insulate the operator from such metal objects.
e. Earthing of the welded part: When the part is not earthed – due to
electrical safety reasons or because of its size and its location (which is
the case with ship hulls or metallic building structures), the earthing of the
part can, in some cases but not systematically, reduce emissions It is
preferable to avoid the earthing of parts that could increase the risk of
injury to the users or damage other electrical equipment. If necessary, it is
appropriate that the earthing of the part is done directly, but in some
countries that do not allow such a direct connection, it is appropriate that
the connection is made with a capacitor selected according to national
regulations.
f. Protection and plating: The selective protection and plating of other
cables and devices in the area can reduce perturbation issues. The protection
of the entire welding area can be considered for specific situations.
TRANSPORT AND TRANSIT OF THE WELDING MACHINE
Do not use cables or torches to move the machine. The welding equipment must
be moved in an upright position.
Do not place/carry the unit over people or objects.
Never lift the machine while there is a gas cylinder on the support shelf. A
clear path is available when moving the item.
The removal of the wire reel from the machine is recommended before
undertaking any lifting operation.
EQUIPMENT INSTALLATION
- Put the machine on the floor (maximum incline of 10°.)
- Ensure the work area has sufficient ventilation for welding, and that there is easy access to the control panel.
- The machine must not be used in an area with conductive metal dust.
- The machine must be placed in a sheltered area away from rain or direct sunlight.
- The machine protection level is IP21, which means :
– Protection against access to dangerous parts from solid bodies of a ≥12.5mm diameter and,
– Protection against vertically falling drops.
The power cables, extensions, and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not incur any responsibility regarding damages to both objects and persons that result from an incorrect and/or dangerous use of the machine.
Stray welding currents/voltages may destroy earth conductors, damaged electrical equipment, or cause components to warm up which may cause a fire.
– All welding connections must be firmly secured, check regularly!
– Check that the metal piece fixation is strong and without any electrical problems!
– Attach or hang all the electrically conductive elements, such as the trolley in order to insulate them.
– Do not place any electrical equipment such as drills on top of the welding machine without insulating them!
– Always place welding torches or electrode holders on an insulated surface when they’re not in use!
MAINTENANCE / RECOMMENDATIONS
- Maintenance should only be carried out by a qualified person. Annual maintenance is recommended.
- Ensure the machine is unplugged from the mains, and wait for two minutes before carrying out maintenance work. DANGER High Voltage and Currents inside the machine.
- Remove the casing 2 or 3 times a year to remove any excess dust. Take this opportunity to have the electrical connections checked by a qualified person, with an insulated tool.
- Regularly check the condition of the power supply cable. If the power cable is damaged, it must be replaced by the manufacturer, its after-sales service, or an equally qualified person.
- Ensure the ventilation holes of the device are not blocked to allow adequate air circulation.
- Do not use this equipment to thaw pipes, charge batteries, or start any engine.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorized by the manufacturer should perform the installation of the cutting equipment. During setup, the operator must ensure that the machine is unplugged. Connecting generators in a series or a parallel circuit is forbidden. It is recommended to use the welding cables supplied with the unit in order to obtain the optimum product settings.
DESCRIPTION
Thank you for choosing this machine. To get the best use of your machine,
please read the following carefully :
The MULTIWELD range is semi-automatic MIG/MAG, MMA, and flux-cored wire
welding stations. They are manual settings machines, with the help of the
table printed on the product. They are recommended for welding steel,
stainless steel, and aluminum.
MACHINE SUPPLIED WITH
| MULTIWELL 160M
013612| MULTIWELL 200M
066595
---|---|---
| ✓| ✓
| ✓| ✓
| ✓| ✓
The accessories supplied with the MULTIWELD generator may only be used with this product.
POWER SUPPLY
The MULTIWELD is supplied with a 16A plug type CEE7/7 and must be connected to
a 230V single-phase power supply (50-60 Hz) with three earthed wires.
The absorbed effective current (I1eff) is displayed on the machine, for
optimal use. Check that the power supply and its protection (fuse and/or
circuit breaker) are compatible with the current needed by the machine. In
some countries, it may be necessary to change the plug to allow the use at
maximum settings.
While under intensive use (superior to the duty cycle) the thermal protection
can activate, in that case, the arc switches off and the thermal protection
indicator switches on.
CONNECTION ON A GENERATOR
The machine can work with generators as long as the auxiliary power matches
these requirements :
- The voltage must be AC, always set as specified, and the peak voltage below 400V,
- The frequency must be between 50 and 60 Hz.
It is imperative to check these requirements as several generators generate high voltage peaks that can damage these machines.
USE WITH EXTENSION CABLES
All extension cables must have an adequate size and section, relative to the
machine’s voltage.
Use an extension that complies with national safety regulations.
| Input Voltage| Section of extension cable
---|---|---
MULTIWELL 160M| 230 V – 1~| 1.5 mm2
MULTIWELL 200M| 230 V – 1~| 2.5 mm2
DEVICE PRESENTATION (FIG. I)
1- Reel support | 9- Gas connector |
---|---|
2- Back cable support | 10- On/off switch |
3- Digital displays | 11- Power supply cable |
4- Adjustment of welding settings | Bottle support (max 1 x 4m³ bottles) |
5- European standard torch connection | 13- Plug 36V AC for gas preheater |
6- Polarity reversal cable | 14- Storage area |
7- Earth clamp connector | 15- Switch MIG/ MMA |
8- Torch support |
INTERFACE PANEL (FIG. VI)
1- Overheat/Overcurrent indicator | 5- Welding arc dynamic adjustment |
---|---|
2- Voltage display | 6- Wire speed adjustment (MIG) / Current setting |
adjustment (MMA)
3- Current display| 7- Voltage setting adjustment
4- Green light «ON»|
SWITCHING ON
The ON/OFF switch is located at the back of the machine. Press the switch on the «I» position to start the generator. This switch must not be turned off (to «O») while welding. When the machine is powered, the ON LED lights up (FIG VI – 4).
SEMI-AUTOMATIC FOR STEEL/STAINLESS STEEL (MAG MODE)
Set the voltage output and the wire speed according to the thickness of the
weld piece, following the instructions/ recommendations printed on the front
of the machine (fig. VII).
The MULTIWELD 160M can weld Steel wire of 0.6/0.8 mm, and Stainless Steel of
0.8 mm.
The MULTIWELD 200M can weld Steel wire of 0.6/1.0 mm, and Stainless Steel of
0.8/1.0 mm.
The products are fitted to work with 0.8 mm steel wire (roller Ø 0.8/1.0). The
contact tube, the groove of the roller, and the sleeve of the torch are all
compatible with 0.8 mm wire. Should you wish to weld 0.6 wire, use a torch of
a maximum of 3 m long. The contact tip must be changed (fig. IV-D) as well as
the wire feeder’s roller (fig. IV-B) must be replaced by an optional reference
(042339) with a 0.6 diameter groove. In this case, the position is in such a
way as to observe 0.6.
For use with Steel, the gas recommendation is argon + CO2. (Ar+CO2). The
proportion of CO2 required will vary depending on the use. For Stainless
Steel, use the combination of 2% CO2. If welding using pure CO2 protection
gas, you should connect a gas preheater to the gas bottle (Guys reference
046511 for a 230 V version). You may also use a standard 36 V preheater module
that can be connected to the 36V power supply plug located nearby the
soldering wire reel behind the lateral door (fig. I-13). For other specific
gas requirements, please contact your gas distributor. The gas flow in steel
is between 8 and 12 liters/minute depending on the environment.
SEMI-AUTOMATIC WELDING FOR ALUMINIUM (MIG MODE)
Set the voltage output and the wire speed according to the thickness of the
weld piece, following the instructions/recommendations printed on the front of
the machine (fig. VII).
The MULTIWELD 160M/200M can be equipped to weld with aluminum wire Ø 0.8 and
1.0 mm.
For use with aluminum, the gas requirement is pure argon (Ar). For the
specific gas requirements please contact your distributor.
The gas flow in Aluminium is between 15 and 25 Litres/minute depending on the
environment, and the experience of the welder.
Below are the differences between welding with Steel and Aluminium :
-
Specific rollers are needed for welding with Aluminium.
-
Adjust the pressure of the drive rolls to prevent the wire from being crushed.
-
Use the capillary tube (designed to guide the wire between the wire feeder and the EURO connector) only when welding steel or stainless steel (fig. II).
-
Use a special Aluminium Torch with a Teflon sheath to reduce friction.
DO NOT cut the sheath close to the joint, it is used to guide the wire from the rollers. -
Contact Tube: Use a special aluminum contact tube specific to the diameter of the wire being used.
GASLESS WIRE WELDING
Set the voltage output and the wire speed according to the thickness of the
weld piece, following the instructions/recommendations printed on the front of
the machine (fig VII).
The MULTIWELD 160M/200M can weld gasless wire to 0.9 mm if the polarity is
reversed (fig. III) respecting a maximum pressure of 5Nm. For parameters of
use, please refer to the instructions indicated on page 81. Welding gasless
wire with a standard nozzle can lead to overheating and deterioration of the
torch. It is recommended to use a “No Gas” nozzle (ref. 041868), or remove
the genuine nozzle (fig. III).
MIG / MAG SETTINGS PANEL
CONNECTION AND RECOMMENDATIONS
- Connect the earth clamp on the positive (+) or negative (-) terminal depending on the wire type (in general on the -).
MODE SELECTION AND SETTINGS
Press the switch (FIG I – 15) to select the welding mode MIG/MAG.
1. Setting the welding voltage :
Adjust the welding voltage using the voltage setting knob depending on the
work to be carried out. The voltage setpoint is indicated on the left side
display.
2. Setting the wire speed :
Adjust the wire speed using the central knob depending on the work to be
carried out.
2. Inductance settings :
Adjust the inductance level using the inductance setting knob , a relative
value from MIN to MAX. The lower the inductance level, the harder and more
guiding the arc. The higher the inductance and the softer the arc with little
splatter.
Set the voltage output and the wire speed according to the thickness of the weld piece, following the instructions/ recommendations printed on the front of the machine (fig VII).
REEL AND TORCH ASSEMBLY (FIG. IV)
This product takes Ø 200/300 mm wire reel (ecological).
- Remove the contact tube and its support (fig. D), and the nozzle (fig. E) from the torch.
Fig A :
- Open the door of the machine.
- Place the reel on the drive pin (3) of the reel support.
- Adjust the reel brake (4) to avoid reel movement tangling the wire when the welding stops. Be careful not to tighten too much – the reel must rotate without straining the motor.
Fig B :
The drive rolls supplied have two grooves (0.8 V shape grooves and 0.9 grooves
with teeth) :
- For 0.8mm steel wire, use the 0.8 V shape groove.
- For colored wire, turn the drive roll over and use the 0.9 mm groove with teeth.
- For 0.8mm aluminum wire, remove and replace the roll with a model specifically designed for aluminum with a U-shaped groove (not included).
Fig C :
To select the adjustment of the drive rollers.
-
Loosen the drive roller knob (3) as far as possible and insert the wire, tighten the knob again slightly.
-
Start the motor by pressing the trigger of the torch.
-
Tighten the knob whilst pressing the trigger until the wire starts to move.
ATTENTION: When welding with Aluminium, use the minimum possible pressure to avoid crushing the wire. -
Leave about 5cm of wire out of the torch, then put the contact tube (fig. D), and the nozzle (fig. E) adapted to the wire to be used at the extremity.
GAS CONNECTION
- Connect the manometer (flowmeter) to the gas bottle if needed, then connect the gas hose to the gas connector. To avoid gas leaks, use collars supplied in the accessories box.
- Make sure the gas bottle is held in place respecting chain fastening cf. fig. V.
- Set the gas flow by adjusting the dial located on the pressure regulator.
NB: to help facilitate the adjustment of the gas flow, operate the drive rollers by pressing the trigger of the torch (ensure that the drive roller is completely loose so the wire is not fed through). Maximum gas pressure 0.5 MPa (5 bars). This procedure does not apply to the «Gasless» welding mode.
RECOMMENDED COMBINATIONS
| (mm)| Current (A)| 0 Wire (mm)| 0 Nozzle (mm)| Flow rate Limn
---|---|---|---|---|---
MIG| 0.8-2| 20-100| 0.8| 12| 10-12
2-4| 100-200| 1.0| 12-15| 12-15
4-8| 200-300| 1.0/1.2| 15-16| 15-18
8-15| 300-500| 1.2/1.6| 16| 18-25
MAG| 0.6-1.5| 15-80| 0.6| 12| 8-10
1.5-3| 80-150| 0.8| 12-15| 10-12
3-8| 150-300| 1.0/1.2| 15-16| 12-15
8-20| 300-500| 1.2/1.6| 16| 15-18
RISK OF INJURY DUE TO MOVING PARTS
The wire feeders contain moving parts that may catch hands, hair, clothes, or
tools which can lead to injuries! Take extra care.
- Do not lay a hand to swivel or move components or parts to the drive!
- Ensure that the housing covers or protective covers remain closed during operation!
- Do not wear gloves when feeding the wire through or changing the reel.
MMA SETTINGS PANEL
CONNECTIONS AND RECOMMENDATIONS
- Connect the cables, electrode holder, and earth clamp in the connectors,
- Respect the welding polarities and intensities indicated on the electrodes boxes,
- Remove the electrode from the electrode holder when the machine is not in use.
MODE SELECTION AND SETTING
Press the switch (FIG I – 15) to select the mode MMA.
Setting the welding current :
Adjust the welding current using the central knob depending on the work to be
carried out. The current setpoint is indicated on the central side display.
WELDING CURRENT SETTINGS
The following settings concern the current range that may be used depending on
the electrode’s type and diameter. These ranges are quite large as they depend
on the application and the welding position.
160M | Øelectrode (mm) | Rutile E6013 (A) | Basic E7018 (A) |
---|---|---|---|
2. | 30-60 | 30-55 | |
2.0 | 50-70 | 50-80 | |
3. | 60-100 | 80-110 | |
3. | 80-150 | 90-140 | |
lAJOOZ | Ø electrode (mm) | Rutile E6013 (A) | Basic E7018 (A) |
--- | --- | --- | --- |
2. | 30-60 | 30-55 | |
2.0 | 50-70 | 50-80 | |
3. | 60-100 | 80-110 | |
3. | 80-150 | 90-140 | |
4.0 | 100-200 | 125-210 |
ELECTRODE WELDING
- The reverse polarity cable must be disconnected in MMA (stick welding) mode in order to connect the electrode holder and earth clamp. Connect the electrode holder and earth clamp as indicated on the electrode packaging.
- Respect the basic rules of welding.
- This device has 1 feature specific to Inverter machines :
– Anti-Sticking: Enables easy removal of the electrode from the metal. The anti-sticking feature, after its start, requires approximately a 3 seconds delay before resuming normal welding operations.
ADVICE & THERMAL PROTECTION
This device is equipped with a ventilator regulated by the inside temperature.
When the machine’s thermal protection is activated, it will not deliver any
current. Yellow light (fig. VI-1) will turn on until the temperature of the
machine has returned to normal.
-
Do not block/cover the ventilation holes, ensure free flow of air.
-
Whilst in thermal protection mode leave the machine plugged into the mains after welding to allow it to cool.
General observations : -
Always respect the basic rules of welding.
-
Always work in an adequately ventilated area.
-
Do not work on a damp surface.
-
In order to avoid gas leaks, use collar leak, use collars supplied in the accessories box.
– Make sure the gas bottle is held in place respecting chain fastening cf. fig. V.
– Set the gas flow by adjusting the dial located on the pressure regulator.
TROUBLESHOOTING
SYMPTOMS | POSSIBLE CAUSES | REMEDIES |
---|---|---|
The welding wire speed is not constant. | Debris is blocking up the opening. |
Clean out the contact batch or change it and replace the anti-adherence
product.
Ref. 041806.
The wire skids in the rollers.| • Control the roller pressure or replace it.
• Wire diameter non-compatible with a roller.
• Covering wire guide in the torch is non-compatible.
The wire-feeder motor doesn’t operate.| Reel or roller brake too tight.|
Release the brake and rollers.
Electrical supply problem.| Check that the power switch is in the «On»
position.
Bad wire feeding.| Covering wire guide dirty or damaged.| Clean or replace
The drive roller is too loose| Tighten the drive roller knob
The reel brake is too tight| Release the brake
No welding current| Bad connection to the main supply| Check the mains
connection and look if the plug is fed by 230 V (1PH) power socket.
Bad earth connection.| Check the earth cable (connection and clamp condition).
Torch trigger inoperative.| Check the torch trigger / replace the torch
The wire jams (after the rollers)| Guidewire sheath crushed.| Check the sheath
and torch body.
Wire jammed in the torch| Clean or replace.
No capillary tube.| Check the presence of the capillary tube.
Wire-speed too fast| Reduce the wire speed
The welding bead is porous| The gas flow rate is not sufficient.| Adjust flow
range 15 to 20 L / min.
Clean the working metal.
Gas bottle empty.| Replace it.
Gas quality unsatisfactory.| Replace it.
Airflow or wind influence.| Prevent drafts, and protect welding area.
The gas nozzle is dirty.| Clean or replace the gas nozzle.
Poor quality wire.| Use suitable WIRE for MIG-MAG welding.
Surface to weld in bad condition. (rust, etc…)| Clean the metal before
welding.
Very important flashing particles.| Arc voltage is too low or too high.| See
welding settings.
Bad earth connection.| Adjust the earth cable for a better connection.
Insufficient gas flow.| Adjust the gas flow.
No gas flow at the end of the torch.| Bad gas connection.| Check the gas
connection at the welding
machine. Check the gas regulator and the solenoid valves.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase
(parts and labor).
The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping off equipment, disassembling).
- Environment-related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
– The proof of purchase (receipt etc …)
– A description of the fault reported
I
II
A Steel | B Aluminium |
---|---|
MIG-MAG
MMA
Check the electrode polarity on the packaging.
III
IV
V
VI
VII
SPARE PARTS
| 160M| 200M
---|---|---
1| GAS Heating Socket| C21355
2| Fuse Holder| C13707
3| Wire Reel Support| 71503
4| Torch support| B31715
5| Handles| 56047
6| Wire feeder| 53530| C51563
7| Polarity inversion cable| 71918| 83158
8| Texas Connector| 1312
9| Display PCBA| 84024
10| Auxiliary Transformer| B2031
11| Front wheels| 71361
12| Rear Cable Support| B31717
13| Solenoid valve| 71540
14| Switch| 53546| C51524
15| Power Cable| 21468| C51155
16| Main circuit board| 53497| B4135
17| Fan| 51021| C16541
18| 200mm diameter wheels| 71357
CIRCUIT DIAGRAM
TECHNICAL SPECIFICATIONS
| 160M| 200M
---|---|---
Primary
Power supply voltage| 230 V +/- 15%
Mains frequency| 50 / 60 Hz
Fuse| 16 A
Maximum effective supply current IIeff| 12.5 A| 16 A
Maximum supply current Ilmax| 28 A| 41 A
Mains cable section| 3 x 1.5 min2| 3 x 2.5 rn2
Maximum active power consumed| 4.2 kW| 6.2 kW
Idle consumption| 22 W| 22 W
Eficiencia a 12max| 84%| 83%
Power factor at I2max (A)| 0.58| 0.62
EMC class| A
Secondary| MMA| I MIG-MAG| MMA| I MIG-MAG
No load voltage| 59 V| 65 V
Type of welding current I Tipo de corriente de soldadura| DC
Welding modes| MMA, MIG-MAG
Minimum welding current| 20 A| 30 A
Normal current output (I,)| + 140 A| 30 + 160 A| 30 + 180 A| 30 + 200 A
Conventional voltage output (U,)| + 25.6 V| 15.5 4 22 V| 21.2 + 27.2 V| 15.5
4 24 V
Irna<| 20%| 15%
100%| 70A| 75A| 80A| 90A
Duty cycle at 40°C (10 min)* Standard EN60974-1. 60%| 90 A| 95 A| 104 A| 115 A
|
Minimum and a maximum diameter of filler Acier / Steel| 0.6 4 0.8 mm| 0.6 4
1.0 mm
Diametro minimo Inox| 0.8 mm| 0.8 mm-21.0 mm
Minimale en maximale diameter van het lasdraad| 0.8 -21.0 min| 0.8 + 1.0 mm
Fil fourth / Cored| 0.9 mm| 0.9 mm
Torch connector| EURO
Drive roller type| A
Motor speed| 3 > 10 m/min| 2 > 13 m/min
Motor power| 40 W| 50 W
Maximum diameter of the supply reel| 0 300 mm
Maximum weight of the filler wire reel| 18 kg
Maximum gas pressure (Pmax)| 0.5 MPa (5 bar)
Functioning temperature| -10°C + +40°C
Storage temperature| -20°C + +55°C
Protection level| IP21
---|---
Minimum coil insulation class| B
Dimensions (LxWxH)| 77 x 79 x 47 cm
Weight| 34.2 kg| 34.5 kg
*The duty cycles are measured according to standard EN60974-1 à 40°C and on a 10 min cycle.
While under intense use (> to duty cycle) the thermal protection can turn on,
which switches the arc off and the indicator switches on.
Keep the machine’s supply on, to enable cooling until protection cancellation.
The machine has a specification with a “dropping current output” in MMA and
with a “constant current output” in MIG/MAG.
| – Caution! Read the user manual.
---|---
| – Inverter current technology-based source delivering direct current.
EN60974-1
EN60974-5
EN60974-10
Class A| – This welding machine is compliant with standard EN60974-1/-5/-10 of
doss A.
| MMA welding (Manual Metal Arc)
| – MIG / MAG-Schreiten
S| – Suitable for welding in an environment with an increased risk of
electric shock. Sudi a current source must not however be placed in the
warding room or in the surroundings.
IP21| Protected against rain and against fingers access to dangerous parts.
| Direct welding current.
U0| No-load voltage
X(40°C)| •Enschaltdauer: 10 Si – 40°C, nchtlinienkonform 91609741 – Ocb de
trabajo segan la norma EN60974-1 (10 minutos -40°C).
12| 12: corresponding conventional welding current
A| Amperes – Amperes – Ampere – Amperios – Asinepa – Ampere – Ampere – Margery
U 2| U2: Conventional voltage in corresponding loads
V| Volt
Hz| Hertz
| •Single phase power supply 50 or 60Hz.
U1| – Rated power supply voltage.
---|---
I1max| – Maximum-rated power supply current (effective value).
I1eff| – Maximum effective rated power supply current.
| – Device(s) compliant with European directness The certificate of compliance
is wadable on our website.
| – EAC Conformity marking (Eurasian Economic Community).
| Int rada de gas
| – This hardware is subject to the waste collection according to the European
correctives 2002/96/0E. Do not Throw it out in a domestic tin!
| – Produd0 recidable que requiere una separacian deterrninada.
| – Equipment in conformity with Moroccan standards. The dedarabon Cp (CMIM)
of conformity is available on our website (see cover page).
| – Equipment in compliance with &Kish requirements. The British Dedarabon of
Conformity is available on our website (see home page).
| – Temperature information (thermal protection).
GYS SAS
1, rue de la Croix des Landes
CS 54159
53941 SAINT-BERTHEVIN Cedex
France
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>