PTI-s7 400 V Welding Machine
User Manual
ASSEMBLY OF SUPPORT
CABLE SUPPORT ASSEMBLY
ASSEMBLY OF ARM SUPPORT
ASSEMBLY OF OVERHANGING ARM
|
---|---
To adjust the tension of the cable in the pulley system, the user must place the clamp on the cable.
GYSPOT PTI S7
|
---|---
WARNING – SAFETY RULES
GENERAL INSTRUCTIONS
Read and understand the following safety instructions before use. Any
modification or updates that are not specified in the instructions manual
should not be undertaken. Please store this manual safely.
The manufacturer is not liable for any injury or damage due to a non-
compliance with the instructions featured in this manual.
In the event of problems or uncertainties, please consult a qualified person
to handle the installation properly. The instructions cover the material in
the condition it was delivered. It is the responsibility of the user to
analyse the risks taken when not following the instructions published by GYS.
ENVIRONMENT
This equipment must only be used for welding operations in accordance with the
limits indicated on the descriptive panel and/or in the user manual.
Safety instructions must be followed. In case of improper or unsafe use, the
manufacturer cannot be held liable.
This equipment must be used and stored in a room free from dust, acid,
flammable gas or any other corrosive agent. Operate the machine in an open, or
well-ventilated area.
Operating temperature:
Use between -10 and +40°C (+14 and +104°F).
Storage between -20 and +55°C (-4 and 131°F).
Air humidity:
Lower or equal to 50% at 40°C (104°F).
Lower or equal to 90% at 20°C (68°F).
Altitude : Up to 1000 m above sea level (3280 feet).
INDIVIDUAL PROTECTION & OTHERS
Resistance welding can be dangerous and cause serious injuries or even
death. It needs to be used by a qualified technician with training relevant to
the machine.
Welding exposes the user to dangerous heat, arc rays, electromagnetic fields,
risk of electric shock, noise and gas fumes. People wearing pacemakers are
advised to consult a doctor before using the welding machine.
To protect oneself as well as others, ensure the following safety precautions
are taken:
In order to protect you from burns and radiations, wear clothing without turn-
up or cuffs. These clothes must be insulating, dry, fireproof, in good
condition and cover the whole body.
Wear protective gloves which guarantee electrical and thermal
insulation.
Use sufficient welding protective gear for the whole body: hood, gloves,
jacket, trousers… (varies depending on the application/ operation). Protect
the eyes during cleaning operations. Contact lenses are prohibited during use.
It may be necessary to install fireproof welding curtains to protect others
against arc rays, weld spatters and sparks. .
Ask people around the working area to look away from at the arc or the molten
metal, and to wear protective clothing.
Ensure ear protection is worn by the operator if the work exceeds the
authorised noise limit (the same applies to any person in the welding area).
Keep mobile parts at a distance (fan, electrodes…) from hands, hair and
clothing .
Never remove the safety covers from the cooling unit when the machine is
plugged in. The manufacturer is not liable for any injury
or damage caused due to non-compliance with the safety precautions.
Parts that have just been welded will be hot and may cause burns when
touched. During maintenance work on the torch or the electrode holder, you
should make sure it’s cold enough and wait at least 10 minutes before any
intervention. When using a watercooled torch, make sure that the cooling unit
is switched on to avoid any burns caused by the liquid. It is important to
secure the working area before leaving it to ensure protection of the goods
and the safety of people.
WELDING FUMES AND GASES
Fumes, gas and dust produced during welding are hazardous to health. It is
mandatory to ensure adequate ventilation and/ or extraction to keep fumes and
gas away from the work area. Using an air fed welding helmet is recommended in
case of insufficient ventilation in the workplace.
Check that the air supply is effective by referring to the recommended safety
regulations.
Precautions must be taken when welding in small areas, and the operator will
need supervision from a safe distance. Welding certain pieces of metal
containing lead, cadmium, zinc, mercury or beryllium can be extremely toxic.
The user will also need to degrease the workpiece before welding. Gas
cylinders must be stored in an open or ventilated area. They must be stored
vertically and held by a support or trolley to limit the risk of fall. Do not
weld in areas where grease or paint are stored.
- This welding equipment produces fumes and gases that contain chemicals considered by the State of California as a source of congenital malformations and potentially, cancers (refer to the California Health Code, chapter 25249.5 and after).
- This equipment contains chemicals, including lead, identified by the state if California as a potential cause of cancers and congenital malformations or other issues in relation to procreation. Wash your hands after handling.
FIRE AND EXPLOSION RISKS
Protect the entire welding area. Flammable materials must be moved to a
minimum safe distance of 11 meters. A fire extinguisher must be readily
available near the welding operations.
Be careful of weld spatter and sparks, even through cracks. If not careful
then this could potentially lead to a fire or an explosion.
Keep people, flammable materials/objects and containers that are under
pressure at a safe distance.
Welding in closed containers or pipes should be avoided and , if they are
opened, they must be emptied of any flammable or explosive material (oil,
fuel, gas …).
Grinding operations should not be carried out close to the power supply or any
flammable materials.
ELECTRICAL SAFETY
The electrical mains used must have an earth terminal. An electric shock could
cause serious injuries or potentially even deadly accidents.
Never make contact with live parts inside or outside the current source
(cables, electrodes, arms, guns…) as they are connected to the welding
circuit. Before opening the device, it is imperative to disconnect it from the
mains and wait 2 minutes, so that all the capacitors are discharged. Damaged
cables and torches must be changed by a qualified and skilled professional.
Make sure that the cable cross section is adequate with the usage (extensions
and welding cables). Always wear dry clothes which are in good condition in
order to be isolated from the welding circuit. Wear insulating shoes,
regardless of the workplace/environment in which you work in.
Warning! Very hot surface. Risk of burns.
• The parts and pieces that have just been heated are hot and may cause burns
when manipulated.
• Do not touch any hot parts with your hands.
• Wait for the parts and pieces to cool down before handling them.
• In case of burn, rinse thoroughly with water and consult a doctor as soon as
possible.
EMC MATERIAL CLASSIFICATION
This Class A machine is not intended to be used on a residential site where
the electric current is supplied by the domestic low-voltage power grid. There
may be issues in ensuring electromagnetic compatibility on these sort of
sites, due to conducted interferences as well as radiation.
This equipment does not comply with IEC 61000-3-12 and is intended to be
connected to private low-voltage systems interfacing with the public power
grid only at the medium- or high-voltage level.
If connected to a public low-voltage power grid, the installer or user of
the machine has to ensure, by checking with the network operator, that the
device can be connected.
ELECTROMAGNETIC INTERFERENCES
The electric current flowing through any conductor causes electrical and
magnetic fields (EMF). The welding current generates an EMF around the welding
circuit and the welding equipment.
The EMF electromagnetic fields can interfere with certain medical implants,
such as pacemakers. Protective measures must be taken for people having
medical implants. For example, by restricting access to passers-by or
conducting an individual risk evaluation for the welders.
All welders should take the following precautions in order to minimise
exposure to the electromagnetic fields (EMF) generated by the welding circuit:
- position the welding cables together – if possible, attach them;
- keep your head and upper body as far as possible from the welding circuit;
- never wrap the cables around your body;
- never position your body between the welding cables. Hold both welding cables on the same side of your body;
- connect the earth clamp as close as possible to the welding area;
- do not work too close to, do not lean and do not sit on the welding machine
- do not weld when transporting the welding machine or its wire feeder.
People wearing pacemakers are advised to consult their doctor before using
this device. Exposure to electromagnetic fields while welding may have other
health effects which are not yet identified.
RECOMMENDATIONS FOR WELDING AREA ASSESSMENT AND WELDING
Miscellaneous
The user is responsible for the correct installation and usage of the welding
material based on the instructions supplied by the manufacturer. If
electromagnetic disturbances are detected, it is the user’s responsibility to
resolve the situation with the manufacturer’s technical assistance. In some
cases, this corrective action may be as simple as earthing the welding
circuit. In other cases, it may be necessary to construct an electromagnetic
shield around the welding power source and around the entire piece by fitting
input filters. In all cases, electromagnetic interferences must be reduced
until they are no longer inconvenient.
Welding area assessment
Before installing the machine, the user must evaluate the possible
electromagnetic problems that may arise in the area where the installation is
planned. The following must be taken into account:
a) the presence (above, below and next to the arc welding machine) of other
power cables, remote cables and telephone cables;
b) television transmitters and receivers;
c) computers and other hardware;
d) critical safety equipment such as industrial machine protections;
e) the health and safety of people in the area especially if they are using
pacemakers or hearing aids;
f) calibration and measuring equipment;
g) the isolation of other pieces of equipment which are in the same area.
The operator has to ensure that the devices and equipment used in the same
area are compatible with each other. This may require extra precautions;
h) the time of day during the welding or other activities have to be
performed.
The dimension of the cutting area that has to be considered depends on the
size and shape of the building and the type of work undertaken. The area taken
into consideration might go beyond the limits of the installations.
Review of the welding installation
Reviewing the welding installations can be useful to determine and resolve any
case of electrical disturbances. The assessment of emissions must include in
situ measurements as specified in Article 10 of CISPR 11: 2009. In situ
measurements can also be used to confirm the effectiveness of mitigation
measures.
RECOMMENDAED METHODS TO REDUCE ELECTROMAGNETIC EMISSIONS
a. National power grid: The arc welding machine must be connected to the
national power grid in accordance with the manufacturer’s recommendation. In
case of interferences, it may be necessary to take additional precautions such
as the filtering of the power supply network. Consideration should be given to
shielding the power supply cable in a metal conduit or equivalent of
permanently installed arc welding equipment. It is necessary to ensure the
electrical continuity of the frame along its entire length. The shielding
should be connected to the welding current source to ensure a good electrical
contact between the conduit and the casing of the welding current source.
b. Maintenance of the resistance welding equipment: The resistance welding
machine should be subject to a routine maintenance check in line with the
recommendations of the manufacturer. All accesses, service doors and covers
should be closed and properly locked when the arc welding equipment is on. The
arc welding equipment must not be modified in any way, except for the changes
and settings covered in the instructions.
c. Welding cables: Cables must be as short as possible, close to each other
and close to the ground, if not on the ground.
d. Equipotential bonding: consideration should be given to bond all metal
objects in the surrounding area. However, metal objects connected to the
workpiece increase the risk of electric shock if the operator touches both
these metal elements and the electrode. It is necessary to insulate the
operator from such metal objects.
e. Earthing of the welded part: When the part is not earthed – due to
electrical safety reasons or because of its size or location (which is the
case with ship hulls or metallic building structures), the earthing of the
part can, in some cases but not systematically, reduce emissions It is
preferable to avoid the earthing of parts that could increase the risk of
injury to the users or damage other electrical equipment. If necessary, it is
appropriate that the earthing of the part is done directly, but the safety
rules in some countries may not allow such a direct connection and it is
appropriate that the connection is made using a capacitor selected according
to national regulations.
f. Protection and shielding: The selective protection and shielding of other
cables and devices in the area can reduce perturbation issues. The protection
of the entire welding area can be considered for specific situations.
TRANSPORT AND TRANSIT OF THE WELDING MACHINE
The top of the machine is equipped with handles for movement by hand. Be
careful not to underestimate the weight of the machine. The handles cannot be
used to lift the product.
Do not use the cables or torch to move the machine. Do not place/carry the
unit over people or objects.
EQUIPMENT INSTALLATION
- Put the machine on the floor (maximum incline of 10°).
- The machine must be placed in a sheltered area away from rain or direct sunlight.
- The machine protection level is IP20, which means :
- Protection against access to dangerous parts from solid bodies of a diameter ≥12.5mm and,
- Protection against water projections.
Power cables, extension leads and welding cables must be fully uncoiled to prevent overheating.
The manufacturer does not accept any liability in relation to damages caused
to objects or harm caused to persons as the result of incorrect and/or
dangerous use of the machine.
MAINTENANCE / RECOMMENDATIONS
- The operators must have received suitable training in order to use the machine at its maximum potential and weld correctly.
- Check which welding process is authorised by the manufacturer before attempting any vehicle repair.
The maintenance and repair of the machine can only be undertaken by the
manufacturer. Any work undertaken by a third party on the machine will
invalidate the warranty. The manufacturer will not accept liability in the
event of an incident that would occur after this work was undertaken.
Ensure the machine is unplugged from the mains, and then wait 2 minutes before
carrying out maintenance work. Inside the machine, voltage and current levels
are high and dangerous.
- Prior to any work on the machine, turn the air supply off and depressurise the circuit of the machine.
- Make sure to purge the filter of the dehumidifier located at the back of the machine regularly.
- The device is fitted with a balance system designed for easier handling. However, it is not recommended to leave the clamp hanging at the end of the cable of the balancing system for prolonged periods of time as it might increase wear. Do not drop the clamp repetitively or it might damage the balancing system.
- It is possible to adjust the tension of the balancing system spring using the spanner provided.
- The level of the cooling liquid is important for the machine to work correctly. It must always be between the «minimum» and «maximum» marks on the machine. Regularly check the level and top-up when needed.
- It is recommended to renew the cooling liquid every 2 years.
- All the welding tools will wear off with use. Ensure that these tools are clean to get the best results.
- Prior to using the pneumatic clamp, check the condition of the electrodes/caps (regardless if they are round or flat). If that is not the case, clean them using sand paper (thin grain) or replace them (see explanation on the machine).
- To ensure an efficient welding spot, it is necessary to replace the caps every 200 spots. In order to do so :
- Remove the caps using the caps removing wrench (ref. 050846)
- Fit the caps and apply contact grease (ref. 050440)
- Caps type A (ref : 049987)
- Caps type F (ref : 049970)
- Caps bevelled (ref : 049994)
Warning : the caps must be perfectly aligned. If this is not the case, check the alignment of the electrodes (cf. chapter «Assembly and replacement of the arms» P. 48)
-
Prior to using the gun, check the condition of the different tools (star, single sided electrode, carbon electrode…) and clean or replace if required.
-
Remove regularly the casing and any excess of dust. Take this opportunity to have the electrical connections checked by a qualified person, with an insulated tool.
-
Regularly review the condition of the power cable and welding connection cables. In case of visible signs of damage, organise for them to be replaced by the manufacturer or a qualified technician.
After each use make sure that the harness is not left twisted. A constantly twisted harness leads to its premature deterioration and can present an electrical hazard to the user. -
Ensure the vents of the device are not blocked to allow adequate air circulation.
INSTALLATION – PRODUCT OPERATION
Only qualified personnel authorised by the manufacturer should perform the
installation of the welding equipment. During the installation, the operator
must ensure that the machine is disconnected from the mains. Connecting
generators in serial or in parallel is forbidden.
EQUIPMENT DESCRIPTION (FIG-1)
This machine is designed to carry out the car body repair operations described
below :
- spot welding on sheets using a pneumatic clamp,
- welding of sheets using a gun,
- welding of nails, rivets, washers, studs, mouldings,
- repair of bumps and impacts (hail impacts with the pliers option).
1- SD card reader | 6- Fan |
---|---|
2- Interface (MMI) | 7- Power-on switch |
3- Cooling unit | 8- Power cord |
4- Overhanging arm locking support | 9- Filling cap |
5- Filter | 10- Cooling liquid gauge |
DESCRIPTION OF THE G CLAMP (FIG-2)
1- Arm locking/unlocking lever
2- Cooling pipe
3- Gyroscope
4- Pneumatic body
5- Over-opening electrode| 6- Mobile arm
7- Side handle
8- Remote settings button
9- Spot welding button
---|---
Clamp opening : push the button (FIG 2 – 10), the opening of the clamp can be released. The electrode retracts in the clamp leaving a space of 80 mm to access the welding area instead of 20 mm when not in use.
POWER SUPPLY
-
This material is designed to be powered by a 3-phase 400V power supply only (50-60 Hz) with four wires with a neutral one connected to the earth and fitted with a 20 A D-rated circuit breaker (or aM type fuse).
The permanent current absorbed (l1p or ILp) displayed in the section «technical specifications» of this manual relates to use at maximum power.
Check that the power supply and its protection (fuse and/or circuit breaker) are compatible with the current needed by the machine. In some countries, it may be necessary to change the plug to allow the use at maximum settings. -
Power supply recommendations :
In order to limit the voltage drop in the power supply line and to avoid any risk of disconnection of the protection, it is imperative to connect the equipment to a «dedicated» socket. This plug must be connected to the electrical panel and only power this equipment.
When using an extension cord, it must have a length and cross-section appropriate to the voltage of the equipment. Use an extension cord that complies with national regulations.
| Plug 400 V / 3 phases + earth
---|---
L1 : Phase 1
L2 : Phase 2
L3 : Phase 3
**** : Earth (Green/Yellow or green)| • Neutral (not used)
---|---
- The device turns into protection mode if the power supply tension is below or above the 15%. To indicate this default, the screen displays an error code.
- In order to ensure optimal functioning of the equipment, check that the compressed air circuit can supply 8 bar (116 Psi) and then connect the air supply to the back of the machine. The machine must not be used on an air network with a pressure under 4 bar (58 Psi) or over 10 bar (145 Psi).
CONNECTION TO A GENERATOR
The equipment is not protected against the regular overvoltage waves emitted
by the power generator. It is therefore not recommended to connect them on
this type of power supply.
ACCESSORIES AND OPTIONS
REFILL OF THE COOLING LIQUID TANK
The cooling liquid recommended by GYS must be used:
5 l: ref. 062511 • 10 l : ref. 052246
The use of other cooling liquids, especially standard automotive liquid, can
lead, through electrolysis, to the accumulation of solid deposits in the
cooling system, reducing the cooling, and may even lead to system block. Any
damage to the machine caused by the use of another coolant is excluded from
the warranty.
Using purely the recommended coolant provide antifreeze protection down to
-20°C. It can be diluted, but only by using ionized water; do not use tap
water to mix with the coolant! In all cases, at least one 10-litre bottle must
be used to provide minimum protection for the cooling system.
30 litres of liquid (8 US Gal) | protection antifreeze down to -20°C (-4°F) |
---|---|
20 litres of liquid (5 US Gal) + 10 litres of deionised water (3 US Gal) |
protection antifreeze down to -13° (-9°F)
10 litres of liquid (3 US Gal) + 20 litres of deionised water (5 US Gal)|
protection antifreeze down to -5° (23°F)
Any damage resulting from frost will not be covered by the warranty.
To refill the cooling liquid tank, proceed as follows :
- Put the pneumatic clamp on its support.
- Pour 30 litres of liquid (8 US Gal) to reach half of the level indicated.
Safety data concerning the liquid:
- in case of contact with eyes, remove contact lenses if worn and rinse thoroughly using clear water for several minutes. Seek medical advice if complications occur.
- in case of contact with the skin, clean thoroughly using soap and remove any contaminated clothing immediately. Seek medical advice if the skin gets irritated.
- in case of the liquid being swallowed, rinse the mouth abundantly using clear water. Drink plenty of water. Seek medical advice.
Maintenance : See chapter «PRECAUTIONS AND MAINTENANCE».
STARTING THE MACHINE
- Start the machine by switching the switch on ON (Fig 1 – 7), and stop it by switching to OFF. Warning! Never disconnect the power supply when the welding electrical distribution is in operation. The PCB inside the machine starts a test cycle and initiate the settings which takes around 10 seconds. At the end of that cycle, the machine is ready to be used.
- As soon as the machine is powered, the liquid starts circulating in the cables. check for potential leaks.
MAN TO MACHINE INTERFACE
1 Button
- Push briefly the button to choose between the modes clamp, gun or «clamp settings».
- Push the button for 2 seconds to return to the «normal» mode from all the other modes.
- Push the button for 2 seconds to reset the spot count when it is on display.
- Push the button for 2 seconds to return to the «Settings» menu.
- Push briefly twice to erase the log displayed in the log view mode.
- Push briefly the button, in the programs saving mode, erase the program selected.
2 Saving a report
This function is detailed in the corresponding chapter.
Button activates or deactivates the creation of a report.
Button is used to view the points completed.
3 Using the different modes
Button is used to move through the different welding modes. A prolonged push
on the mode button activates the settings mode used to select the language,
set the date and activate the warning sound for «current too low» or «pressure
too low». Buttons are used to navigate through and select the value that needs
to be adjusted, and then buttons + and – are used to increase or decrease that
value.
4 Saving the settings
- Button is used to save a machine setting (these are the settings that have been adjusted through the manual mode : current, duration and tightening).
- Button is used to re-establish a setting saved previously under the same name. The machine starts automatically in manual mode using the welding settings (current, duration and tightening) and the tool (clamp or gun saved).
5 Setting the thickness of the plate
The value to be entered is in relation to the thickness of the sheets being
welded on. The selection of the thickness is done using the + and – buttons,
the different thicknesses available are 0.6, 0.8, 1.0, 1.2, 1.5, 1.8, 2.0, 2.5
and 3.0 mm.
6 Setting the type of plate
This setting is used to specify the type of metal plate being welded on, the
different choices are : coated steel, HLE/THLE steel, UHLE steel and
bore/USIBOR steel. This setting can also be adjusted using the + and –
buttons.
7 Setting up the arm
SETTING UP THE G CLAMP
Lock the G arm in place using the lever (FIG 2 – 1).
Use the button
in order to select the clamp setting function. The «clamp setting» function is
used to close the clamp and to apply the pressure pre-selected at the
electrodes without power going through. The clamp remains closed while the
trigger is pressed. This function is designed to verify the centering of the
end bits.
Push the button for 2 seconds to return to the AUTO mode. For the GYSPOT PTI
S7,, always ensure to be in that mode to stop the pump when changing the arms.
The electrode retracts into the clamp. The red indicator on the button lights
up when the pump stops.
THE DIFFERENT WELDING MODES
For all the models :
The buttons are used to select the settings that need to be adjusted. Each
adjustment is done by pressing the side keys + and –.
The button on the clamp is used to remotely adjust the welding settings
(thickness, type of steel) :
- Long push : change of setting (to go from one setting to another)
- Short push : modification of the value
This button does not allow to change the arm on the screen. To change the arm
(C1 to C2 for instance), the user must use the machine keypad.
Insufficient network pressure :
If the input pressure is insufficient to provide the correct pressure, the
machine shows an error message before the weld «Insufficient network pressure»
. Pressing the trigger a second time is used to «force» the spot weld using
the available pressure.
Low current :
If the current obtained during the spot weld is below the expected value (<6
%), the machine displays «low current» after the weld which means that the
weld must be checked.
In any case, a message is displayed at the end of the weld indicating the
current and pressure measured. This message remains on display on the screen
until the user pushes a button on the keypad or carries on welding.
The welding conditions must be reviewed at the start of each new job. «Test»
weld spots must be carried out on metal panels or sheets similar to the new
job being undertaken. Carry our two spot weld with appropriate space in
between, in line with the requirement of the job. Test the strength of the
second weld. The test is successful if, when pulling the spot out, the panel
breaks and the centre is extracted. The centre must have a minimum diameter in
line with the specifications of the make of the vehicle.
AUTO mode
This mode is displayed by default when the machine starts.
This mode is used to weld sheets/panels without having to specify any settings
on the screen. The machine sets the appropriate settings automatically.
In order to use this mode, do a blank spot weld (without any sheet/panel
between the electrodes),as prompted on the display. Push the button. The
message «Do a spot without a load» is displayed on the screen. Push the button
again to calibrate. Once the calibration is done, the machine shows all the
settings to zero, and is ready to weld. Close the clamp on the area to weld
and weld automatically, without entering any parameters in the machine. Every
30 spots, a new calibration will be required.
This mode can be used when using all arms except the C10.
NORMAL mode
This mode determines the welding settings based on the thickness of the
sheets/panels and the type of steel.
The settings that need to be set when using this mode are:
-
Thickness of the sheets/panels, with a range between 0.60 mm and 3.00 mm. When 2 sheets/panels are being welded together, enter the thickness of the thinnest sheet.
When 3 sheets/panels are welded together, use the total cumulated thickness and divide by 2. -
Type of steel (coated steel, HLE/THLE steel, UHLE steel, bore steel (BORON)). When welding a mix of different types of steel, select the strongest one.
-
Reference of the arm used.
Push the button for 2 seconds to return to the AUTO mode.
MANUAL mode
This mode is used to select the parameters of the spots by following the
instructions of a repair book.
The parameters to set in this mode are:
- Current
- Duration
- Pressure
- Reference of the arm used.
Push the button for 2 seconds to return to the AUTO mode.
MULTI mode
This mode is used to set precisely the thickness and type of steel for each
sheet/panel .
The first element (thickness of sheet 1) is selected. The keys up and down are
used to select the setting that needs to be adjusted, where the keys right and
left are used to increase or decrease the value. Highlight the setting that
needs to be adjusted.
The settings that need to be set when using this mode are:
- Thickness of the sheets/panels, with a range between 0.60 mm and 3.00 mm.
- Type of steel (coated steel, HLE/THLE steel, UHLE steel, bore steel (BORON)). When welding a mix of different types of steel, select the strongest one.
- To activate the sheet/panel 3, press the scroll keys to highlight sheet/panel 3. Then use they keys + and – to select the thickness of the sheets/panels.
- Reference of the arm used.
Push the button for 2 seconds to return to the AUTO mode.
GYSTEEL mode
The GYSTEEL mode is optional; it can be modified using the « Settings» menu.
This mode is similar to the standard mode except that the user enters the
elasticity of the metal (Re). This value «Re» can be found using a tool like
the GYSTEEL Vision.
Re : 1-10 is for mild steels.
Re : 11-18 is for HLE/THLE steels.
Re : 19-35 is for UHLE steels.
Re : 36-99 is for bore/boron steels.
The settings that need to be set when using this mode are:
-
Thickness of the sheets/panels, with a range between 0.60 mm and 3.00 mm.
When 2 sheets/panels are being welded together, enter the thickness of the thinnest sheet.
When 3 sheets/panels are welded together, use the total cumulate thickness and divide by 2. -
Reference of the arm used.
Push the button for 2 seconds to return to the AUTO mode.
MANUFACTURER mode
The MANUFACTURER mode is optional; it can be modified using the « Settings»
menu. This mode is used to name a pre-registered spot based on the repair book
issued by the manufacturer.
Spot welds programmed by the user can be recalled by selecting USER in the
manufacturers list. Welding spots can be programmed using the GYSPOT software
and the welding spots settings module.
Push the button for 2 seconds to return to the AUTO mode.
ENERGY mode
The ENERGY mode is optional and can be set using the «Settings» menu.
This mode is used to control the energy transmitted during the weld. This mode
is not designed to be used during repairs but for the benefit of manufacturers
and quality control organisations conducting tests.
To enable this mode, first perform a weld without a load. Push the button (FIG
2 -11). The message «Do a spot without a load» is displayed on the screen.
Push the button again to calibrate. Once the calibration has been done, the
machine displays the last values used in this mode for current and energy. The
use can then modify the welding current, energy and resistance. The duration
of the weld will vary based on the time required for the machine to reach the
energy level required. If it is taking too long, the machine will display the
error message «maximum duration reached».
Push the button for 2 seconds to return to the AUTO mode.
SETTINGS MENU
This menu is accessible by pressing and holding the button for 2 seconds.
The language used in the menu can amended on line 1.
The date and the time can be programmed on line 2.
The modes GYSTEEL, MANUFACTURER , AUTO, ENERGY, NORMAL et MULTISHEETS can be
activated or deactivated using this menu.
daN control :
This setting allows you to activate or control the clamping force of the clamp
during a weld.
GLUE mode:
On the SETTINGS screen below, the user can specify the presence glue between
the panels/sheets. When this mode is in use, a pre-spot is performed before
the weld. The duration of this pre-spot is set in milliseconds, from 0 to 400
ms, with 50 ms thresholds. When the glue mode is selected, word « GLUE » is
displayed in the menus of the NORMAL, MANUAL, MULTI or GISELE welding modes.
USE OF THE GUN (OPTION)
- Select the GUN tool using the button
| Attach the
gun grounding cable to the mobile electrode. Slide and tighten the knurl.
---|---
Remove the arm from the clamp and fix, in its place, the gun cable.
Connect the control cable to the jack plug.
Check that the screw connecting the shoe to the cable lug is tight.
-
Fix the earth pad firmly and as close to the weld as possible.
In the case of a monopoint weld, always place the earth on the sheet/panel that is not in contact with the welding electrode (in order for the current to go through the two sheets to be welded). -
Weld starting with the furthest spot away from the earth and work towards it.
-
The normal welding mode using the stars is the one used by default.
-
The gun can be used in normal or manual mode.
In normal mode, the gun will be limited to 1.5mm thick sheets.
Using the gun, the operator can choose between different tools (mono point,
star, impact, heat, dowel pin, rivet, nut, toothed wheel). Select the desired
tool using the + and – keys.
In Manual mode, the maximum possible intensity is 8 kA for a maximum duration
of 500 ms. The settings showing on the screen will not exceed these values.
Set the generator by indicating the thickness of the sheet/panel to weld using
- and – keys. It is possible to adjust the current and time settings when in
manual mode.
Press the button for 2 seconds to get back to the NORMAL mode.
ERROR MANAGEMENT
Various elements may produce errors. They can be split into 4 categories :
-
Warning messages designed to warn the operator of overheating, lack of pressure or power, etc.
These messages are displayed on the screen and remain visible until a button is pressed. -
The faults that occur in relation to insufficient air pressure or power supply.
-
The serious faults that block the machine. In this case, contact the service department
-
The thermal protection is linked by a thermistance on the diode bridge and when it activates the machine is locked and the message «overheating» is displayed.
Low battery
The message «Battery low» is displayed when the machine is switched on and it
indicates that the battery on the command board is low. This battery is used
to record the date and time when the machine is switched off.
Invalid tool
Invalid arm
The arm used is not compatible with the welding mode selected.
Current too low
-
Check the weld
If the current obtained during a spot weld is lower than the expected value (6%), the machine displays the warning message «Low current, check the weld». -
Check the sheets
If the machine cannot deliver the current required, the error message «Low current, check the sheets» is displayed. The weld does not happen and the fault must be skipped for the weld to happen.
Insufficient air pressure
If the input pressure is insufficient to deliver the tightening requested, the
machine beeps and displays, before the weld, the error message «Insufficient
air pressure».
Pressing the trigger a second time is used to «force» the spot weld using the
available pressure. If the tightening recorded is insufficient, the machine
displays «Low pressure».
«p low» is also recorded in the active report.
SPOT COUNT
A spot count tool keeps count of the different spot weld done using the same
cap. If there is no problem during the welding, the following message is
displayed.
The count is displayed at the top left corner of the screen. Press the button
for 2 seconds to
reset the count after changing the caps.
The machine counts the number of points achieved with each arm independently.
A warning message appears on the screen when the limit of the points made by
the headings is reached. The message remains displayed after each point until
the counter is reset.
If the caps are not changed after the warning message is displayed and the
count is simply reset, they can deteriorate and have a negative impact on the
quality of the weld.
RECORDING FEATURES
The Identification mode is optional and can be activated using the «settings»
menu.
If the identification mode is switched off, just enter a report name and
activate it to memorize the weld points made.
The log allows to store the parameters of the spots made using the clamp. It
is available in all the modes by pressing the 2 buttons and .
The user program is available in all modes by pressing the and buttons.
Report (log)
Saving a report allows you to retrieve the data of a series of spot made
with using the clamp, and to save them on the memory card so that they can be
retrieved from a PC for example. GYS provides a software called GYSPOT to read
the SD card and edit the logs on a PC. This GYSPOT software is stored on the
SD card as well as the user manual.
By default, this feature is disabled when the machine is switched on. Pressing
the recording button (on/off) and the «mode» button starts recording the
report in the selected log. Pressing the record button again (on/off) stops
the current recording.
The log created contains: an ID entered by the user, as well as for each spot
performed, the tool and arm used, the machine settings (power and pressure).
It also contains the following possible error messages that may have occurred
during its recording: I LOW, P LOW, PB CAPS.
The ID is entered using the 4 keys +, – . When entering an identifier already
in use, the machine will record the new points in succession, without deleting
the previous ones.
The button is used to retrieve a previously saved report and read it back on
the screen.
The current recording must be stopped by pressing the button before it can be
displayed on the screen. The button is used to exit the report view mode.
To delete the contents of a report, you must
display it on the screen using the button .| Then press the button.
The following message appears on the screen.
---|---
|
When the triangle is displayed, a second press on the button erases the
content of the report displayed.
The triangle disappears from the screen automatically after 3 seconds.
Identification mode
If the identification mode is set to «ON», all mandatory fields in the repair
order must be entered to allow the weld to go ahead or the machine will
display «identification fault».
To activate and deactivate the identification mode, an SD identification card
must be inserted in the BP card reader instead of the SD card containing the
programs.
The settings screen is activated by pressing and holding down the button for 2
seconds.
When the SD card «identification» is inserted and «identification ON» is
selected, the supervision screen is displayed.
This screen is used to make the fields «registration, vehicle make, vehicle
model, vehicle model, chassis number» mandatory fields when entering the
repair order.
To exit the screen, press the button for 2 seconds. Then, it is necessary to
put the SD card containing the programs back into the machine card reader.
List of screens used to enter a repair order :
If a repair order has already been created, it cannot be changed or deleted on
the machine. To delete it, use the Gyspot software on the PC. The user can
create a maximum of 100 repair orders.
The arrow keys are used to change the letters or numbers. The keys – and + are
used to move the cursor inside the field. Press the button briefly to clear
the field. The button allows you to scroll through the fields for editing or
reading.
Catalogue
The button is used to consult the repair orders. The page number is displayed
(max. 13)
The keys – and + are used to change pages. The keys are used to select
previous or next job. The button displays the selected repair order.
The button key is used to exit the report view mode.
- The SD card management library allows you to manage your SD cards over 2 GB..
- For each repair order, a log file xxx.dat is associated (with xxx=identifier from 001 to 100). In each log, a maximum of 500 welding points can be recorded. On consultation, the names of the repair order and the user are displayed.
- The page number is indicated at the top left..
- All repair orders are stored in the file called catalog.GYS.
- This file contains the total number of repair orders, the name of each repair order and the name of each user. There is a maximum of 100 repair orders.
User programs
Saving the settings allows you to define a user program in order to easily
find its settings for future use. 20 memory slots are available. Each of them
contains the following settings: tool, arm, welding power, welding time and
pressure.
A program can be associated to the clamp or gun.
The button is used to save the current settings of the manual mode (power,
time and pressure). The 20 memory slots are then indicated by their identifier
(for those used) or by a symbol» —» for free slots..
The ID is entered using the 4 keys . When entering an ID that has already been
used, the machine will delete the settings that were previously stored.
The button is used to access the settings previously saved. Choosing an empty
location has no effect.
Briefly pressing key deletes the selected program from the list of saved
programs.
The key exits the program selection mode, switches the machine to manual mode
with the parameters and tool saved in the program.
To deactivate a program, simply change the value of a parameter in one of the
three modes manual, normal or multiplane or change the tool (clamp, gun) using
the button.
The key allows you to view a previously saved report and read it back on the
screen.
SD memory card (ref. 050914)
This card allows the user to link the machine to a PC in order to:
- Retrieve logs (reports), keep a record of the work done, and eventually send it to an insurance company.
- Update welding parameters, add new languages.
- The GYSPOT software for editing parameters on a PC is stored on the SD memory card.
- The instructions are is stored on the SD memory card.
The memory space is sufficient to ensure an autonomy of more than 65,000
points.
The machine can operate without a memory card in «manual» mode only.
If the memory card is not inserted in the card reader, the following message
appears. The machine must be stopped and restarted after inserting the SD
card.
Important : It is necessary to turn off the power to the machine before
removing the SD card from its reader and restart the machine only after
inserting the SD card into its
reader, otherwise the data saved on the SD card may be lost.
REPLACEMENT OF C ARMS
Please read the following instructions carefully.
Incorrectly tightening or setting the C clamp arms can lead to the arm and
clamp overheating and causing damage.
Damage caused by incorrect assembly are not covered under the warranty.
-
Switch off the machine, or put the machine into « clamp setting » mode.
-
Unscrew screw (1) which holds the arm to the clamp.
Leave it on the arm to not lose it. -
Disconnect the cooling liquid pipes.
-
Unscrew screw (2) and loosen the lever (3) on the side of the clamp.
- Remove the clamp arm.
- Lubricate both a new arm and the support with contact grease (ref.050440).
Specific Installation for C2 and C8 arms
For these arms, the Stretches will also need to be changed. Unscrew the short
stretches with a flat
spanner and remove the injector. Centre the injector along the axle of the
clamp (Caution: beveled side outside) and insert it manually(1)
Position the long stretches in front and screw it on to the clamp axle
(maximum torque 15Nm) (2).
Stretches types:
Short: C1, C3, C4, C5, C6, C7, C9, C10 Long: C2, C8
ADJUSTMENT OF C ARMS
- Position screw (4) to fix the arm on the clamp. Tighten it in manually – do not overtighten.
- Tighten ring (5) manually, then the tighten (6) using the Allen key.
- Tighten the lever manually and check it is not end up against the joint stop (see diagram below). If it is the case go back to step previous.
Warning: Clamp and arm may be damaged if the lever is not tightened properly.
- Check the cooling liquid level.
- Check screws and lever, incorrectly tightening can damage the material.
- Switch on the machine.
C CLAMP OVERHAUL
The tightening of the following screws need to be inspected every month:
Screw between the arm and the clamp:
These 4 screws fix the arm to the clamp. They need to be tightened to have a
good transmission of the current. A bad tightening leads to a loss of current,
and worst can damage your arm or clamp irreversibly.
CONNEXION GYSPOT / C CLAMP :
B : Black
G : Green
W : White
Y : Yellow
THE GYROSCOPE
Fix the gyroscope with 4 screws M5 x 12.| It can rotate around the clamp at a
360° angle.
---|---
|
GYSPOT SOFTWARE ON PC
The purpose of this software is to edit and save the spot weld reports made
using a GYSPOT equipped with an SD card reader. To use this software, the PC
must be equipped with an SD card reader.
The GYSPOT software can be installed from files on the SD card. In the
directory \GYSPOT V X.XX, double click on the file INSTALL.EXE, and follow the
instructions to install the software on your PC. A GYSPOT icon is
automatically installed on your PC desktop.
-
Language selection
The software supports several languages. Currently, the available languages are:
French, English, German, Spanish, Dutch, Danish, Finnish, Italian, Swedish, Russian, Turkish.
To select a language, from the menu, click on Options and then on Languages.
Note that once the language has been selected, it is necessary to close and open the GYSPOT software again so that the language can be taken into account. -
User identity
In order to personalise the editions with your personal information, some information is required. To give the required information, in the menu, click
on Options then on Identity. A new window appears with the following information:
Company name
Address / Post code / City
Telephone / Fax / Email / Website
Logo
The information will then be displayed on the editions. -
Traceability
By default, the GYSPOT software opens in «Traceability» mode. In «Point Setting» mode, click on Traceability in the Options menu.
3.1 – Importing point reports from an SD card :
To import the point reports made with a GYSPOT into your PC, insert the SD card into the card reader on your PC and start the GYSPOT software.
Then select the reader into which your SD card is inserted and click on the button .
When the import is performed, the weld spots performed are grouped by the maintenance order identifier. This identifier corresponds to the name of the report specified in the welding machine. This identifier is displayed in the Current tab.
Once the reports have been imported, it is possible to search, edit or archive each report. To visualise the spot completed in a report, select a report. The spots completed are displayed in the table.
To perform a search, fill in the search field and click on the button .
To edit a report, select a report and click on the button .
To archive a report, select a report and click on the button . Warning, please note that imported reports cannot be deleted until they have been archived.
3.2 – Consult the archived spot reports:
To view the archived reports, click on the Archives tab. The reports are grouped by year and month.
To view the spots completed, select a report. The spots completed are displayed in the table.
For archived reports, it is possible to search, edit or delete a report.
Be careful, a report archived and then deleted will be imported again when importing data from an SD that has not been cleared.
To perform a search, fill in the search field and click on the button .
To edit a report, select a report and click on the button .
To delete a report, select a report and click on the button .
3.3 – Clearing an SD card:
Clearing the card will erase all completed spot reports recorded on the SD card.
To clear an SD card, insert the SD card into the PC card reader and then, in the menu, click on Options and purge the SD card.
Be careful, when clearing, the spot reports completed that have not yet been imported will be automatically imported.
3.4 – To complete the information in a report:
Each report can be filled in with the following information:
Operator,
Type of vehicle,
Repair order,
Registration,
Date of first registration,
Intervention,
Comments.
To enter this data, select a report and enter the information in the report header.
3.5 – Printing a report :
To print a report, select a report and click on the button . A preview of the edition is displayed. Click on the button .
3.6 – Exporting the edition in PDF format:
To export an edition in PDF format, select a folder, then click on the button . A preview of the edition is displayed. Click on the button .
An example of saving the parameters printed using the GYSPOT software is given below. -
Spot parameters
To switch to «Spot Parameter» mode, click on Spot Parameter in the Options menu.
The «Spot parameter» mode allows to use the operator to use spots set by the manufacturers. This mode also allows the user to choose his own welding parameters.
– Insert the SD card supplied with the GYSPOT spot welder into the reader of your PC and select the correct disk in the drop-down menu.
– GYSPOT spot welders support up to 16 files that can contain up to 48 spot settings.
– The first file called «USER» cannot be deleted. It allows the user to add, modify or delete a spot parameter.
– The other files are reserved for the spot set by the manufacturers.
4.1 – Import a manufacturer spot parameter file :
Double-click in the first column and enter a manufacturer name.
Then double-click in the second column to select a manufacturer file previously downloaded from our website.
The list of spots set by the manufacturer is displayed in the second list.
Select a configured point to view the chronogram and configured parameters.
4.2 – Add a configured spot in the USER file :
To add a spot to the USER file, select the USER file from the file list and
click on the button to the right of the list of configured spots. Enter the
name of the spot and press the TAB key or click outside the list of configured
spots to configure the welding parameters.
For a spot to be configured, it is possible to configure:
The pre-tightening stage
The pre-heating stage
The different pulses (4 pulses maximum)
And the hot and cold forging stage.
To change the settings, click on the buttons .
When the operator changes a parameter, the spot chronogram is updated.
To validate the spot configuration, click on the button .
To cancel the spot configuration, click on the button .
4.3 – Modify a spot configured in the USER file:
To change the settings of a spot, select a spot from the list and then change
the welding settings.
To validate the changes, click on the button .
To cancel the changes, click on the button .
4.4 – Delete a configured point in the USER file:
Select a spot parameter from the list and click on the button to the right of
the list.
| Raison sociale :
Adresse :
Code postal :
Ville :| JBDC
ZI, 134 Bd des Loges
53941
Saint-Berthevin| Téléphone :
Télécopie :
Email :
Site Web :| 0243510101
0243510102
contact@companyname.com
www.companyname.com
---|---|---|---|---
Intervenant :
Ordre de réparation :
Date du journal :
Intervention :
Commentaires :| OPERATEUR
977AC92
05/04/2018
AILE ARRIERE
Commentaires| Modèle :
Marque :
N° châssis :
Immatriculation :
Mise en circulation :| 308SW
PEUGEOT
12365849
1450UT53
01/01/2017
---|---|---|---
GYSPOT BP.LG (1712009013)
Id| Date| Mode| Outil| Consignes| Mesures|
Etat
---|---|---|---|---|---|---
Temps
(ms)| Intensite (kA)| Serrage
(daN)| Intensite (kA)| Serrage
(daN)| Epaisseur
(mm)
1| 05/04/18 10:22| Auto| Pince en C n°1| 630| 9,4| 325| 9,4| 325| 3,5| Point
Ok
CV| 05/04/18 10:22| Auto| Pince en C n°1| 630| 9,4| 325| 9,3| 325| 3,5| Point
Ok
CO| 05/04/18 10:22| Auto| Pince en C n°1| 490| 8,2| 240| 8,2| 240| 2,0| Point
Ok
•zt| 05/04/18 10:22| Auto| Pince en C n°1| 510| 8,3| 250| 8,2| 245| 2,1| Point
Ok
LO| 05/04/18 10:22| Auto| Pince en C n°1| 510| 8,3| 250| 8,3| 245| 2,1| Point
Ok
CD| 05/04/18 10:23| Normal| Pince en C n°1| 350| 7,3| 225| 7,3| 225| –| Point
Ok
N-| 05/04/18 10:23| Normal| Pince en C n°1| 350| 7,3| 225| 7,2| 225| –| Point
Ok
CO| 05/04/18 10:23| Normal| Pince en C n°1| 400| 8,1| 265| 8,0| 265| –| Point
Ok
0)| 05/04/18 10:23| Normal| Pince en C n°1| 400| 8,1| 265| 8,1| 260| –| Point
Ok
10| 05/04/18 10:23| Normal| Pince en C n°1| 400| 8,1| 265| 8,1| 270| –| Point
Ok
11| 05/04/18 10:23| Manuel| Pince en C n°1| 400| 8,1| 510| 8,1| 440| –|
Pression faible
SAFETY AND MAINTENANCE
User training
People operating this machine must receive suitable training in order to get
the most out of the machine capabilities and carry out good quality repairs
(examples: car body work training).
Preparation of the parts to be assembled
It is essential to clean and accost the area to be welded.
In the case of a protective application, make sure that it is conductive by
first testing a sample.
Monopoint electrode welding
When repairing a vehicle, check that the manufacturer allows this type of
welding process.
Using the underwing arm
The maximum pressure is 100 daN.
Quantity and quality of the coolant
The coolant level is important for the correct operation of the machine. It
must always be between the minimum and maximum level indicated on the trolley.
Top up with demineralized water if necessary.
Replace the coolant every 2 years :
TROUBLESHOOTING
| TROUBLESHOOTING| CAUSES| SOLUTIONS
---|---|---|---
Clamp welding| The spot made does not hold or does not enough| The caps are
worn out.| Change the caps.
The sheets are not clean enough.| Check the preparation work.
The arm selected does not match the one mounted.| Check the arm selected in
the software.
The machine makes a hole in the sheet.| The caps are worn out.| Change the
caps.
Insufficient air pressure.| Check the air pressure (min. 8 bar)
The surface is not properly prepared.| Prepare/clean the surface to be worked
on
Lack of power| Power supply problem.| Check the stability of the mains voltage
Caps blackened or damaged.| Change the caps.
Incorrect arm locking.| Refer to the chapter “Assembly and changing the arms”.
– Fast overheating of the machine. – Power cable inflation.| .
No or poor circulation of the coolant.| Open the cart tank cap and observe the
movement of the coolant and correct return.
unD| Abnormal heating of the gun| Incorrect tightening of the chuck.| Check
the tightness of the chuck, the star holder chuck, and the condition of the
sheathing.
Gun sheathing loose.| Replace the sheathing in order for the air cooling to
reach the inside of the gun
Incorrect positioning of the earth pad.| Check that the ground pad is in
contact with the right sheet metal.
Lack of power in the gun| Poor contact of the earth pad.| Check the earth
contact
Incorrect tightening of the chuck or acces- sories.| Check the tightness of
the chuck and accessories, and the condition of the sheathing
Damaged consumables.| Replace the consumables
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase
(parts and labour).
The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping of equipment, disassembling).
- Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc …)
- A description of the fault reported
SPARE PARTS
| 400V-4m| 1400V-6m
---|---|---
1| Hose clamp| 71195
2| Primary thermal protection circuit| 9706K
3| Derivacion| 77060
4| Angled male fitting| 71482
5| Diode bridge| 94337
6| Linear potentiometer| 63090
7| Copper gasket| 71318
8| Cylindrical male coupler| 71317
9| Arm support| 581091
10| Push-button| 51381
11| Illuminated push button| 51408
12| Woven protective sheath| 11251
13| Green polyurethane hose| 94664| 94665
14| Yellow polyurethane hose| 91623| 91617
15| 4.09 meter black braided hose| 91628| 91611
16| 3.84 meter black braided hose| 91629| 91610
17| 3.97 meter black braided hose| 91733| 91734
18| Control cable| 94865ST| 94866ST
19| Power cable| 91724SF| 97123SF
C (C1/C2/C3/C4/C5/C7/C8/C9/C12)
| C
---|---
1| Type A13 caps| 77027
2| BS ring M6| 71385
3
| C1 = Hose| 94572
C2 = Hose| 94573
C3 = Hose| 94574
C4 = Hose| 94575
C5 = Hose| 94585
C7 = Hose| 94577
C8 = Hose| 94574
C9 = Hose| 94579
C12 = Hose| 94573
4| Arm lock pin| 062405
C6
| C 6
---|---
1| 4 position electrode| 77027
2| Hose| 71385
3| Arm lock pin| 94572
C10
| C 6
---|---
1| 4 position electrode| 77027
2| Hose| 71385
3| Arm lock pin| 94572
C11
| C 6
---|---
1| 22° inclined caps| 77029
2| Hose| 94656
3| Hose| 94674
4| Hose| 94657
5| Injector| 77086
6| O-ring seal| 55121
7| Clamp extension C11| 90622
C14
| C 6
---|---
1| Type A13 caps| 77027
2| Instantaneous connection| 55138
3| Hose| 93803
4| Arm lock pin| 062405
5| Coupling nipple with shut-off valve and D6 AIRFIT push-in connector|
55235
Option
| Pistolet
---|---
1| Cable gun| A0069
2| Ground cable| A0070
1 | Filling cap | 71327 |
---|---|---|
2 | Flüssigkeitbehälter 38 Liter | 71759 |
3 | Pump | 71772 |
4 | Stiller Block | 71136 |
5 | Rotating wheel | 71362 |
6 | Radiator | 71750 |
7 | Fan | 51014 |
8 | Wheel axle | 98128ST |
9 | Wheel axle end cap | 71382 |
10 | Rear wheel | 71376 |
Generateur 400 V
1 | SD card circuit | 97028C |
---|---|---|
2 | Transformator | 96019 |
3 | Power board | 97027C |
4 | Control card | S97085 |
5 | IGBT module | 52200 |
6 | Diode bridge | 52194 |
--- | --- | --- |
7 | Contactor | 51131 |
8 | Regulation filter | 71462 |
9 | Switch | 52344 |
10 | 2-way solenoid valves | 71538 |
11 | 3-way solenoid valves | 71537 |
12 | Display LCD | 51905 |
13 | Keypad | 51910INDX |
14 | Ribbon connector | 53100 |
15 | 4-wire harness | S91551 |
CABLE ASSEMBLY SCHEMATICS
CIRCUIT DIAGRAM
TECHNICAL SPECIFICATIONS
| PTI-s7 – 400 V
---|---
Electrical specifications
Nominal supply voltage| U1N| 3~ 400 V
Mains frequency| F| 50 / 60 Hz
Permanent power supply| ILP| 19 A
Power at 50% duty cycle| S50| 19 kVA
Permanent stable power| Sp| 13.2 kVA
Instant peakl power| Smax| 110 kVA
Secondary voltage| U2d| 7.3 V
Maximum permanent primary short-circuit current| ILCC| 159 A
Secondary current in short-circuit| I2cc| 14 500 A
Continuous secondary current| I2P| 1 750 A
Disjoncteur ou fusible (aM)| | 20 A (Type D)
Différentiel| | 30 mA
Duty cycle| | 1.45 %
Fusible F2| | 5×20 mm| T4A – 250 VAC
Fusible F4 (ref. 051409)| | 5×20 mm| T5A – 450 VDC
Thermal specifications
Operating temperature| | 5°C → 40°C
+41°F → __ +104°F
Storage temperature| | -25°C→ +55°C
-13°F → +131°F
** Hygrometry| @ 40°C
(104°F)| | < 50 %
@ 20°C (68°F)| | < 90 %
Altitude| | 1 000 m
3800 ft
Thermal protection by thermistor on the diodes bridge| | 70°C
158°F
Mechanical specifications
Protection level| | IP20
Dimensions (Lxlxh)| | 65 x 80 x 230 cm
Weight | | 92 kg
Network cable length| | 8 m
26 ft
clamp cable length| | 4 m / 6 m
13 ft / 20 ft
Arm aperture dimension| **| 40 > 450 mm
1.6 to 18 inch
Arm length dimension| **| 20 > 600 mm
0.8 to 24 inch
Pneumatic specifications**
Maximum pressure| P1 max| 10 bar
145 Psi
Minimum pressure| P1 min| 8 bar
116 Psi
Cooling liquid debit| Q| 1 l/min
0.26 US gpm
---|---|---
Loss of cooling liquid| ∆p| 3 bar
44 Psi
Minimum welding force| F1min| 100 daN
225 Lbf
Maximum force regulated with the C clamp| Fmax| 550 daN
1236 Lbf
SYMBOLS
**** | – Warning ! Read the instructions manual before use. |
---|---|
**** | Direct welding current |
A | Ampere |
V | Volt |
Hz | Hertz |
**3∼** | – Three-phase power supply 50 or 60Hz |
U 1N | Instructed supply voltage |
U LP | Supply current to secondary continuous current |
S P | Permanent power (at a 100% duty cycle) |
S 50 | Power at 50% duty cycle |
U 2d | Continued no load voltage |
I 2 CC | Maximal current of a secondary short circuit |
I 2 P | Permanent current to secondary |
e | Arm aperture dimension |
∫ | Arm length dimension |
F max | Maximum welding force |
P 1 min | Minimum input pressure |
P 1 max | Minimum input pressure |
Q | Cooling liquid debit instructed |
∆p | Loss of charge of the cooling liquid instructed |
m | Mass of the machine |
**** | Cooling unit |
**** | Water outlet |
**** | Water inlet |
MAXI | Maximum water level |
MINI | Maximum water level |
People wearing pacemakers are advised to not come close to the machine. | |
--- | --- |
Warning! Major magnetic field. Persons with active or passive implants must |
be informed
| Do not use the machine in the open air. Do not project water onto the
machine.
| Device complies with Europeans directives. The EU Declaration of Conformity
is available on our website (see cover page).
IEC 62135-1
ISO 669:2016| This welding machine is compliant with standard IEC 62135-1 et
EN ISO 669.
| The machine is compliant with standard 2013/35/EU.
| This hardware is subject to waste collection according to the European
directives 2002/96/UE. Do not throw away in a household bin!
| This product should be recycled appropriately
| EAEC Conformity marking (Eurasian Economic Community).
| Equipment in compliance with British requirements. The British
Declaration of Conformity is available on our website (see home page).
| Equipment in conformity with Moroccan standards. The declaration Cم) CMIM)
of conformity is available on our website (see cover page).
****| Temperature information (thermal protection)
SAS GYS
1, rue de la Croix des Landes
CS 54159
53941 SAINT-BERTHEVIN
France