EXTOL 8820043 Digital Laser Distance Meter User Manual
- June 3, 2024
- EXTOL
Table of Contents
- EXTOL 8820043 Digital Laser Distance Meter
- Introduction
- Technical specifications
- Safety warnings and information
- Inserting batteries / Display / Buttons
- DISPLAY
- BUTTONS
- Turning on / turning off / setting a reference point
- Measurement modes
- Saving and viewing
- Error signals on the display
- Calibration
- Maintaining and storing the device
- Label and pictograms on the label
- Waste disposal
- Warranty and service
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
EXTOL 8820043 Digital Laser Distance Meter
Introduction
Dear customer,
Thank you for the confidence you have shown in the Extol® brand by purchasing
this product.
This product has been tested for reliability, safety and quality according to
the prescribed norms and regulations of the European Union. Contact our
customer and consulting center for any questions at:
www.extol.eu
service@madalbal.cz
Manufacturer: Madal Bal a. s., Průmyslová zóna Příluky 244, 76001 Zlín, Czech Republic. Date of issue: 27. 11. 2017
Technical specifications
- Measurement range: 0.05-40 m (model 8820042)
- 0.05-80 m (model 8820043)
- Minimum resolution: 1 mm
- Measurement accuracy 1): ± 1.5 mm to 10 m
- Available measuring units: m/in/ft
- Continual measurement function: yes, min/max. value
- Area measurement function: yes
- Volume measurement function: yes
- Measurement function according to Pythagorean theorem: yes, 4 calculation functions
- Addition and subtraction function: yes
- Max. number of saved values: 100
- Automatic display backlight: yes
- Press button sound: yes
- Thread for tripod attachment (underside of the device): 1/4” (6 mm)
- Protection: IP54
- Laser class: 2
- Wave length and laser power: 635 nm, <1 mW
- Automatic laser shut-off: 20 s
- Automatic shut-off: 150 s
- Storage Temperature: -10 °C – 45 °C
- Operating temperature: 0 °C – 40 °C
- Storage humidity: Relative humidity 80 %
- Batteries: 2× AAA 1.5 V batteries
- Battery operating lifetime 2): 8 000 measurements in single measurement mode
- Weight (with batteries): 128 g
- Dimensions: 118 × 54 × 26.5 mm
- Measuring inaccuracy will increase by ± 0.25 mm in the distance measurement distance of 10-25 m. At a distance over 25 m, the inaccuracy will increase by a further ± 0.25 mm. Intensive sunlight, transparent materials (clean water or colorless glass), small reflectivity of the measured surface or large temperature differences may reduce measurement accuracy. When the temperature of the measured surface is high, inaccuracy may increase by ± 1.5-2 mm.
- The battery lifetime depends on the quality of the batteries used, the storage/operating conditions of the device and the operating time of the device.
Safety warnings and information
- Before using this device, please read the safety instructions and the user’s manual.
- Before use, please read all operating instructions and safety directives in this user’s manual. Incorrect use and not adhering to the instructions contained in this manual may result in damage to the device, affect the measurement results or cause injury to the user.
- This device must under no condition be disassembled or modified. Any unauthorised modifications or power output changes are forbidden on laser beam transmitters. Keep this device our of children’s reach and prevent its use by any unauthorised person, including children.
- Pointing the laser beam into eyes or at other parts of the body is strictly forbidden. Pointing the laser beam at any highly reflective surfaces is not permitted. The beam may be reflected from such a surface and enter somebody’s eye. Do not view the beam using optical equipment, e.g. binoculars.
- Due to the device’s interference with electromagnetic transmissions and other equipment and devices, please do not use this device inside aircraft or in the vicinity of medical equipment. Do not use it in an environment with an explosive or flammable atmosphere.
- Do not point the laser beam at easily flammable materials and liquids.
Inserting batteries / Display / Buttons
INSERTING AND REPLACING BATTERIES
- Remove the battery compartment cover on the rear side of the device and insert the batteries so that their correct polarity is maintained. Then close the battery compartment cover.
- Only type AAA batteries with a supply voltage of 1.5 V may be used in this device.
- When not using the device for an extended period of time, remove the batteries to prevent corrosion.
DISPLAY
BUTTONS
Turning on / turning off / setting a reference point
TURNING THE DEVICE ON AND OFF
- In the off mode, press button . The device and laser will turn on simultaneously and will be ready for measurement.
- In the on mode, hold down button for 3 seconds to turn off the device. The device will automati-cally turn off after 150 seconds of inactivity.
SETTING UNITS
Press button to reset the current units. Default value: 0.000 m
There are 6 types of units available.
Length | Area | Volume |
---|---|---|
0.000 m | 0.000 m2 | 0.000 m3 |
0.00 m | 0.00 m2 | 0.00 m3 |
0.0 in | 0.00 ft2 | 0.00 ft3 |
0.00 ft | 0.00 ft2 | 0.00 ft3 |
0 1/16 in | 0.00 ft2 | 0.00 ft3 |
0′ 00″ 1/16 | 0.00 ft2 | 0.00 ft3 |
SETTING A REFERENCE POINT
Press button to set the position of the reference point, i.e. define whether
the measured length will include the length of the device or not. Including
the length of the device when measuring distance has significance when
measuring the distance between two walls. The default reference point of this
device is the rear point.
Measurement modes
Note: To increase the measurement range in daylight or when the surface has poor reflective qualities, use the reflective target plate or white paper.
SINGLE LENGTH MEASUREMENT
Turn on the laser beam by pressing button in the measurement mode. Press
button again to measure a single length. The result is displayed on the main
row of the display.
CONTINUOUS MEASUREMENT
Hold down button in the measuring mode to enter the continuous measurement
mode. In this mode, the device continuously measures distance, whilst, in
addition to the currently measured value on the main row of the display, it
also displays the min./max. on the other rows. If you wish to leave the
continuous measurement mode, press button .
MEASURING AREA
Press button and symbol will appear on the display. One side of the rectangle will flash on the display. When measuring area, proceed according to the instructions below:
- Press button once to measure the length of one side and then press button again to measure the second side.
- The device calculates and displays the results on the main row of the display.
- The current length measurement is shown on the auxiliary row of the display.
- It is necessary to press button to delete the result and to start a new measurement.
- Press button to exit this mode.
MEASURING VOLUME
Press button twice and symbol will be shown at the top of the display. One
edge of the cube will flash on the display. When measuring volume, please
proceed according to the instructions below: Press button once to measure
length. Press button again to measure width. Press button for a third time to
measure height.
The device calculates and displays the results on the main row of the display.
It is necessary to press button to delete the result and to start a new
measurement. Press button to exit this mode.
PYTHAGOREAN THEOREM
The Pythagorean theorem function serves to calculate unmeasurable dimensions
from measured dimensions using a mathematical algorithm in the examples
provided below. On the images of each of the sub-functions the measured and
calculated sides are displayed. To achieve accurate measurements and
calculations, it is recommended to mount the device on a tripod.
Press button to select a mode.
-
Press button , the hypotenuse on symbol will flash. The device will calculate the second cathetus by measuring the hypotenuse and the other cathetus. Press button , measure the length of the hypotenuse (a) according to the flashing on the display. Press button , measure the length of one cathetus (b).
The device will calculate the other cathetus (x). -
Press button when one cathetus of symbol is flashing. The device will calculate the hypotenuse from the measurement of two catheti. Press button , measure the length of one cathetus (a). Press button , measure the length of the second cathetus(b).
-
The device will calculate the length of the hypotenuse (x).
-
Press button until the hypotenuse is flashing on the symbol on the display. Press button , measure the length of one hypotenuse (a). Press button , measure the length of the other hypotenuse (b). Press button , measure the length of one cathetus (c). The device will calculate the cathetus length of the full line (x).
-
Press button until one side of the hypotenuse is flashing on the symbol on the display. Press button , measure the length of one side (a). Press button , measure the length of the middle line (b). Press button , measure the length of the other side (c). The device will calculate the cathetus length of the full line (x).
The catheti must be shorter than the hypotenuse. Otherwise, “err” will appear on the display. To ensure accuracy, make sure that all the measure-ments are made from the same point.
ADDITION/SUBTRACTION
In the single length measurement mode, this device can be used to add or
subtract lengths.
Press button , the “+” symbol will appear on the main row of the display,
meaning that you are entering the addition mode.
The display will show the value of the last measure-ment and the resulting
sum.
Press button , the “-” symbol will appear on the main row of the display,
meaning that you are entering the subtraction mode.
The display will show the value of the last measure-ment and the subtraction
result.
Saving and viewing
The Save function can be used in the single length measurement mode.
SAVING MEASUREMENT RESULTS
Press button for 3 seconds, the result will automatically be saved to the
internal memory of the device.
VIEWING MEASUREMENT RESULTS
Press button to view the saved data. Use button or to scroll forwards and
backward. Holding down button will delete old entries.
ATTENTION
The spirit level on the device is only for indicative
(rough) measurement and any measurement inaccuracy or reduced functionality of
the spirit level is not grounds for complaint. For accurate measurement, use a
standard spirit level.
Error signals on the display
Some of the warning messages listed below may appear on the display:
Message | Cause | Solution |
---|---|---|
Err1 | Signal is too weak. | Select a more reflective surface. |
Use white paper or the reflective target plate.
Err2| Signal is too strong.| Select a less reflective surface. Use darker
paper.
Err3| Weak battery.| Replace the batteries.
Err4| The operating temperature is too high, outside the operating range.|
Wait for the device to cool down. Use the device in the prescribed temperature
range.
Err5| Error in the Pythagorean measurement mode.| Take a new measurement,
making sure that the hypotenuse is longer than the catheti.
Err6| The memory of the device is damaged.| Contact an authorised service
center.
Calibration
- Press and hold down the button and then simultaneously press the button.
- Use button or to set the correction value in the range -9 mm to +9 mm.
- Save the set value by pressing the button.
Maintaining and storing the device
- Please keep the surface of the device clean.
- To remove any dirt or dust, use a damp soft cloth.
- For maintenance and cleaning of this device, never use abrasive cleaning products or organic solvents (e.g. acetone).
- Perform maintenance around the lens and the lens itself using gentle products so that the lens is not scratched, e.g. first with a small brush or an air current to remove mechanical particles and then with, for example, a damp textile sold for cleaning eye glasses.
- Store the cleaned device in the supplied storage case in a dry location out of children’s reach, in the specified temperature range.
- Protect the device against radiant heat sources and direct sunlight.
Label and pictograms on the label
Waste disposal
PACKAGING MATERIALS
- Throw packaging materials into a container for the respective sorted waste.
ELECTRICAL EQUIPMENT
- Do not dispose of unserviceable commodities in household waste, but dispose of them in an environmentally safe manner. According to Directive 2012/19 EU, electrical appliances must not be thrown out with household waste, but rather handed over for ecological disposal at an electrical equipment collection point. The batteries must be removed from the electrical equipment prior to its disposal (if it contains them). You can find information about electrical equipment collection points and collection conditions at your local town council office.
FLAT BATTERIES
- An unusable batteries in the electrical equipment must be taken out of the electrical equipment prior to disposal and must not be, pursuant to Directive 2006/66 ES, thrown out with communal waste or into the environment, but rather must be handed over for ecological disposal/recycling at a determined battery collection point.
Warranty and service
- For warranty repairs of the product, please contact the vendor from whom you purchased the product and they will organise repairs/replacement at an authorised service centre for the Extol® brand. For a post warranty repair, please contact the authorised service centre of the Extol® brand directly (you will find the repair locations at the website at the start of this user’s manual).
- The product is covered by a 2-year guarantee from the date of sale according to law. If requested by the buyer, the seller is obliged to provide the buyer with the warranty conditions (rights relating to faulty performance) in written form.
- Free warranty repairs relate only to manufacturing defects on the product (hidden and external) and do not relate to the wear of the product as a result of excessive load or normal use or damage of the product caused by incorrect use.
- In the event of a dispute between the buyer and the vendor in respect to the purchase contract that was not resolved directly between the parties, the buyer has the right to the trade inspection authority for an out-of-court settlement of the a consumer dispute. At the website of the trade inspection authority there is a link to the tab “ADR-amicable dispute resolution”.