BISSELL Pet Hair Eraser Slim Cordless Vacuum Brush/Foot Area Instruction Manual
- June 7, 2024
- Bissell
Table of Contents
BISSELL Pet Hair Eraser Slim Cordless Vacuum Brush/Foot Area Instruction Manual
Pet Hair Eraser Slim Cordless Vacuum Brush/Foot Area | Support
If you’re experiencing issues in the Brush/Foot area follow these steps to resolve:
• Turn OFF > Remove the Foot Assembly
o Press the release button at the bottom of the Extension Wand
• Remove Access Plate by turning the 2 Screws
o Unhook the Brush from the Belt and lift Brush out > Remove all debris from
Brush and Brush End Caps
• For all 2900’s:
o Remove the Rotating Side Brushes
o There is only 1 Screw to remove the Access Plate
• Unhook the Brush from the Belt and lift Brush out > Remove all debris from
Brush and Brush End Cap
• Stand Brush upright > Hold the top and spin
o Is should spin freely, if not > Replace Brush > Go to Parts & Supplies
• Clear all debris from the Suction Channel
o You should be able to see through the opening (where the Extension Wand
attaches) into the Brush area
• If not, clear Channel of all debris
• Inspect Belt, Brush and Brush Access Plate for damage
o If damaged > Replace the damaged part (If Belt is damaged the Foot Assembly
will need to be replaced) > Go to Parts & Supplies
• Reattach Brush into Belt > Guide Brush into place
• Reattach Brush Access Plate > Secure 2 Screws
• Reconnect Foot to Extension Wand then to Hand Vac
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>