Polaris Fireplace
Installation manual
FKE-0892 Polaris Modern Fireplaces
WARNING: This manual only applies to the installation and operation of
dedicated burner in Polaris firebox only.
The product is a decorative device with real fire.
Read the included documentation prior to installing and operating the device.
Check the local regulations for fireplaces.
- For indoor use and in housing only. Min. temperature of use is 10°C.
- Room cubature for one device – min. 35 m³.
- Natural air exchange rate in room – min. 1/h.
- Do not use the device in humid and drafty spaces.
- Do not cover top ventilation openings of the device.
- Do not place any objects on the top of the device.
- We recommend placing a CO2 or dry powder fire extinguisher nearby the device
- For service purposes, the surrounding must allow for easy removal of the device.
- Keep children, animals and unauthorized persons away from the device.
- Keep the packaging and manuals for future use.
- Do not turn on the device in case of fuel spill.
- Do not interfere in the fuel filler when the device is operating.
- Do not interfere in the device construction.
- Do not touch the filament and other hot elements.
- Do not transport the device if fueled.
- Do not leave an operating device unattended
A. | Fireplace housing | Quantity |
---|---|---|
B. | Fuel container | 1 |
C. | Front glass | 1 |
D. | Service cable | 1 |
E. | Bag with granules | 1 |
F. | Bag with granules | 1 |
G. | Side glass | 1 |
H. | Power cable | 2 |
I. | Remote control | 1 |
J. | Mounting bracket | 1 |
K. | Mounting screws | 1 |
Plug the cables into the sockets at the bottom of the fireplace. Pull the cable with the plug through the opening at the back of the appliance.
Place the fuel container in place and screw on the cap with the fuel hoses.
Install the bracket J1 to the wall and J2 to the back wall of the fireplace using added bolts. Lift the fireplace and place it on the wall bracket. Attention! The fireplace must stand on legs and not hang.
Close the door. Level the appliance by adjusting the appliance feet.
Place the granules (E, F) evenly in the marked area leaving no uncovered area.
Use one bag (F) to cover the burner. Distribute the remaining bag (E) around
the ventilation mesh. Make sure the granules are not in contact with the
filament. Do not place the granules on the (VENTILATION MESH)
NOTE! Make sure the device is turned off and the glass shields have
cooled down to room temperature. Place the shield so the top edge fits in the
top frame space, then place its bottom edge in the bottom frame space. Lower
the glass shield vertically down. Proceed with the remaining glass shields.
Warning! hot air outlet, do not place any objects on the ventilation grid of the fireplace.
- Filament
- Burner
- Device surface
- Control panel
- Cap with a pumping hose 6. Fuel container
- ECO mode
- Flame ignition / flame extinguishing
- Service socket
- Control diodes
| Diodes OF
---|---
Diodes ON
Blinking diodes
REPLACING FUEL CONTAINER
- If the fuel container is empty ( ), unscrew the cap with the pumping hose and remove the container from the holder ( ) (I).
- Insert a full fuel container with a cap removed ( ) (II).
- Screw the cap with the pumping hose back on (III).
FLAME IGNITION
The green diode ( ) indicates that the device is ready to ignite the flame.
Press and hold START for 3 seconds. Flame ignition will take 2-10 minutes ( ).
The smell of ethanol vapours can be present during the ignition. The diode
READY off ( ) indicates that the flame has been ignited and the device reached
the working temperature.
FLAME HEIGHT REGULATION
After 3 min, press ECO to lower the flame (two sound signals). Press ECO again
to increase the flame height (one sound signal).
ATTENTION! In case the device temperature is too high, the flame will be
automatically lowered (ECO) and the height regulation blocked. If the
temperature keeps increasing, the device will be turned off.
FLAME EXTINGUISHING
Press STOP to extinguish the flame (sound signal + ).
You can ignite the flame again when the device is cooled – the green diode
READY ( ).
FAST START
The FAST START offers faster flame ignition (when the device is ready ( ), the
power consumption is 60 W higher).
The function is enabled by default.
To disable FAST START, press and hold ECO for 10 seconds (four sound signals).
To enable the function, press and hold ECO for 10 seconds (two sound signals).
TROUBLESHOOTING
Some alarms are accompanied by a sound signal. Press START/STOP to mute.
Lp.| DIODES| SOLUTION (contact the Service Department if the
solution does not eliminate the error)
---|---|---
1.| | The device is being cooled. Wait for the green diode .
2.| | The device run out of fuel while operating. The device is being cooled.
Wait for the red diode to turn off. Refill the tank.
3.| | An internal fuel spill occurred. Disconnect the pump. Wipe the visible
liquid and wait for min. 1 hour. Press and hold ECO on the control panel
for 10 seconds. If the error is not eliminated, wait for min. 24 hours.
If the error occurred during flame ignition, it means that the ignition time
has been exceeded. Press and hold ECO on the control panel for 10 seconds.
4.| | Device error. Press and hold ECO on the control panel for 10
seconds.
5.| | Tank overfilled. Contact the Service Department.
6.| | Room temperature too low (<10°C) or device error. Increase the room
temperature.
Press and hold ECO on the control panel for 10 seconds. Wait for the green
diode .
7.| | Device overheat. Please contact service department.
FUEL – Use only ethanol fuel produced from plants in the process of two-
time alcohol distillation consisting of 9596.6% ethanol by volume. Fanola is
the recommended fuel with pharmacological purity.
DO NOT USE SYNTHETIC PETROLEUM BASED FUELS AS THEY ARE CONTAMINATED, EMIT
UNPLEASANT ODORS AND CAN DAMAGE THE FIREPLACE! DO NOT USE FUELS CONTAINING
100% ETHANOL BY VOLUME, GEL, OR AROMATIC FUELS!
CLEANING – Clean with a damp cloth and delicate detergents, only when the
device is turned off and cooled.
SERVICE – Keep the provided USB cable for service. Reach out to us at
service@planikafires.com.