AEL 247CL LED Full Cutoff
LED Fixture with CNV Option
The LED fixture with CNV option is a versatile lighting solution that can easily convert from a lens fixture to a full cutoff (FCO) fixture in the field. The product is designed to provide efficient and long-lasting illumination for indoor and outdoor spaces.
Important Safety Instructions
- Read and follow all safety instructions.
- Disconnect or turn off the power before installation or servicing.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
- Allow lamp/fixture to cool before handling. Do not touch the enclosure or light source.
- Keep combustible and other materials that can burn, away from lamp/lens.
- Never connect components under load. Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
Product Usage Instructions
To convert the 247L fixture with CNV option from a lens fixture to a full cutoff (FCO) fixture, follow the below steps:
Tools and Materials Required
- 5/16 nut driver or slotted screwdriver (to open fixture)
- Philips head screwdriver
Procedure
- Disconnect or turn off the power before starting the installation process.
- Open the fixture by unscrewing the latch screw (or using the trigger latch, if applicable) and swinging the lid open.
- To remove the wireway, slide the top of the wireway to the right and then lift the metal wireway up while taking it out from around the wire harness. Ensure that the wire harness remains in place. Keep the metal wireway as it will be reinstalled later.
- Remove the lens by unscrewing the retaining screws and carefully lifting it from the fixture.
- Install the FCO assembly by placing it into the fixture and securing it with the retaining screws.
- Reinstall the wireway by sliding it back into place over the wire harness.
- Close the fixture by swinging the lid back into place and securing it with the latch screw (or trigger latch).
- Turn on the power and test the fixture to ensure it functions properly.
Always follow the manufacturer’s warnings, recommendations and restrictions for driver type, burning position, mounting locations/methods, replacement and recycling. Failure to follow any of these instructions could void product warranties. For additional warnings or any applicable FCC or other regulatory statements, refer to the product-specific installation instructions.
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance on this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by a person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- It will occasionally be necessary to clean the outside of the refractor/lens. The frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to the user. The refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should the optical assembly become dirty on the inside, wipe the refractor/lens and clean in the above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCTS! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that the supply voltage is correct by comparing it with the luminaire label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL-approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing luminaire from cartons, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch the enclosure or light source.
- Do not exceed the maximum wattage marked on the luminaire label.
- Follow all manufacturer’s warnings, recommendations, and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from the lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
LED IMPORTANT SAFETY INSTRUCTIONS
CAUTION: RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer pack, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around the fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed the fixture’s maximum ambient temperature.
- Only use the fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event, your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixture’s complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product-specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Our Brands
Indoor/Outdoor
- Lithonia Lighting
- Carandini
- Holophane
- RELOC
Indoor Lighting
- Gotham
- Mark Architectural Lighting
- Peerless
- Renaissance Lighting
- Winona Lighting
Outdoor Lighting
- American Electric Lighting
- Antique Street Lamps
- Hydrel
- Tersen
Controls
- DARK TO LIGHT
- Lighting Control & Design
- ROAM
- Sensor Switch
- Synergy
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products. ABL LED General Warnings, Form No. 503.203 © 2013 Acuity Brands Lighting, Inc. All rights reserved. 6/12/13
INTRODUCTION
Product Description
The 247L fixture with CNV option can be easily converted from a lens fixture
to a full cutoff (FCO) fixture in the field with a few quick steps.
INSTALLATION
Tools and Materials Required
5/16” nut driver or slotted screwdriver (to open fixture) Philips head
screwdriver
Procedure
- Open the fixture by unscrewing the latch screw (or using the trigger latch, if applicable) and swinging the lid open.
- Locate the screw at the top of the wireway as shown in Figure 2. Loosen the screw by turning it counterclockwise for 2-3 full rotations. It is NOT required to completely remove the screw.
- To remove the wireway, slide the top of the wireway to the right and then lift the metal wireway up while taking it out from around the wire harness. Ensure that the wire harness remains in place. Keep the metal wireway as it will be reinstalled later.
- Remove the 4 lens panels by lifting them out of the fixture.
- Re-install the wireway by first inserting the bottom of the wireway into the hole closest to the edge of the housing.
- Slide the wire harness back into the wireway and then re-secure the wireway by sliding the lower slot in between the screw and the housing. Rotate the screw clockwise until it is hand-tight.
- Close the lid and tighten the latch screw (or trigger latch, if applicable).
Contractor Resources
Check out helpful programs, tools, installation videos, and more!
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Fabricantes de alumbrado publico e iluminación inteligente - CARANDINI
- U.S. Environmental Protection Agency | US EPA
- U.S. Environmental Protection Agency | US EPA
- Holophane | Lighting solutions for commercial, industrial, emergency and outdoor applications.
- Lithonia Lighting® | Best Value in Lighting