BEOK TGW60 Glass Screen Thermostat Instruction Manual
- June 3, 2024
- BEOK
Table of Contents
- BEOK TGW60 Glass Screen Thermostat
- Product Summary
- Technical Parameter
- Main Functions and Characteristics
- User Interface Explanation
- Model Definition
- Model Spec
- Wiring Digram
- Thermostat Operation Instruction
- Installation Instruction
- In the box you will find
- Our Service
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEOK TGW60 Glass Screen Thermostat
Product Summary
TGW60 series thermostats are luxurious programmable thermostat with large screen display.It is applied to temperature control of industrial, commercial and domestic room,and start of control heating applicance, especially used in the floor-heating systems.
Technical Parameter
Power Supply | 100 ~ 240V |
---|---|
Current Load | ≤3A(water heating/gas boiler) |
≤16A(electric heating)
Power Consumption| <1W
External Material| PC+ABS (flame retardant)
Sensing Element| NTC
Set Temp. Range| 5-95℃
Floor Set Temp. Range| 5-60℃
Accuracy| ±1℃
Dimension| 86x90x14mm
Ambient Temp.| 0-45℃,5-95%RH(Non-condensing)
Storage Temp.| -5~55℃
Timing Error| <1%
Main Functions and Characteristics
- Model design same as a cell phone
- Large screen display and touch button
- Power-off memory function
- Real-time data save function
- 5+2 or 6+1or 7days six periods program schedule
- Anti-freezing function
- 3 sensor modes can be setting
- Selectable 80mmx80mm European hidden box.
- With child lock function
User Interface Explanation
Model Definition
- EP: For Electric Floor Heating System, 16A
- WP: For Water Floor Heating System, 3A
- WPB: For Gas Boiler Heating System, 3A
- For example: TGW60-EP TGW60-WP TGW60-WPB
Model Spec
| Current Week
Loading Program
|
Controlled Objects
---|---|---
TGW60-EP
|
16A
|
For electric heating appliances
TGW60-WP
| 3A|
For water heating appliances
TGW60-WPB
|
3A
|
For gas boiler
Wiring Digram
Thermostat Operation Instruction
-
Setting Power on/off
Press to turn on/off the power. -
Setting Temperature
Press to set the temperature. -
Setting the Clock
Long press M and to set minute, hour and week.
Press for adjusting. -
Setting the Manual Mode.
Manual mode means non-programmable mode.
Press M then will display in the s creen, it is in manual mode.
Press to set the temperature. -
Setting the Child Lock
Long press to enter into child lock mode, will display. -
Long press again, the child lock will be disappeared.
-
Setting the Programmable Mode.
Press and hold M into programmable mode. 12345 and time will display. 12345 display in the position of week means 5+2;
Press to change the time.
Press M to do the temperature adjustment.
Press to change the temperature;
Press M to do the next period adjustment.
Press to exit and save.
If you want to make temporary adjustment in any period,
press or when will display. When finish the setting, all will confirm
automatically.
Press M to switch operation between manual mode and programmable mode.
Period | Period Icon | Defaulted Time | Defaulted Temp. |
---|
Week
| 1| | 6:00| 20℃
2| | 8:00| 16℃
3| | 11:30| 16℃
4| | 12:30| 16℃
5| | 17:30| 22℃
6| | 22:00| 16℃
Weekend
| 1| | 8:00| 22℃
2| | 23:00| 16℃
Remark:
The defaulted temperature of period3 and period4 is the same as period2.
Please change it according to the request.
Advanced Setting
- In the state of power-off, press the M key and the key for 5 seconds to enter the advanced option setting.
- Press M to e nter the next option, press and to adjust, and press to exit.
Display Code | Function | Setting And Options | Factory Defult |
---|---|---|---|
1ADJ | Temp. compensation | -9.9-9.9℃ | -2℃ |
2SEN
|
Sensor selection
| IN: Internal sensor OUT: Floor sensor
ALL: Both internal sensor and floor sensor
|
IN
3LIT| Modify the temp. limit| 5-60℃| 35℃
4DIF| Temp. difference start| 0.5-10℃| 1℃
5LTP| Antifreeze function| OFF:Close anti-frozen
ON:Open anti-frozen
| OFF
6PrG
| Weekly programming mode| 0: 7 days programmable
1: 6+1 programmable
2: 5+2 programmable
|
2
7rLE| Primary and secondary reverse selection| 00: close the main and
auxiliary reversal 02: auxiliary reversal
| 00
8dLy| Passive linkage
output delay time
| 0-5min| 0
9HlT| Set upper temp. limit| 35-95℃| 60
RFAC
| Restore factory defaults| long press up button to adjust the display “—”, press power button to restore the factory settings|
–
Sensor error:
Please select the right sensor mode. If select the different mode or there is
error of sensor, Err will display on the LCD screen, the thermostat will stop
heating till the problem is solved.
Installation Instruction
This product is suitable for standard 80*80mm wall box and 60 mm european round box.
- Connect the power box according to the wiring diagram.
- Separate the power supply from the control board cable.
- Screw the power supply into the box of 86.
- Connect the power board to the board line, and align the buckle at 30 degrees to complete the installation.
ATT:
Thank you for buying this product!
Please read this manual for complete instructions on installing and operating
your thermostat. If you require further assistance, please feel free to
contact us.
In the box you will find
Model | TGW60-EP | TGW60-WP | TGW60-WPB |
---|---|---|---|
Thermostat | √ | √ | √ |
User Manual | √ | √ | √ |
Screws | √ | √ | **** |
√
External sensor| √| |
Our Service
We offer the warranty of 24 months from the sales day.
During the warranty, if it is belong to the quality issue, we will fix or
replace them for you by free after test them.
If it is not quality problem or beyond the warranty time, we will charge for
the after-sales service.
warning
The symbol means the unit is being installed, it may cause electrical shock hazard during maintaining, so please make sure it is operated by the professional technical worker.