TE connectivity VR3/ER3 Two Stage General Purpose RFI Power Line Filter User Guide

June 4, 2024
TE connectivity

Corcom Product Gide

Two Stage General Purpose RFI Power Line Filter

R Series

  • Dual T section RFI filter provides premium performance
  • Well suited for low impedance loads where noisy RFI environments are present
  • Controls pulsed, continuous and/or intermittent interference
  • ER models offer low leakage current without deterioration of insertion loss

Ordering Information

*IEC 60320-1 C14 inlet mates with C13 connector

Specifications

Maximum leakage current for each Line to Ground:

| VR Models| ER Models
---|---|---
@ 120 VAC 60 Hz:| .4 mA| .21 mA
@ 250 VAC 50 Hz:| .7 mA| .36 mA

Hipot rating (one minute):

The line to Ground: 2250 VDC
Line to Line: 1450 VDC

Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 1 to 20A
Operating Ambient Temperature Range
(at rated current Ir): -10°C to +40°C
In an ambient temperature (Ta) higher than +40°C the maximum operating current (1₀) is calculated as follows: l₀ = Ir

Available Part Numbers

1VR1 1ER1
1VR3 1ER3
2VR1 2ER1
2VR3 2ER3
3VR1 3ER1
3VR3 3ER3
3VR7 3ER7
3VR7M 3ER7M
5VR1 5ER1
5VR3 5ER3
5VR7 5ER7
5VR7M 5ER7M
10VR1 10ER1
10VR3 10ER3
10VR6 10ER7
10VR7 10ER7M
10VR7M 20ER1
20VR1
20VR6

Electrical Schematic

Case Styles
R1 (1, 2, 3, 5, 10A)

Typical Dimensions:
Line/Load Terminals (4): .250 [6.3] with .07 [1.8] Dia. hole
Ground Terminal (1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
Mounting Holes (2): .188 [4.78] Dia.

R1 (20A)

Typical Dimensions:
Line/Load Terminals (4): .250 [6.3] with .07 [1.8] Dia. hole
Ground Terminal (1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
Mounting Slots (4): .250 x .156 [6.35 x 3.96] Dia.

R3

Typical Dimensions:
Wire Leads (5): 4.0 [101.6] Min., AWG18
Mounting Holes (2): .188 [4.78] Dia.

10VR6

Typical Dimensions:
Terminals (5): 8-32, Torque 18 lbf-in. [2.03 N-m] max. ± 2 [.22] Mounting Holes (2):.188 [4.78] Dia.

20VR6

Typical Dimensions:
Terminals (5): 8-32, Torque 18 Ibf-in. [2.03 N-m] max. ± 2 [.22] Mounting Slots (4):.250 x .156 [6.35 x 3.96] Dia.

R7 & R7M

Typical Dimensions:
Load Terminals (2): .250 [6.3] with .07 [1.8] Dia. hole
Ground Terminal (1): .250 [6.3] with .07 x .16 [1.8 x 3.8] slot
Line Inlet (1): IEC 60320-1 C14
K7 Tapped Inserts (2): 6-32 x 1/4
K7M Tapped Inserts (2): M3 x .5

Recommended Panel Cutout

Tolerance ± .005[0.13]

Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord

Case Dimensions

Performance Data

Typical Insertion Loss
Measured in a closed 50 Ohm system

Minimum Insertion Loss

Measured in a closed 50 Ohm system
Common Mode / Asymmetrical (Line to Ground)

Current Rating|

Frequency – MHz

---|---
.15| .5| 1| 5| 10| 30
VR Models
1A, 3A| 30| 65| 65| 65| 65| 65
2A, 5A, 10A, 20A| 5| 44| 60| 65| 65| 60
ER Models
1A, 3A| 25| 60| 65| 65| 65| 65
2A, 5A, 10A, 20A| 2| 35| 51| 63| 60| 50

Differential Mode / Symmetrical (Line to Line)

Current Rating Frequency – MHz
.15 .5

VR Models
1A, 3A| –| –| 65| 60| 54| 46
2A, 5A, 10A, 20A| –| –| 35| 60| 57| 45
ER Models
1A, 3A| –| –| 65| 60| 54| 46
2A, 5A, 10A, 20A| 2-| –| 35| 60| 57| 45

Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications are subject to change.

UL Recognized
CSA Certified
VDE Approved
For email, phone, or live chat, please go to
te.com/help
corcom.com
Catalog: 1654001
Issue Date: 06.2011

Read User Manual Online (PDF format)