TE connectivity PE0S0SS6B P Series Versatile Power Entry Module with Small Footprint Instruction Manual
- June 4, 2024
- TE connectivity
Table of Contents
TE connectivity PE0S0SS6B P Series Versatile Power Entry Module with
Small Footprint
P Series
The P series CHAMELEON power entry module offers the most popular features in
a small footprint design
As the first l0A module to provide all five power entry functions in one
compact design, the chameleon module readily adapts to its environment and the
needs of international markets.
- Snap-in or flange mounting
- Standard IEC 60321-1 Cl4 power inlet
- Both North American and metric fusing capabilities
- Two voltage selection options (for 4-voltage selection, see the M, L or LA Series)
- Optional DPST on/off switch
- Filter options for general purpose, medical and high-performance EMI filtering
The CHAMELEON module’s compact design and modular construction allows selection of the required power entry feature – without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts.
Filter Types
The CHAMELEON module has four filter and one non-filtered option:
S models provide an extended performance two element circuit EMI filter, with
attenuation similar to the EEB Series power inlet filter. It offers protection
for general purpose applications with stray Line to Ground and Line to Line
noise that must be attenuated at the power inlet. These filters have limited
leakage current and are available in current ratings of 3, 6 and lOA.
H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment.
L models feature a high performance medical filter designed to help bring
most digital equipment
(including switching power supplies) into compliance with EN55022, Level B (as
well as FCC part 15J, Class B) conducted emissions limits. They are available
with current ratings of 6 and l0A. These high performance versions are only
available with mounting ears, single voltage selection, in a complete RFI
shield with options for switch, fuses and current ratings. Mounting extenders
are not compatible with the L or Z models.
Z models provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series
B models are non-filtered and incorporate an interconnection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options.
Ordering Information
Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as “O” use the digit ZERO (0) not the letter (0).
Extender
Option
- 0 = None
- C = FN260
- J = J Series
- L = L Series’
Input Voltage Select
- 0 = Single voltage
- S = Dual voltage2 select (SMPS)
- X = Dual voltage2 select (series/parallel)
Filter Type
- 0 = No filter
- B = Interconnection block3
- H = Medical Filter
- L = High Performance C Medical4
- S = General purpose
- Z = High Performance4
Shield Options
- 0 = No shield
- A = Filter shield
- B = Complete Shield
- C = Complete can (for L & Z models)
Notes:
- L Series extender cannot be added to units with a shield. No style of extender can be added to units with B or C shields.
- Dual voltage options are not available with L or Z Filter Types
- When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B)
- High performance versions (Lor Z filter types) are available with any switch or fuse option but only in 6 or lOA with horizontal (PE) or vertical (PM) mounting ears, single voltage (0),complete shield (C) and no extenders For alternative switch orientation options, contact technical support or your Corcom product sales representative.
The part number PS0SXSS6B would represent:
P Series (P) with a snap-in mount (S) with no extender (0) a switch (S)
dual voltage select (X) single fusing (S) general purpose filter (S) for 6A
(6) with a B shield (B).
Voltage Selection
P series power entry modules include the voltage selector integral with the
fuse holder. Three voltage selection options are each supported by one of
three different fuse holders. The fifth digit of the part number specifies
which of the three fuse holders is included to provide the desired voltage
selection. The single voltage fuse holder (option “0”) has no voltage
indication markings. The dual voltage options select 115V or 230V by removing
the fuse holder, flipping it over, and reinstalling it. Voltage selection is
indicated through a window in the P Series door. The “SMPS” fuse holder
(option “S”) jumpers two independent P Series terminals to indicate 230V
operation to a switching mode power supply. The
“PRSR” parallel/serial fuse holder (option “X”) connects the windings of the
equipment’s dual primary transformer (not included) to step down the voltage
or double up the current. The markings on the voltage selection fuse holders
also remind the user to install the appropriate fuse for the current at the
selected voltage.
Input Voltage Selection Schemes
S – “SPMS” Jumper Type **X – “PRSR” Parallel / Serial
Type for
Dual Primary Transformer Note 1: Additional jumper wiring
is required if a filter or interconnection module is not used.
Note 2:** Location of optional filter. Additional jumper wiring is required if
a filter or interconnection block is not used.
Shield Options
The P series offers several RF shield options. The metal shield, optional on
S, H and B filtered models, provides shielding from radiated emissions and
provides an RF ground for the filter to the panel. This shield is available in
two versions; a shield of the filter components (designated by an A as the
final digit) and a complete shield (designated by B as the final digit).
The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender.
The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender.
A complete metal enclosure is integral to both the high performance L and Z models, and must be specified by a C in the part number’s final digit. This option is only available with the L or Z models.
Fuse holder
Another feature of the P series power entry module is the versatile fusing
arrangement. The fuse holder can hold two 1/4″ x 1-1/4″ (3AG) or 5 x 20mm
(metric) fuses. Single fusing is supported with a conversion clip that shorts
one of the two fuse positions, and is designated by an S in the sixth part
number digit. A module designated for a single fuse may be reconfigured by
the manufacturer or the user to accept two fuses by simply removing the
shorting clip. For applications intended for dual fusing, specify a D in the
sixth part number digit.
Interconnection Block
Installation of the unfiltered versions of the P series requires wiring of the
IEC socket terminals to the optional switch and the switch to the fuse holder.
Labor can be eliminated by ordering the module with an interconnection block.
This feature, designated by “BX” in the seventh and eighth digits, pre wires
the module so that only connection to the equipment must be done during
installation. The interconnection block includes a plastic case to prevent
access to the internal connections.
The dimensions of this alternative are the same as the filtered versions.
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
PAlOO: Power interconnect assembly
For voltage select models. Designed for use with either filtered or non-
filtered units, 6″ wire leads
-
PA101: Plug only
-
PA102: Pins only for use with PA101
-
PA105: Same as PAl00 but with two wires for units with no voltage selection
-
PA400: J Extender
Extends P Series height to fit J panel cutout -
PA410: L Extender
Extends P Series width to fit L panel cutout -
PA420: C Extender
Extends P Series height to fit C panel cutout.
PA400
J Series Extender
- C & L Extenders can not be used with B Shields.
- L Extender can not be used with shields
Specifications
Maximum leakage current each Line to Ground:
Electrical Schematics
Case Styles
Front View
Typical Dimensions:
- Line Inlet (1):IEC 60320-1 C14
- Mounting holes (2): .13513.43] Dia. with .2315.9] Dia. x 82° countersink for #4 flathead screw (PM, PE only)
Extender Options
Standard Models – Side and Rear View Typical Dimensions:
- Terminals:. 187 [4.8] with .055 [1.4] Dia. hole. Recommended for use with mating connectors – no solder .
- Ground Terminal (1):187 [4.8] with .112 x .06 [2.8 x 1.5] slot. Recommended for use with mating connectors – no solder
High Performance Models – Side and Rear View
Typical Dimensions:
- Terminals: .250 [6.4] with .07 [1.8] Dia. hole. Recommended for use with mating connectors – no solder .
- Ground Terminal (1): 250 [6.4] with .16 x .07 [4.1 x 1.8] slot. Recommended for use with mating connectors – no solder
Shield Options
NOTE: Shields can only be used with filtered models. B shield may not be used with J or C extender
Recommended Panel Cutout
NOTE: For snap-in applications, the ”A” sides must have a .020 [508]
radius on the installation side.
Dimensions are for front mount applications. Rear mount dimensions should be
determined based on customer’s application parameters. Snap-in models allow
for front mounting only Not recommended for use in plastic panels.
*For panel thickness of 0.037 – 0.079 [0.787 – 2.07] only Use 2.273 [56.27] for panel thickness of 0.083 – 0.774 [2.0 – 2.90]
Performance Data
Typical Insertion Loss — Common Mode/ Asymmetrical (L-G)
Measured in closed 50 Ohm system — Differential Mode/ Symmetrical (L-L)
S Models
Minimum Insertion Loss
Measured in closed 50 Ohm system