TE connectivity VK6 K Series Corcom General Purpose RFI Power Line Filter User Guide
- June 4, 2024
- TE connectivity
Table of Contents
VK6 K Series Corcom General Purpose RFI Power Line Filter
User Guide
UL Recognized CSA Certified VDE Approved**
K Series
- Suitable for high-impedance loads
- Well suited to applications where pulsed, continuous, and/or intermittent RFI interference is present
- EK models meet the very low leakage current requirements for VDE portable equipment and non-patient care medical equipment
- Available with ground line inductor (choke)
Ordering Information
*1-75A: IEC 60320-1 C14 inlet mates with C13 connector
20VK7: C20 inlet mates with C79 connector
Specifications
Maximum leakage current each Line to Ground:
| VK Models| EK Models
---|---|---
@ 120 VAC 60 Hz:| .5 mA| .21 mA
@250 VAC 50 Hz:| 1.0 mA| .36 mA
Hipot rating (one minute):
The line to Ground: | 2250 VDC |
---|---|
Line to Line: | 1450 VDC |
Rated Voltage (max): | 250 VAC |
--- | --- |
Operating Frequency: | 50/60 Hz |
Rated Current: | 1 to 60A* |
Available Part Number
DIROZ | DIRZ | 2>IAOL |
---|---|---|
VIL>130L | 2>13L | LNAOL |
L>IROL | DIRL | klbiAS |
2>I3OL | 9>1A09 | blAS |
DI3OL | 09>IA017 | 2>IAS |
WEARS | 9>IA017 | LNAS |
L>199 | D9NA02 | IAJLAA2 |
2>119 | 9>IA02 | L.>IA2 |
DIDS | *DIAOZ | >1A2 |
WL>132 | 9>IAOZ | DIA2 |
L>I32 | DIAOZ | 2NAZ |
2>112 | lAIDIAOL | DIAZ |
LN12 | LAAOL | 2NAL |
2>ISZ | 9NAOL | DIAL |
**20VK7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 76A, 250VAC
Electrical Schematics
Accessories
GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord
Case Styles
Typical Dimensions:
( Line/Load Terminals (4): | ..250 [6.3] with .07 [1.8] Dia. hole |
---|---|
Ground Terminal (1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
Mounting Holes (2): | .188 [4.78] Dia. |
Typical Dimensions:
( Line/Load Terminals (4): | ..250 [6.3] with .07 [1.8] Dia. hole |
---|---|
Ground Terminal (1): | .250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
Mounting Holes (2): | .188 [4.78] Dia. |
Typical Dimensions:
Wire Leads (5): | 4.0 [101.6] Min., AWG18 (AWG16 for 10A) |
---|---|
Mounting Holes (2): | .188 [4.78] Dia. |
Typical Dimensions:
Terminals (5): | 8-32, Torque 18 Ibf-in. [2.03 N-m] max. ± 2 [.22] |
---|---|
Mounting Holes (2): | .188 [4.78] Dia. |
Typical Dimensions:
Terminals (5): | 8-32, Torque 18 Ibf-in. [2.03 N-m] max. ± 2 [.22] |
---|---|
Mounting Holes (2): | .188 [4.78] Dia. |
30 VK6/6C & 40VK6/6C
Typical
Dimensions:
Terminals (5): | B-32, Torque 18 Ibf-in. [2.03 N-m] max. ± 2 [.22] |
---|---|
Mounting Slots (4): | .250 x .156 [6.35 x 3.96] Dia. |
60VK6
Typical Dimensions:
Terminals (5): | B-32, Torque 18 Ibf-in. [2.03 N-m] max. ± 2 [.22] |
---|---|
Mounting Slots (4): | .250 x .156 [6.35 x 3.96] Dia. |
K7 & K7M ( 3.5.10A)
Typical Dimensions:
Load Terminals (2): | .250 [6.3] with .07 [1.8] Dia. hole |
---|---|
Ground Terminal (1): | 250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
Line Inlet (1): | IEC 60320-1 C14 |
K7 Tapped Inserts (2): | 6-32 x 1/4 |
K7M Tapped Inserts (2): | M3 x .5 |
20VK7
Typical Dimensions:
Load Terminals (2): | .250 [6.3] with .07 [1.8] Dia. hole |
---|---|
Ground Terminal (1): | 250 [6.3] with .07 x .16 [1.8 x 3.8] slot |
Line Inlet (1): | IEC 60320-1 C14 |
K7 Tapped Inserts (2): | 6-32 x 1/4 |
K7M Tapped Inserts (2): | M3 x .5 |
Case Dimensions
Part No.| A
(max)
| B
(max)
| C
(max)
| D
±.015
±38
| E
(max)
---|---|---|---|---|---
1VK1, 1EK1,
2VK1, 2EK1
| 3.1
78.7
| 2.07
52.6
| 0.91
23.1
| 2.375
60.33
| 2.81
74.1
1VK3, 1EK3,
2VK3, 2EK3
| 1.81
46.0
| 2.07
52.6
| 0.91
23.1
| 2.375
60.33
| 2.81
74.1
3VK1, 3EK1,
5VK1, 5EK1
| 3.10
78.7
| 2.07
52.6
| 1.16
29.5
| 2.375
60.33
| 2.81
74.1
3VK3, 3EK3,
5VK5, 5EK3
| 1.81
46.0
| 2.07
52.6
| 1.16
29.5
| 2.375
60.33
| 2.81
744
3V K7/7 M ,
3EK7/7M
| 3.21
81.5
| 2.25
57.2
| 1.28
32.5
| 1.575
40.01
| **0.63***
16.0*
5VK7/7M,
5EK7/7M
| 3.21
81.5
| 2.25
57.2
| 1.28
32.5
| 1.575
40.01
| **0.63***
16.0′
10VK1,
10EK1
| 3.35
85.1
| 2.07
52.6
| 1.16
29.5
| 2.375
60.33
| 2.81
71.4
10VK3,
10EK3
10VK6
| 2.07
52.6
3.46
87.9
| 2.07
52.6
2.07
52.6
| 1.16
29.5
1.16
29.5
| 2.375
60.33
2.375
60.33
| 2.81
71.4
2.81
71.4
_
10VK7/7M,
10EK7/7M
| 3.71
94.2
| 2.25
57.2
| 1.28
32.5
| 1.575
40.01
| **0.63***
16.0′
20V K1,
20EK1
20VK6
20VK7
| 3.35
85.1
3.46
87.9
3.8
90.4
| 2.56
65.0
2.56
65.0
2.28
54.6
| 1.53
38.9
1.53
3&9
1.78
39.6
| 2.938
7463
2.938
_ 74.63
1.575
74.63
| 3.35
85.1
3.35
_ 85.1
.846′
85.8′
30VK6,
30VK6C
| 5.34
135.6
| 3.38
85.9
| 1.53
38.9
| 3.75
95.25
| 4.20
106.7
40VK6,
40VK6C
| 134
135.6
| 3.38
85.9
| 1.53
38.9
| 3.75
95.25
| 4.20
106.7
60VK6| 6.0
152.4
| 3.38
85.9
| 1.53
38.9
| 3.75
95.25
| 4.20
106.7,
Recommended panel Cutouts
Performance Data
Typical Insertion Loss
Measured in closed 50 Ohm system
| Frequency – MHz
---|---
Current Rating| 0.15| 0.5| 1| 5| 10| 30
Vk Models|
1, A| 15| 30| 30| 50| 50| 50
2,A 5A, 10,A| 6| 19| 38| 42| 45| 50
20A| 6| 19| 28| 42| 45| 50
30A, 40A| 6| 19| 28| 42| 45| 50
60A| 6| 22| 28| 32| 39| 35
Ek Models|
1A,3A| 15| 29| 35| 45| 45| 50
2A,5A,10A| 8| 19| 25| 38| 40| 45
20A| 8| 19| 25| 38| 40| 45
| Frequency – MHz
---|---
Current Rating| 0.15| 0.5| 1| 5| 10| 30
Vk Models|
1A,3A| –| –| 48| 55| 50| 35
2,A 5A, 10,A| –| –| 30| 50| 30| 30
20A| 6| 6| 30| 50| 30| 30
30A, 40A| 2| 40| 60| 65| 57| 55
60A| 13| 49| 67| 57| 53| 53
Ek Models|
1A,3A| –| –| 48| 55| 50| 35
2,A 5A, 10,A| –| –| 30| 50| 30| 30
20A| 6| 6| 30| 50| 30| 30
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications are subject to change.
For email, phone or live chat, please go to
te.com/help
corcom.com