Technical Specifications

  • Product type High bay microwave motion sensor (Daylight harvest)
  • Operating voltage 120~277VAC 50/60Hz
  • Rated load Resistive:700W@120V; 1600W@220-277V;
  • Capacitive:400VA@120V; 800VA@220-277V;
  • Power consumption < 1W
  • Detection angle 360
  • Detection area (Max.)* Installation Height: 15m Detection Range (Ø):12m
  • Detection range 10% / 50% / 75% / 100%
  • Hold time 2s / 30s / 1min / 5min / 10min / 15min / 20min / 30min
  • Stand-by time 0s / 10s / 1min / 5min / 10min / 30min / 1h / +
  • Stand-by dimming level 10% / 20% / 30% / 50%
  • Daylight threshold 50 ~ 500Lux, Disable
  • Warming up time 20s
  • Operating temperature -20o C ~ +50o C
  • IP rating IP42

Installation

HYTRONIK-HMW12-Surface-Mount-High-Bay-Motion-Sensor-
FIG2

Warnings:

  1. Installation must be carried out by a qualified engineer in accordance with local regulations.
  2. Disconnect supply before installing.
  3. Install to a solid surface – vibrations may cause is-triggering.
  4. Ensure environmental conditions are suitable for electronic equipment

Note:We recommend the mounting distance between sensor to sensor should be more than 2m to prevent sensors from false-triggering.

Rotary Switch Settings

A rotary switch is built inside the sensor for scene selection / fast programming. Total 16 channels available:

HYTRONIK-HMW12-Surface-Mount-High-Bay-Motion-Sensor-
FIG4

Note: settings can also be changed by remote control HRC-11. The last action controls.

Direct junction “J” box mounting

  • Separate control board (A) from facia (B) & junction box (C).
  • Make electrical connections to control board (A). See detailed wiring diagram on next page.
  • Secure control board (A) to junction box.
  • Set-up sensor modes as per sections 3 & 4 of this manual.
  • Clip facial plate (B) to control board (A).

Surface mount assembly

  • Separate control board (A) from facia (B) & Surface box (C).
  • Securely mount surface box (C) to a flat and solid surface.
  • Make electrical connections to control board (A). See detailed wiring diagram on next page.
  • Set-up sensor modes as per sections 3 & 4 of this manual.
  • Secure control board (A) to the surface box (C).
  • Clip facial plate (B) to control board (A).

Daylight Harvest (Daylight Regulating)
Daylight sensor measures the available surrounding natural light, calculates how much electrical light is needed to reach the total lux expected. The demand is given to the LED driver by 1-10V signal, so as to deliver the needed amount of electric light.

HYTRONIK-HMW12-Surface-Mount-High-Bay-Motion-Sensor-
FIG7

Lux Off Function

The light dims to minimum level even switches off completelly if ambient daylight is sufficient (natural light level exceeds target lux level), no matter it is during hold-time or stand-by time, with or without motion.
Note: if the stand-by time is preset at “+∞”, the light never turns off even when natural light is sufficient.

Manual Override

With the help of a push-switch, this sensor may be over-ridden by the end- users to switch on/off the lights manually, or adjust the light brightness during motion hold-time. This makes the product more user-friendly and offers more options to fit for extra-ordinary demands.

  • Short push (<1s): on/off function;
    ON → OFF: the light turns off immediately and cannot be lighten for a certain time (equals to hold time preset) even there is movement is detected. After this period, the sensor goes back to auto sensor mode.
    OFF → ON: the light turns on 100% and goes to auto sensor mode, even when ambient Lux level exceeds the daylight threshold.
    * Long push ( >1s): adjust the target lux level by turning the light up or down. Both the adjustment on remote control and push switch can overwrite each other, the last adjustment remains in the memory.

Semi-auto Function (Absence Detection)

The motion sensor is employed, but only activated on the manual press of the push switch, The light remains on during presence and dims down in absence, eventually switching off automatically after the stand-by time has expired.
Note: in this mode, the push terminal used for the ‘manual on’ switch input. End-user can choose either function 4.3 or 4.4 for the application. Default function is 4.3.

Wiring Diagram

HYTRONIK-HMW12-Surface-Mount-High-Bay-Motion-Sensor-
FIG8

Note: if neither function 4.3 nor 4.4 is desired, simply leave the “push” terminal disconnected.

Detection Pattern

Description of the Button Functions

(remote control HRC-11)

HYTRONIK-HMW12-Surface-Mount-High-Bay-Motion-Sensor-
FIG10

Permanent ON/OFF [1]

Press button 1 to select permanent ON or permanent OFF mode. * Press the button 2/4 to resume automatic operation. The mode will change to AUTO Mode after power failure.

RESET [ button 2]
Press button 2, and all settings go back to the rotary switch settings.

Shift [ button 3]

Press button 3, and the LED on the top left corner is on for indication. All values/settings in RED are in valid for 20 seconds.

Auto Mode [ button 4]

Press button 4 to initiate automatic mode. The sensor starts working and all settings remain as before the light was switched ON/OFF.

Semi-auto Mode [buttons 3 &4 ]

  1. Press button 3 to Shift (the red LED is on for indication),
  2. and press button 4 to initiate semi-auto mode. The fixture is manually on by push-switch and automatically off in semi-auto mode.

Power output [ button 5]

Press button 5, the light output shifts between 80% and 100%.
Note: the function of “Sensor off” and “Twilight” are disabled.

Brightness +/- [ button 6]

Press button 6 to adjust the light brightness to reset the target lux level.

Scene prog. [ zone ] (One-key-commissioning)

  1. Press the button “Start” to program.
  2. Select the buttons in 8 “Detection range”, 9/10 “Daylight threshold”,11 “Hold time”,12 “Stand-by time”,13 and “Stand-by dimming level” to set all parameters.
  3. Press the button “Memory” to save all the settings programmed in the remote control.
  4. Press the button “Apply” to set the settings for each sensor unit(s). For example, to pre-set detection range 100%, daylight threshold Disable, hold time 5min, stand-by time +∞, stand-by dimming level 30%, steps should be: Press button 7 Start, button 8 100%,10 Disable, 3Shift,11 5min, 3Shift, +∞ , 13 30%, 7 Memory. By pointing to the sensor unit(s) and pressing Apply, all settings are passed on to the sensor(s).

Detection range [ zone 8]
Press buttons in zone 8 to set the detection range at 100% / 75% / 50% / 10%.

Daylight threshold [ zone 9]
Press buttons in the zone to set the daylight sensor at 2Lux / 10Lux / 50Lux / 100Lux / 300Lux / 500Lux or Disable.
Note: 2lux / 10lux are disabled. To set daylight sensor at 100Lux / 300 Lux / 500Lux, press 3 button Shift at first.

Ambient daylight threshold [ button 10]

  1. Press the button 3 Shift, the red LED is on for indication.
  2. Press button 10, and the ambient lux level is sampled and set as the new daylight threshold/target Lux level.

Hold time [ zone 11]

Press buttons in the zone 11 to set the hold time at 2s / the 30s / 1min / 5min / 10min / 15min / 20min / 30min.
Note:

  1. To set hold-time at 30s / 5min / 15min / 30min, press the button 3 Shift at first.
  2. 2s is for test purposes only, stand-by period and daylight sensor settings are disabled in this mode

To exit from Test mode, press button 2 or any button in zone 11.

Stand-by time [ zone 12]

Press buttons in zone 12 to set the stand-by period at 0s / 10s / 1min / 5min / 10min / 30min / 1h / +∞.
Note: “0s” means on/off control; “+∞” means bi-level control, 100% on when motion detected, and remains at the stand-by dimming level when no presence after hold-time.

Stand-by dimming level [ zone 13]

Press buttons in zone 13 to set the stand-by dimming level at 10% / 20% / 30% / 50%.

Daylight harvest auto-configuration function

  1. Press the button “Shift”, the red LED is on for indication.
  2. Select a time period and the sensor will do light level measurement and determine/save the lowest light level (commission line) with 100% light on, so as to set the target lux level automatically.

Note:

  1. Make sure the light level measurement covers the nighttime.
  2. The fixture will go into sensor mode after the measurement, all sensor settings remain unchanged.

Dual tech & RF mode [ zone 14]

All buttons in zone 14 are disabled.

Hytronik Industrial Ltd. | www.hytronik.com
3rd Floor, block C, complex building, 155#, Bai’gang road south,
Bai’gang village, Xiao Jin Kou town, Huicheng district, Huizhou 516023
Tel: 86-752-2772020 Fax: 86-752-2777877

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

HYTRONIK User Manuals

Related Manuals