PROEMION CANlink mobile 3000 Telematic Device User Guide
- June 3, 2024
- PROEMION
Table of Contents
- About this Quick Start Guide
- Provisioning and GoLive
- Unpacking the Launch Kit
- Connecting the Device to a PC
- Installing Proemion Configurator
- Installing Demo Configuration
- Perform a functional Test
- Check and adjust DataPortal
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CANlink mobile 3000 Telematic Device
User Guide
About this Quick Start Guide
This document is part of the CANlink mobile 3600 series documentation and
provides information regarding installation and configuration of the CANlink
mobile 3600 and the first steps with the Launch Kit.
The document is intended for qualified technicians and electricians with
advanced knowledge in electrical engineering and field bus systems, allowing
them to assess the risks and hazards of operating the device and to integrate
it into systems with components of other manufacturers.
It provides a quick overview of how to set the CANlink mobile into operation
with the DataPlatform when receiving the first device together with our Launch
Kit. We also assume, that a DataPlatform account setup has been ordered and
the technical contact person at the customer has received the information
about the setup completion.
| Machine-CU| CU Platform| Platform – User
Tools| Configurator| PDC builder/XML Editor| Web platform
Configuration is stored as …| DOD file| PDC file| Organisation tree, User
management
Figure 1. General system overview
1.1. Further information
For a comprehensive information about the several components, please refer to
these manuals:
- CANlink mobile Device Manual
- DataPortal User Manual
- PDC Manual
1.2. Onboarding best practice
Due to our experience in integrating a telematics solution into a fleet of
machines, we would like to recommend the following best practice for the
initial start-up of a CANlink mobile together with your data platform access:
- Create a laboratory setup with the device and the launch kit or starter kit.
- Configure the device for your application with our Proemion Configurator software.
- Activate the device.
- Create a PDC file to display the recorded signals on the data portal and assign it to the device via the management portal.
- Check the connection of the device to the data platform and the data transmission and display in your laboratory setup e.g., with simulated CAN messages.
- Install the device in a real machine and wire it as described in the device manual.
- Now check the functionality on the real machine.
- First roll out the new setup on a smaller set of pilot machines to prove the solution before using it in the complete fleet.
This document will guide you through the steps necessary for your initial setup.
Provisioning and GoLive
Provisioning allows you to make a machine with a telematics unit
installed available on the DataPortal. The machine will be visible and during
the process you can assign a model and change the machine name, serial number
and PIN/VIN.
GoLive is the automated activation of a communication unit (CU) after
Provisioning. Once the CU has been activated, it is authorized to connect to
the DataPlatform and transfer data.
- Login to the Proemion DataPortal User Manual
- Login with your username and password
- Provision the CANlink mobile to make it visible on your DataPortal account as described in the DataPortal > Provisioning
- Use DataPortal > GoLive to activate the device and permit DataPortal communication
INFORMATION For the first time login, the initial password must be set.
Please use the “Forgot password” function on
DataPortal. Enter the username which was
provided along with the account setup confirmation email.
Another email with instructions on how to reset the password will be sent to
your email address.
INFORMATION Please note that the activation of the SIM card can take up to
24 hours in exceptional cases.
Unpacking the Launch Kit
The CANlink mobile 3600 Launch Kit (253000176) consists of the following
components
CLM 3600 Starter Cable (136000202)
Antenna LTE GNSS DA 3M0 FAKRA-D FAKRA-C FAR (157000109)
CANview USB (253001014)
CAN bus terminator D-Sub/D-Sub, 120Ω (157000033)
USB Cable for CANview USB (136000119)
Power Supply Unit With Set Of Connectors (US, EU, UK, AU) and adapter (257004007)
USB Cable (Debugging, Diagnosis), Micro USB Type B (136000138)
USB Cable (Bootloader, Firmware Update), Micro USB Type A (136000199)
Assembly Set M5 Housing GH1208 (141000017)
Cable MTII 14pin Code1 14open 2m (136000198)
CANlink mobile 3000 Plug-Kit (132600031)
Product Information leaflet (144000133)
Figure 16. Product Information Leaflet
For further information regarding the components of the Launch Kit, please refer to the CANlink mobile Device Manual > Launch Kit.
Connecting the Device to a PC
Connect the CANlink mobile 3600 to your PC as shown in the image below. Please use the components from the Launch Kit.
- CANlink mobile
- CLM 3600 Starter cable
- Antenna
- CAN bus termination resistor 120 Ohm
- CANview USB
- Power supply
- USB cable
- PC
Please also refer to CANlink mobile Device Manual > Connecting the Device.
INFORMATION
Please be aware that the CANlink mobile 3600 is not equipped with an
integrated CAN bus termination resistor. The displayed labatory setup above
will work with just one CAN bus termination resistor. When doing the system
integration at the intended machine, it must be ensured that the CAN bus is
terminated with a CAN bus termination resistor of 120 Ohm at each end of the
CAN bus line. Please also refer to CANlink mobile Device Manual > Can Bus
Termination.
Installing Proemion Configurator
Install the latest version of the Proemion Configurator from our Download Center.
In case of problems, the Connectivity Check utility can be used to check the connectivity of our software tools with our services from your site’s network.
Installing Demo Configuration
A demo configuration for your CANlink mobile type is available at our
Download Center
Open the corresponding demo configuration file named like
clm36xx_Proemion_DemoConfig.DOD with the Proemion Configurator software.
Install the configuration to the device as described in CANlink mobile Device
Manual > Configuration Update.
For further information on how to create a customized device configuration,
please refer to the CANlink mobile Device Manual > Customtizing Demo
Configuration File.
Perform a functional Test
This work step is aimed to simulate the configured CAN messages with a CAN
Monitor software and its corresponding CAN-PC gateway.
In this case you can use the RM CAN Device Monitor and the CANview USB for a
functional test. Other CANPC gateways and software may also work for this
test.
Install the RM CAN Device Monitor which can be found in the Download
Center at folder
157002059_PROEMIONtools_CD\05_Utilities\01_RM CAN Device Monitor.
Ensure that the device is wired according to chapter Connecting the Device to
a PC.
Cyclic send a few sample CAN messages which are configured within the
installed configuration of the CANlink mobile in the Receive CAN Messages
section.
Table 1. The following messages can be used for test:
J1939-PGN| SPN| CAN ID| Type| DLC| Data Bytes|
Signal
---|---|---|---|---|---|---
61444| 190| 0x18F00400| Ext| 8| 00 00 00 80 25 00 00 00| = 1200 rpm
65262| 110| 0x18FEEE00| Ext| 8| 7D 00 00 00 00 00 00 00| = 85°C
Check the status LEDs of the CANlink mobile. The device should be powered on
and indicate reception of CAN messages. Please also refer to CANlink mobile
Device Manual > Indicator Elements.
In case that there is access to a real machine which is also transmitting the
configured CAN messages, the CANlink mobile 3600 can be also connected to the
corresponding CAN bus.
Notice CAN bus errors possible! Please make sure that the configured CAN
baud rate is matching the controller CAN baud rate of the machine.
Check and adjust DataPortal
In the last step you check and adjust the DataPortal appearance for your machine’s signals.
- Login to your DataPortal account
- Ensure that the customer default model with the demo PDC is assigned to the machine
- Check the displayed signals for your Machine within the DataPortal.
- Modify the machine details page with customized widgets according to your preferences. Please also refer to the DataPortal User Manual>Widget Introduction/Catalog.
To get further information about creation and adjustment of customized PDC
files, please refer to the DataPortal User Manual>Administration Menu>PDC
Management.
Version: 11.0.335
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>