IMPORTANT SAFEGUARDS

When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS

  1. DANGER- Risk of shock- Disconnect power before installation.
  2. This luminaire must be installed in accordance with the NEC or your local electrical code. If you are not familiar with these codes and requirements, consult a qualified electrician.
  3. Min 90°C supply conductors.
  4. Wait until fixture has cooled down before installing or servicing the fixture.
  5. Please read and understand all instructions thoroughly before installing any part of the Track system.

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

NOTES:

  • All E-conolight Track sections are manufactured with a Polarity Groove.
  • All E-conolight Track fixtures are manufactured with Indicator Arrows designed to point toward the Polarity Groove once installed. See Figures 1-2.
  • E-conolight Track fixtures are UL® Classified for use with E-conolight E-K1 and E-K2 Series, and Juno® (not affiliated with E-conolight) T and TU Series track systems only.
  • All E-conolight Track fixtures are supplied with a Contact Support to convert fixture from Single Circuit installation to Two Circuit Installation. See Figure 3.

TO INSTALL:

CREE LIGHTING S CT FB B Essentia Series LED Track
Head-

FIXTURE INSTALLATION – SINGLE CIRCUIT TRACK

STEP 1:
Insert Brass Contact on top of Track Adaptor into the Track Channel. See Figures 1 and 3.
STEP 2:
Rotate the Track Adaptor 90° so that the Indicator Arrows point toward the Polarity Groove once installed. See Figure 2. Pull Adaptor Latch down as you rotate Track Adaptor in order for Latch to clear track edge and allow it to snap into place in the track.
STEP 3:
To remove or relocate track fixture location, pull Adaptor Latch down, rotate the Track Adaptor 90° away from the Polarity Groove and remove.

CREE LIGHTING S CT FB B Essentia Series LED Track Head-
fig1

CREE LIGHTING S CT FB B Essentia Series LED Track Head-
fig2

FIXTURE INSTALLATION – TWO CIRCUIT TRACK

STEP 1:
To install track fixture into lower circuit of two-circuit track, follow directions for single circuit installation.
STEP 2:
To install track fixture into upper circuit of two-circuit track, raise the Brass Contact labeled “P” by grasping Contact with needle nose pliers and pulling up into position. See Figure 3.
STEP 3:
Insert Contact Support by tipping and positioning it under the “P” Contact. See Figure 3. Snap Contact Support in place.
NOTE: Once the contact support is in place, make sure the “P” contact is fully seated in the support by using the needle nose pliers to push the “P” contact into place.
STEP 4:
Refer to instructions 1-3 under “Fixture Installation on Single Circuit
Track” section.

LENS REPLACEMENT (CLEAR LENS INSTALLED)

STEP 1:
Before attempting Optical Lens Replacement, remove fixture from track.
STEP 2:
Remove front bezel. See Figure 4.
STEP 3:
Remove clear lens from bezel and replace with frosted lens.
STEP 4:
Push front bezel back into position. See Figure 5.
STEP 5:
Reinstall fixture onto track.

FCC NOTICE

CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. CAN ICES-005 (A)/NMB-005 (A)

© 2021 Cree Lighting, A company of IDEAL INDUSTRIES. All rights reserved. For informational purposes only. Content is subject to change. See www.creelighting.com/warranty for warranty and specifications. Cree® and the Cree Lighting logo are registered trademarks of Cree, Inc.

CREE LIGHTING -logoA COMPANY OF IDEAL INDUSTRIES, INC.
www.creelighting.com
LPN00861X0002A1_A

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

CREE LIGHTING User Manuals

Related Manuals