POWER PROBE PPDMM Digital Multimeter User Manual
- June 3, 2024
- POWER PROBE
Table of Contents
POWER PROBE PPDMM Digital Multimeter
GENERAL SPECIFICATIONS
- Operating Altitude: 2000m
- Relative Humidity: 75% max operating
- Operating Temperature: 0°C-40°C/32°F-104°F (<80% RH)
- Storage Temperature: -10°C-60°C/14°F-140°F (<70% RH)
- Accuracy Temperature: -18°C-28°C/64°F-82°F (<80% RH)
- Temperature Coefficient: 0.1x(specified accuracy)/°C (<18°C or >28°C)
- Sampling Frequency: approx. 3 times/sec.
- Fuse Protection: µNmA input: F600mN600V 10A input: F10N600V
- DC/AC Voltage: 600V
- DC/AC Current: 10A
- Resistance: SOMO
- Capacitance: 60mF
- Frequency: 10kHz
- Diodes: 2.7V
- Continuity: <500
- Temperature: -2o·c-1ooo·c1-4°F-1832°F
- LCD Display: 3 ¾ digit display (6000 counts)
- Product Supply: 3×1.SV AAA batteries
- Product Size: 160mmx74mmx49mm / 6.3″x2.9″x1 .9″
- Product Weight: 482g / 1.06Ib
- Safety Rating: CAT IV 600V; pollution degree: II
- Safety Standards: IEC61010-1
- Pollution Degree: 2
- Accuracy: ±(of reading+# of least significant digits)
WARNINGS
To avoid electric shock and injury or damage to the meter, observe the
following safety methods:
- Check the meter before use to make sure there was no damage during transit.
- Check that the insulation on the test leads is not damaged and/or wires are not exposed.
- If any faults or abnormalities are observed, the meter should not be used and should be checked out prior to use.
- Never exceed the protection limit values indicated in specifications for each range of measurement.
- Always be careful when working voltages above 60V DC or 30V AC rrns, keep fingers behind the probe barrier while measuring.
- Make sure the rotary switch is in the correct position before measurement.
- Never use the meter in an environment with explosive gas, vapor or dust.
- Always keep fingers behind probe barriers when making measurements
WARNINGS
- When connecting test leads to a circuit, connect the black test lead first, then the red lead. Disconnect in the opposite order.
- Turn off power and discharge all capacitors first before measuring resistance, continuity or diodes.
- Failure to follow safety guidelines could compromise the safety features of this meter.
- Do not use the meter without the battery cover in place.
- Replace the batteries as soon as the low battery symbol “” to avoid false reading that could lead to electric shock and injury.
- Remove test leads from all circuits before opening the battery cover.
SAFETY SYMBOLS
Im tant safety information | |
---|---|
Ground | |
DC(direct current) | |
AC (alternating current) | |
DC/AC Voltage or Current | |
Double insulation protection |
| ****
Fuse
| ****
Compliance with EU regulations
FEATURE DETAILS
-
LCD Display
-
Hold/Backlight Button
Press to hold the current reading on the display. Press the button again to release the hold Hold “ to turn on the backlight. Hold the button again to manually turn off the backlight. -
Max/Min Button
In all modes (except continuity, diode, capacitance), press Max/Min” and the display will show the maximum value recorded since the button was pressed. Press the button again and the display will show the minimum value recorded. Pressing the button a third time will show the difference between the max and min value. Hold “Max/Min” to return the display to normal readings. -
Function Switch Button
Press “FUNC” to switch between functions or between AC/DC current. -
Frequency/Duty Cycle Button (Hz/%)
In AC voltage/current modes, press “Hz%” and the display will show the frequency measurement. Press the button again to switch to duty cycle. Press the button a third time to return to normal display. -
Range Button
In voltage, current and resistance modes, the default range is auto. To enter manual range, press “RAN”. Each press of the button increases the range, and returns to the lowest range when pressed in the highest range. Hold “RAN” to return to auto range. (Only auto range is available in capacitance mode) -
Relative Measurement Button
In all modes (except resistance, continuity, diode), press “REL” and the display will show the relative value, i.e. the difference between |the stored value when the button was pressed and the currently measured value. (REL = stored value – currently measured value) Press the button again to return the display to normal. (In REL mode, auto range is disabled) -
Rotary Switch
-
Input Jack (all measurements; current below 600mA)
-
A Jack (current measurements between 600mA-10A only)
-
Common Jack (all measurements)
DISPLAY FUNCTION INSTRUCTIONS
- Direct Current
- Alternating Current
- Negative DC Value
- Auto Power Off
- Data Hold
- Auto Range Active
- Maximum Display Minimum Display
- Relative Display Diode Test
- Continuity Test
- Low Battery
- Temperature in Celsius
- Resistance
- Frequency
- Capacitance
- DCIAC Current
- DC/AC Voltage
- Main Display
ROTARY SWITCH FUNCTION INSTRUCTIONS
DC Voltage: <600V
AC Voltage: <600V
DC Current (large): <10A
AC Current (large): <10A
DC Current (middle): <600mA
AC Current (middle): <600mA
DC Current (smallM): <6000uA
AC Current (small): <6000uA
Resistance: <60MQ
Continuity: <500
Diode Test: <1V
Capacitance: <60mF
Temperature: -20°C-1000°C/-4°F-1832°F
ELECTRICAL SPECIFICATIONS
DC Voltage Measurement
Range| Resolution| Accuracy
600mV| 0.1mV| ****
% of reading +2 digits)
6V|
60V| 0.01V
600mV| 0.1V
- Input impedance: 1OMO
- Max. input voltage: 600V rms
Range
V
| Resolution
0.1mV
| Accuracy
.0% of reading +5 digits)
---|---|---
6V|
60V| 0.01V
600mV| 0.1V
- Input impedance: 1OMQ
- Max. input voltage: 600V rms
- Frequency response: 40-400Hz, calibrated to rms of sine wave (average response)
Range| Resolution| Accuracy
600µA| 0.1µA|
of reading +5 digits)
6000µA|
60mA| 0.01µA
600mA| 0.1µA
10A| 10mA| ±(2.0% of reading +10 digits)
- Overload protection: PA/mA input: Fuse (F600mA/600V) 10A input Fuse (F10A/600V)
- Max. input current: UA/mA input: 600mA rms 10A input: 10A rms
AC Voltage Measuremen t
e| Resolution| Accuracy
| 0.1µA|
of reading +5 digits)
6000µA|
60mA| 0.01µA
600mA| 0.1µA
10A| 10mA| ±(2.5% of reading +10 digits)
- Overload protection: HA/mA input: Fuse (F600mA/60OV) 10A input Fuse (F10A/600V)
- Frequency response: 40-400Hz calibrated to rms of sine wave (average response)
- Max. input current: |HA/mA input: 600mA rms 10A input: 10A rms
e Measuremen t
Rang| Resolution| Accuracy
6000| 0.10|
±(0.8% of reading +5 digits)
6kO|
60kO| 0.01kO
600kO| 0.1kO
6MQ| 0.001MO
60MQ| 0.01MO| ±(2.0% of reading +5 digits)
- Max. input voltage: 600V rms
- Max. input voltage: 600V rms
- Max. input voltage: 600V rms
Range| Resolution
0.001nF
| Accuracy
±(4.0% of reading +10 digits)
---|---|---
10nF| | ****
±(3.0% of reading +10 digits)
100nF| 0.1nF
1µF| 1nF
10µF| 10nF
100µF| 100nF
1mF| 1µF
10mF| 10µF| ****
±(4.0% of reading +10 digits)
60mF| 10µF
- Max. input voltage: 600V rms
equency | (cont.) | (AC voltage) |
---|---|---|
Resolution | Accuracy | |
99.99H | 0.01Hz |
of reading +5 digits)
999.9Hz|
9.999kHz| 0.001kHz
10kHz| 0.01kHz| Reference only
- Signal input range: 20.2V AC rms (voltage input will increase as frequency increases)
- Input impedance: 10MQ
- Max. input voltage: 600V rms
ency (cont.) (AC voltage )
Ran| Resolution| Accuracy
99.99Hz| 0.01Hz|
reading +5 digits)
999.9Hz|
1kHz| 0.001kHz| Reference only
- Signal input range: uA: 2 60uA rms mA: 2 6mA RMS A: 20.6A rms (current input will increase as frequency increases)
- Max. input voltage: 10A rms
Range | I | Resolution | I Accuracy |
---|---|---|---|
-20°C- 1000°C | I | I |
±(2. 0% of reading +3 digits)
-4 ° F- 1832 °| I| I
- Overload protection: Fuse (F600mA600V)
CANADA & USA
Power Probe Group, Inc. cs.na@mgl-intl.com 2810 Coliseum Centre Drive, Ste. 100. Charlotte, North Carolina 28217 USA Tel: +1 833 533-5899
700020287 SEP 2021 V1
2021 MGL International Group Limited. All rights reserved. Specifications are subject to change without notification.