Description

Noncontact Themometer detects the infrared ray that an object emits, The instrument foculizes infrared energy of the object onto a sensor through a lens, changes the surface temperature into electric signal, a microcomputer calculates and displays the measurement temperature on the LCD.

  • Single-spot Laser Sighting
  • Backlit Display
  • Current Temperature Plus MIN, MAX, AVG Temperature Displays
  • Preset Emissivity 0.95

Warning

  • Please read the following information carefully before using the meter.Protection is impaired if used in a manner not specified in this manual
  • Do not clear the meter using solvents.
  • Keep the instrument clean, and do not get dust into detecting hole.
  • Do not point laser directly at eye or indirectly off reflective surfaces.
  • Laser :class 2 <1mW/630-670nm
  • Laser radiation is classified according to IEC 60825-1: 2014-05, Safety of laser products

Part 1 : Equipment classification and requirements.

CAUTION

  • LASER RADIATION-DO NOT STARE INTO BEAM.
  • AVOID EXPOSURE-LASER RADIATION IS EMTTED FROM THIS APERTURE
  • MAX OUTPUT <1mW,WAVELENGTH 630~670nm,CLASS 2 LASER PRODUCT

WARNING
Laser radiationwhen open do not stare into beam.

Panel

POWER PROBE-IRGUN500-Infrared-Thermometer-fig-
\(3\)

  1. Screen
  2. Mode key
  3. Backlight key
  4. Laser key
  5. °C/°F key
  6. Sensor
  7. Laser
  8. Trigger
  9. Battery cover

Display

  1. Laser indicator
  2. Scan status
  3. Emissivity
  4. Low battery
  5. °F unit
  6. °C unit
  7. Secondary display
  8. Min value
  9. Max value
  10. Average value
  11. Primary display
  12. Surface scan
  13. Hold status

D:S ratioPOWER PROBE-IRGUN500-Infrared-Thermometer-fig-
\(5\)

Make sure that the target is larger than the meter’s visual spot size. The smaller the target, the closer you should be to it. The relationship between distance and spot size is 10:1

Operating Thermometer

  • To measure temperature, pull and hold trigger.
    Release the trigger to hold a temperature reading.
    The meter turns off when no activity is detected for ten seconds.

  • Press key to toggle between the MAX ,MIN,AVG value.

  • Press key to Active the laser.

  • Press key to light on or off the backlight.

  • Press key to switch between °C or °F.

Note1 Make sure that the target is larger than the meter’s visual spot sizePOWER PROBE-IRGUN500-Infrared-Thermometer-fig-
\(7\)

Note2
When ambient temperature changes quickly, must wait 30 minutes to balance the temperature of the instrument before use.

Note1
When the battery voltage is lower, the battery symbol appears, it indicates that we must change the batteryPOWER PROBE-IRGUN500-Infrared-Thermometer-
fig- \(9\)

WARNING
Do not mix old and new batteries. Do not mix alkaline,standard (carbon- zinc),or rechargeable (ni-cad,ni-mh,etc) batteries

Specifications

Temperature range -20°C~500°C(-4°F~932°F)

Accuracy: Assumes ambient

Operating temperature

(23°C ± 2°C or 73°F±3°F)

| -20°C~0°C(±3°C)

-4°F~32°F(±5°F) 0°C~500°C ±(2.0%rdg+2°C)

32°F~932°F(2.0%rdg+3°F)

Optical resolution| 10:1| Spectral response| 8-14 um
Repeatability| 1°C| Response time| Approx.1s
Resolution| 0.1°C/0.1°F| Emissivity| 0.95
Ambient Operating Range| 0~40°C| Relative humidity| 10%~90%
| Conforms to: EN61326 EN61010-1 EN60825-1|

Laser

| <1mW 630-670nm

class2

****| CONFORMS TO UL STD 61010-1, CERTIFIED TO CSA STD C22.2 No.61010-1|


Dimensions

| ****

143×99×47mm

Power| 2×1.5V AAA| Weight| Approx.160g

Parque Empresarial Argame, 33163 Morein.
Asturias, Spain.
Tel: +34 985-08-18-70
MEXICO & LATAM
Power Probe Group, Inc. G) cs.latam@mgl-intl.com Colonia Industrial Vallejo Del. Azcapotzalco 02300, Mexico D.F
Tel: + 1 833-533-5899
UNITED KINGDOM
Power Probe Group Limited 0cs.uk@mgl-intl.com 14 Weller St, London, SE1 1 OU, UK
Tel: +34 985-08-18-70
www.powerprobe.com
Incorporated with MGL
700019619 JUN 2021 V1
©2021 MGL International Group Limited. All rights reserved. Specifications are subject to change without notification.
SKU Number : PPIR500

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

POWER PROBE User Manuals

Related Manuals