STMicroelectronics EVALST-3PHISOSD Evaluation Board User Manual
- June 3, 2024
- STMicroelectronics
Table of Contents
UM3107
User manual
EVALST-3PHISOSD evaluation board
Introduction
The EVALST-3PHISOSD evaluation board implements a 3-phase AC/DC current meter
that meets the requirements for motor control applications using low-cost,
electromagnetic-immune shunt sensors and advanced galvanic-isolation
technology.
The evaluation board is based on the high-accuracy ISOSD61 Isolated Sigma-
Delta Converter front-end IC, with customizable firmware running on an STM32
microcontroller.
The ISOSD61, a single-channel second-order sigma-delta modulator, measures
current for each phase through a shunt current sensor. It oversamples the
signal using a synchronized clock distributed by the microcontroller and
outputs the converted current sigma-delta bitstream. Three ISOSD61 are used in
the 3-phase system to collect the current data from each phase.
Through an isolation barrier based on a thick-oxide technology, the internal
digital transceiver transfers data between the isolated domains and guarantees
6 KV VIOTM and 1.2 KV VIORM between the phases.
The firmware implemented on the STPM32F413 uses digital filters for sigma-
delta modulator (DFSDM) peripheral to convert modulated data into 24-bit
current values and computes all data in real-time every 200 μs.
The firmware also implements a virtual COM port that provides access to
internal parameters for reading data and calibrating the board.
Safety and operating instructions
1.1 General terms
Warning: During assembly, testing, and operation, the evaluation board
poses inherent hazards due to high voltage.
Danger: There is danger of serious personal injury, property damage or
death due to electrical shock if the kit or components are improperly used or
installed incorrectly.
The kit might be electrically connected to high-voltage supply AC/DC inputs.
The evaluation board might be directly linked to the mains voltage. No barrier
is present between the accessible parts and the high voltage. All measuring
equipment must be isolated from the mains before powering the board. When
using an oscilloscope with the demo, it must be isolated from the AC line.
This prevents shock from occurring because of touching any single point in the
circuit but does NOT prevent shock when touching two or more points in the
circuit.
All operations involving transportation, installation, use, and maintenance
must be performed by skilled technical personnel able to understand and
implement national accident prevention regulations. For the purposes of these
basic safety instructions, “skilled technical personnel” are suitably
qualified people who are familiar with the installation, use, and maintenance
of power electronic systems.
1.2 Intended use of evaluation board
The evaluation board is designed for demonstration purposes only. Technical
data and information concerning the power supply conditions are detailed in
the documentation and should be strictly observed.
1.3 Installing the evaluation board
The board contains electrostatically sensitive components that are prone to
damage if used incorrectly. Do not mechanically damage or destroy the
electrical components (potential health risks).
1.4 Operating the evaluation board
To properly operate the board, follow these safety rules.
-
Work area safety:
– The work area must be clean and tidy.
– Do not work alone when boards are energized.
– Protect against inadvertent access to the area where the board is energized using suitable barriers and signs.
– A system architecture that supplies power to the evaluation board must be equipped with additional control and protective devices in accordance with the applicable safety requirements (that is, compliance with technical equipment and accident prevention rules).
– Use a non-conductive and stable work surface.
– Use adequately insulated clamps and wires to attach measurement probes and instruments. -
Electrical safety:
– Proceed with the arrangement of measurement setup, wiring, or configuration paying attention to high voltage sections.
– Remove power supply from the board and electrical loads before performing any electrical measurement on the high voltage sections of the board.
– Once the setup is complete, energize the board.
Parts of the kit are not electrically isolated from the AC/DC input. The USB interface, the JTAG connector and the strip line connector are in the low voltage side of the board, so they can be used to connect a host computer. Please refer to Figure 2. -
Personal safety:
– Always wear suitable personal protective equipment such as, insulating gloves and safety glasses.
– Take adequate precautions and install the board in such a way to prevent accidental touch. Use protective shields such as, an insulating box with interlocks if necessary.
Getting started
2.1 Hardware and software requirements
Using the EVALST-3PHISOSD evaluation board requires the following software and
hardware:
-
A Windows PC (XP, Vista, Win 7, Win 8, Win 10) to eventually install the software package available on www.st.com or to communicate through the mini-shell.
-
A ‘USB type A to Micro-B’ cable, used to power on the board (through USB connector CN1) from host PC and to allow communication with terminal or software GUI.
-
JTAG Arm debugging probe (optional).
-
3-Ph AC power supply and 3-Ph load or a 3-Ph controlled motor system application.
-
Reference ammeter (optional).
The system could be run and evaluated in the following ways: -
Installing the software GUI. In this case, please refer to the related documentation.
-
Connecting to a shell terminal on the host PC.
-
Using a JTAG Arm debugging probe can be connected to JTAG connector for debugging and programming.
For this purpose, it is necessary to install the IDE “IAR Embedded Workbench® for Arm” version 8.5.
2.1.1 Hardware description
2.1.1.1 Power supply
The board can be supplied alternatively:
- Connecting a USB cable to the PC
- Providing 5 V DC by the coaxial jack
Each phase ISOSD61 is supplied by an independent integrated DC-DC power supply, providing the necessary 5 V to the device.
2.1.1.2 Board ratings
The maximum current rating of the board for each phase is 50 ARMS.
2.1.2 Running the built-in demonstration
The board comes with the demonstration firmware preloaded in the flash memory.
Before running your application, you should establish the connection with the
board.
Follow the steps below to run it:
-
Connect the board to a PC with a ‘USB type A to Micro-B’ cable through USB connector CN1 to power the board. Green LED (PWR ON) then lights up.
-
Connect the board to a 3-phase generator and load as shown in Figure 4, or to the current branches of the motor (Figure 5), then power on the generator/motor supply:
-
Connect a shell terminal to the board virtual COM port as specified in section 4.1 below.
-
Alternatively, use the software GUI to read data. For more details on the GUI refer to its User manual.
-
For application development and debug, connect the JTAG probe and open the “IAR Embedded Workbench for Arm” IDE. For FW details, refer to related User manual.
2.2 Register access through mini-shell
It is possible to access the calibration and samples data by connecting to the
virtual serial COM port associated to the board with the following settings:
- Baud rate: 115200
- Handshake: Request to send
- Parity: None
- Data bits: 8
- Stop bits: 1.
To communicate with the board, use the command set in Table 1, where:
-
could be 1, 2 or 3; - is the address or the register to read, as in the second column of the registers’ map in Table 2;
-
is the number of registers to read, the maximum is 70. Consider that some of the registers are unused, they are not listed in Table 2 but are actually present in the memory structure. It is necessary to take them into account when requesting a read or write access on several registers.
Table 1. Minishell commands
Command | Data received |
---|---|
met metro 5 1 |
Current sample |
met metro 22 1 |
Current samples buffer |
met metro 23 1 | DFSDM peripheral settings |
met rd |
Read < Nb > registers starting from |
met wr |
Write < Nb > |
registers starting from
;Table 2. Register map
| Address| (R)ead (W)rite (L)atch| 31:28| 27:24|
23:20| 19:16| 15:12| 11:8| 7:4| 3:0| Name|
Default value
---|---|---|---|---|---|---|---|---|---|---|---|---
5| 0A| RW| | CHC [11:0]| DSPCTRL6| 00000800
7| 0E| RW| Padding| OFFC [23:0]| DSPCTRL8| 00000000
25| 32| RL| Padding| CSample [23:0]| DSP_REG3| 00000000
2.3 Accuracy results
Some of the accuracy test results after calibration are reported below.
● Revision history
Table 3. Document revision history
Date | Version | Changes |
---|---|---|
16-Nov-2022 | 1 | Initial release. |
24-Nov-2022 | 2 | Minor text change. |
IMPORTANT NOTICE – READ CAREFULLY
STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make
changes, corrections, enhancements, modifications, and improvements to ST
products and/or to this document at any time without notice. Purchasers
should obtain the latest relevant information on ST products before placing
orders. ST products are sold pursuant to ST’s terms and conditions of sale in
place at the time of order acknowledgment.
Purchasers are solely responsible for the choice, selection, and use of ST
products and ST assumes no liability for application assistance or the design
of purchasers’ products.
No license, express or implied, to any intellectual property right is granted
by ST herein.
Resale of ST products with provisions different from the information set forth
herein shall void any warranty granted by ST for such product.
ST and the ST logo are trademarks of ST. For additional information about ST
trademarks, refer to www.st.com/trademarks.
All other product or service names are the property of their respective
owners.
Information in this document supersedes and replaces information previously
supplied in any prior versions of this document.
© 2022 STMicroelectronics – All rights reserved
UM3107 – Rev 1
UM3107 – Rev 1 – November 2022
For further information contact your local STMicroelectronics sales office.
www.st.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>