STMicroelectronics STSW-WBC2STUDIO Software User Guide

June 1, 2024
STMicroelectronics

STMicroelectronics STSW-WBC2STUDIO Software

STMicroelectronics-STSW-WBC2STUDIO-Software-product

Introduction

  • The purpose of this document is to provide a comprehensive user guide for the STSW-WBC2STUDIO software. It aims to provide clear instructions on how to install, execute, and use the features provided by the software.
  • This document is intended for end-users of the STSW-WBC2STUDIO software, who have all the required hardware settings. The scope of this document is limited to the STSW-WBC2STUDIO software.

Abbreviations, acronyms, and definitions

Abbreviations, and acronyms

Table 1. List of abbreviations

Abbreviation Description
UART Universal Asynchronous Receiver-Transmitter
HW Hardware
NVM Non-Volatile Memory
PRx Power Receiver
PTx Power Transmitter
Rx Receiver/Receive. Unless explicitly mentioned, this is used

interchangeably with PRx
Tx| Transmitter/Transmit. Unless explicitly mentioned, this is used interchangeably with PTx
UI| User Interface

Definitions

Table 2. List of definition

Name Description
application processor A microcontroller or microprocessor that controls the

device of interest. Typically, an application processor is the main processor of the system or subsystem in which the device is connected to


customer

| The person, or persons, who pay for the product and usually (but not necessarily) decide the requirements. In the context of this recommended practice, the customer and the supplier may be members of the same organization
host| A master system that controls the device of interest. In the case that the host is a microcontroller or microprocessor, it is referred to as an application processor
user| The person, or persons, who operate or interact directly with the product

System requirements

Table 3. List of system requirements

Description Minimum requirement
Operating system Microsoft® Windows® 10
Processor 1 Ghz processor
RAM 4 GBytes or higher (Minimum 8 GB preferred for better performance, 16 GB

recommended in debug mode)
Hard disk space| 15 Mbytes or more

Software installation

STSW-WBC2STUDIO software does not require specific installation steps. To execute the software:

  1. Extract the contents of STSW-WBC2STUDIO Vx.x.x.zip into C driver
  2. Double-click on STSW-WBC2STUDIO.exe to launch the software In case of using ST-LINK as a USB-UART bridge, install USB driver.

Hardware connection

Before starting the software, ensure the target evaluation kit is connected to the PC via a USB-UART bridge and powered up. The Table 4. The list of supported USB-UART bridges shows a list of ST-LINK bridges supported by the STSW-WBC2STUDIO software.
The STSW-WBC2STUDIO can connect one USB-UART bridge at a time for UART serial communication.
The Table 5. List of supported WLC evaluation kit lists the WBC2 evaluation kit supported by the STSW‑WBC2STUDIO software.
Figure 1. STSW-WBC2STUDIO HW connection

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-1

Table 4. List of supported USB-UART bridge

Part number Description
STLINK-V3SET USB-UART bridge
STLINK-V3MINI USB-UART bridge
STLINK-V3MINIE USB-UART bridge
USB-UART bridge Generic USB-UART bridge

Table 5. List of supported WLC evaluation kit

Part number PTx Description
STEVAL-WBC2TX70 PTx General application PTx up to 70 W
STEVAL-WBC2TX50 PTx General application PTx up to 50 W

Interface Description

The STSW-WBC2STUDIO main interface consists of three main sections: The top menu, the Side Menu Bar, and the Output Window.
The Side Menu Bar selects the output in the Output Window, details can be found in Section 5.2: Output Window. For details about the Top menu refer to Section 5.1: Top menu section.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-2

Top menu section
The Top Menu Section hosts the interface to access the software’s setup, settings, and information about the software.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-3

Table 6. Top menu UI element(s) description

UI element(s) Description
Expander Allows users to expand and collapse the Side Menu bar. This feature

allows the user to have a bigger view of the Output Window when needed
Connect| The toggle button allows you to connect or disconnect the WBC2 device
Settings| The Settings button opens the Settings window, for details refer to Section 5.1.1: Settings window
About| Opens the About window, for details refer to Section 5.1.2: About Window

Settings window

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-4

Table 7. Settings Window UI element(s) Description

UI Element(s) Description

Tx/Rx Settings

| Option to manually choose or auto-select com port for WBC2 UART

Option to choose WBC2 Param XML version


Charts Settings

| Configures chart plotting features

Buffer size [large: 100, medium: 50, small: 10] plot entries

Older data in plots are cleared to add new data when the plot entries exceed the configured size

Verbosity Settings| Enable traces based on category

About Window

Table 8. About Window UI element(s) Description

UI Element(s) Description
Product Version Software version number

Output Window

Info
Info Window displays the main metrics of running the STWBC2 device.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-6

Table 9. Info Window UI element(s) Description

UI Element(s) Description
Status Semaphore Provides current status of Tx device
Event box Display device status events. The clear button allows to

clear events
Device Metrics| Device metrics indicate the current status of the device
Tx Info| Hardware and Firmware details of the Tx device
Rx Info| The last identified power receiver information
Input Power Supply| Current input power supply of Tx device

Charts
Charts allow users to monitor key operational parameters in real-time. Chart settings are configurable in the Settings Window.
The maximum buffer size (period) available is 50 seconds. The data is plotted once every 500 ms and up to 4 different charts can be displayed at a time. The check box select option in Legend allows the user to choose charts for display. We recommend clearing the previously captured charts, using the Clear button, before starting a new capture.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-7

Table 10. Charts Window UI element(s) Description

UI Element(s) Description
Start/Pause The toggle button allows the user to start or pause

sampling and plotting
Clear| Clear existing plot(s)
Save| Save the current plot into a .csv file
Plot Area| Shows one or multiple plots
Legend| Legend for plot area. Click on the check box to enable/disable plotting

Table 11. Charts controller description

Action Gesture
Pan Right mouse button
Zoom Mouse wheel
Zoom by rectangle Ctrl+Right mouse button, Middle mouse button
Reset Ctrl+Right mouse button double-click, Middle mouse button double-

click
Show ‘tracker’| Left mouse button
Reset axes| ‘A’ , Home

Parameters
The parameters page allows the user to configure the device and to save and load the prepared configuration.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-8

Table 12. Parameters Window UI element(s) Description

UI Element(s) Description
Read Read from the device RAM and display in GUI
Write Write parameters configured in GUI to device RAM
Write NVM Write parameters configured in GUI to device RAM and NVM
Save Save Parameters to the configuration file
Load Load parameter configuration file to GUI
Parameters Display Display box for parameters in GUI

Traces
Traces are used to monitor key operating parameters of the device and to keep track of ongoing firmware tasks.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-9

Table 13. Traces Window UI element(s) description

UI Element(s) Description
Scroll Enables auto-scrolling to the latest Trace log
Backup Enables partial backup. When the trace buffer is full(2000

recordings), the traces are stored to the file and the Trace log is cleared
Start| The toggle button allows to Enable/disable trace logs to display. By default, traces shall be enabled
Clear| Clears Trace logs from the display
Save| Opens a dialog to save Trace logs to file, refer to Section 5.2.4.1: Traces save
Load| Loads of previously saved traces
Filter| Enables trace filter based on user selection
Information| Allows the user to click on individual traces for more details
Trace Log| Display box for traces

Traces save

Table 14. Traces save window UI element(s) Description

UI Element(s) Description
Save Save Trace logs to CSV file
Save Filtered Save only filtered trace logs to the CSV file
Save FOD Save traces to be used for FOD tuning

FOD tuning
Details about FOD tuning are separately available in the respective application notes.

FW
FW Window enables the user to load and change the firmware of the device. This Window allows *.hex format firmware file.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-11

Table 15. Programming Window UI element(s) Description

UI Element(s) Description
Load Select the firmware source file *.hex
Write Start programming firmware into the device NVM
Calibrate To execute calibration manually. It is recommended to perform

calibration after each firmware update
Read All| Allows users to read and save contents of the NVM (both firmware and Parameters) into a *.hex file. The generated file can also be used later in mass production

Log
The Log Window displays logs of all the UART transactions performed during any session. These logs may be saved into a file.

STMicroelectronics-STSW-WBC2STUDIO-Software-fig-12

Table 16. Log Window UI element(s) description

UI Element(s) Description
Debug Enables log level up to debug
Clear Clears the debug trace log
Save Saves current trace log into a .txt file
Scroll Enables auto-scrolling to the latest log
Backup Enables partial backup when the log buffer is full
Log Trace Display box for traces

Revision history

Table 17. Document revision history

Date Revision Changes
09-Feb-2024 1 Initial release.

IMPORTANT NOTICE – READ CAREFULLY

  • STMicroelectronics NV and its subsidiaries (“ST”) reserve the right to make changes, corrections, enhancements, modifications, and improvements to ST products and/or to this document at any time without notice. Purchasers should obtain the latest relevant information on ST products before placing orders. ST products are sold according to ST’s terms and conditions of sale in place at the time of order acknowledgment.
  • Purchasers are solely responsible for the choice, selection, and use of ST products and ST assumes no liability for application assistance or the design of purchasers’ products.
  • No license, express or implied, to any intellectual property right is granted by ST herein.
  • Resale of ST products with provisions different from the information set forth herein shall void any warranty granted by ST for such product.
  • ST and the ST logo are trademarks of ST. For additional information about ST trademarks, refer to www.st.com/trademarks. All other product or service names are the property of their respective owners.
  • Information in this document supersedes and replaces information previously supplied in any prior versions of this document.
  • © 2024 STMicroelectronics – All rights reserved

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

STMicroelectronics User Manuals

Related Manuals