  1. Pound conduit into ground or fasten deck mount.
    *Use 1″ (2.5 cm) sch 40 conduit for M-PL, M-PK, andM-PZ. Use ¾” (2 cm) sch 40 conduit for M-PJ.
  2. Use voltmeter to ensure 11 to 15 V at fixture.
  3. Connect wiring with waterproof connector.
  4. Slide fixture over conduit (or mount).
  5. Orient fixture position as desired. 5/6″ Allen Key.

CIRCUITING GUIDELINES

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the  fixtures as possible.

FXLuminaire M Series Path Lights - Figure 1

Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth.

Oil from skin may damage lamp.

  • Do not operate the luminaire fitting with a missing or damaged shield.
    WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.

  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.

  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.

These products contain a light source of energy efficiency class G.