INSTALLATION INSTRUCTION

  1. Change beam angle lens and color filter by rotating, removing, and replacing existing components (optional).
  2. Attach fixture to structure using selected mount.
  3. Use a voltmeter to ensure 11-15V at the fixture.
  4. Connect wiring with a waterproof connector.
  5. Orient the set screw in the downward direction. Aim fixture.

CIRCUITING GUIDELINES

FXLuminaire-3LED-DownLight-Metallic-
fig-6

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using numerous transformers, spread the load evenly across all transformers. Avoid voltage drops by installing the transformers as close to the fixtures as possible.

Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep light away from materials that may burn.
  • Do not touch the light at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected toa connector within 6″ (152 mm) from a building structure, a luminaire, or fitting.
  • This product contains a light source of energy efficiency class G.
  • CE Certified Down Lights: QT, DE, JB and MD Only Non-CE Certified Down Lights: C-DL
  • LANDSCAPE LIGHTING | Learn more. Visit fxl.com

Documents / Resources

| FXLuminaire 3LED DownLight Metallic [pdf] User Guide
DOWN LIGHT, QT, JB, DE, MD, C-DL, 3LED DownLight Metallic, 3LED, DownLight Metallic, Metallic Downlight, Downlight
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals