FXLuminaire XN-70 In-Grade Light Instruction Manual
- June 12, 2024
- FXLuminaire
Table of Contents
FXLuminaire XN-70 In-Grade Light
Product Information
The product is the Designer In-Grade Light XN. It has dimensions of 6.02 inches (153 mm) in height and 6.77 inches (172 mm) in width. The product operates at a voltage range of 11-15 V and has a power consumption of 12.5 watts. It is designed for use with the Luxor lighting system.
Product Usage Instructions
- Dig a hole, run wire, and fill the base with drainage material. Insert the preinstall kit and cover it.
- After construction, use a voltmeter to ensure that the fixture receives 11 to 15 V.
- Connect the wiring using a waterproof connector.
- Insert the fixture into the preinstall kit and secure it.
- To adjust the angle of the fixture, remove the faceplate and lens. Insert a screwdriver into the slot and tilt it to the desired angle.
- Secure the faceplate to complete the installation.
INSTALL
- Dig hole, run wire, and fill base with drainage material. Insert preinstall kit and cover.
- Post-construction, use voltmeter to ensure 11 to 15 V at fixture.
- Connect wiring with waterproof connector.
- Insert fixture into preinstall kit and secure.
- To adjust fixture angle, remove faceplate and lens. Insert screwdriver into slot and tilt to desired angle.
- Secure faceplate to finish installation.
CIRCUITING GUIDELINES
TRANSFORMERS
- Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
- Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.
For voltage drop calculation, visit fxl.com/voltage-drop- calculator.
Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at fxl.com/support.
WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:
- Turn off/unplug and allow to cool before replacing lamp.
- Lamp gets HOT quickly. Contact only switch/plug when turning on.
- Do not touch hot lens, guard, or enclosure.
- Keep lamp away from materials that may burn.
- Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
- Do not operate the fixture fitting with a missing or damaged shield.
WARNING – Risk of Electric Shock
- May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
- A fixture shall not use tungsten halogen lamps unless the fixture is marked for such lamps.
- Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.
LOW VOLTAGE CABLE SHALL:
- Be protected by routing in close proximity to the fixture or fitting, or next to a building structure such as a house or deck
- Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable
- Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, a fixture, or fitting
These products contain a light source of energy efficiency class G.