DESIGNER/STANDARD
WALL LIGHT | PO, MO, VO*, CG, CN
INSTALLATION
-
Use provided conduit, and trim length if necessary.
-
Install conduit sleeve into wall during construction.
Run fixture wiring through sleeve. *Coupling for VO fixture only. -
Use voltmeter to ensure 11 to 15 V at fixture.
-
Connect wiring with waterproof connector.
-
Press faceplate into sleeve. Level and orient fixture as desired.
*For concrete ground-mount option, use construction housing.
CIRCUITING GUIDELINES
LANDSCAPE & ARCHITECTURAL LIGHTING | Learn more. Visit fxl.com
TRANSFORMERS
Single transformer: When using one transformer, center the transformer on the
wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load
evenly across all transformers. Avoid voltage drop by installing the
transformers as close to the fixtures as possible.
Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at fxl.com/support.
WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:
-
Turn off/unplug and allow to cool before replacing lamp.
-
Lamp gets HOT quickly. Contact only switch/plug when turning on.
-
Do not touch hot lens, guard, or enclosure.
-
Keep lamp away from materials that may burn.
-
Do not touch the lamp at any time. Use a soft cloth.
Oil from skin may damage lamp. -
Do not operate the fixture fitting with a missing or damaged shield.
WARNING – Risk of Electric Shock
- May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
- A fixture shall not use tungsten halogen lamps unless the fixture is marked for such lamps.
- Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.
LOW-VOLTAGE CABLE SHALL:
- Be protected by routing in close proximity to the fixture or fitting, or next to a building structure such as a house or deck.
- Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
- Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, fixture, or fitting.
fxl.com/support
These products contain a light source of energy efficiency class G.
- MO, PO, CN, and VO
- CG – None
CE Certified: PO and MO Only
UL Listed: PO, MO, CN, and CG Only
ETL Listed: VO Only
LANDSCAPE & ARCHITECTURAL LIGHTING
Learn more. Visit fxl.com