FXLuminaire CN-51 Wall Light Instruction Manual

June 14, 2024
FXLuminaire

FXLuminaire logo

DESIGNER/STANDARD

WALL LIGHT | PO, MO, VO*, CG, CN

INSTALLATION

FXLuminaire CN-51 Wall Light - Parts 1

  1. Use provided conduit, and trim length if necessary.

  2. Install conduit sleeve into wall during construction.
    Run fixture wiring through sleeve. *Coupling for VO fixture only.

  3. Use voltmeter to ensure 11 to 15 V at fixture.

  4. Connect wiring with waterproof connector.

  5. Press faceplate into sleeve. Level and orient fixture as desired.

*For concrete ground-mount option, use construction housing.

CIRCUITING GUIDELINES

http://fxl.com/support

FXLuminaire CN-51 Wall Light - CIRCUITING

LANDSCAPE & ARCHITECTURAL LIGHTING | Learn more. Visit fxl.com

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

FXLuminaire CN-51 Wall Light - Parts 2

Please read and keep all safety and use instructions. If you have questions, contact your local distributor or visit the online support section at fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.

  • Lamp gets HOT quickly. Contact only switch/plug when turning on.

  • Do not touch hot lens, guard, or enclosure.

  • Keep lamp away from materials that may burn.

  • Do not touch the lamp at any time. Use a soft cloth.
    Oil from skin may damage lamp.

  • Do not operate the fixture fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • May be installed less than 5′ (1.5 m) from a pool, spa, or fountain when used with a UL 379 listed transformer.
  • A fixture shall not use tungsten halogen lamps unless the fixture is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW-VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the fixture or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6″ (152 mm) in order to connect to the main low-voltage cable.
  • Have the length cut off so that it is connected to a connector within 6″ (152 mm) from a building structure, fixture, or fitting.

fxl.com/support
These products contain a light source of energy efficiency class G.

  • MO, PO, CN, and VO
  • CG – None

FXLuminaire CN-51 Wall Light - icon 2

CE Certified: PO and MO Only
UL Listed: PO, MO, CN, and CG Only
ETL Listed: VO OnlyFXLuminaire logo

LANDSCAPE & ARCHITECTURAL LIGHTING
Learn more. Visit fxl.com