FXLuminaire In-Grade Light FC, RP, Kit Installation Guide

June 8, 2024
FXLuminaire

FX-Luminaire-In-Grade-Light-FC-RP-Kit-LOGO

FXLuminaire In-Grade Light FC, RP, Kit

FX-Luminaire-In-Grade-Light-FC-RP-Kit-PRODUCT-IMAGE

DESIGNER/STANDARD | IN-GRADE LIGHT | FC, RP, KT

INSTALL
  1. Change beam angle lens and color filter by removing and replacing existing components (optional).
  2. Dig hole and insert construction sleeve. Use drainage material below sleeve. Fill soil or concrete to top of sleeve cover (if applicable).
  3. Use voltmeter to ensure 11-15 V at fixture.
  4. Connect wiring with waterproof connector.
  5. Install tamper-resistant screws (optional).
  6. Replace faceplate and screws.

CIRCUITING GUIDELINES

TRANSFORMERS

Single transformer: When using one transformer, center the transformer on the wattage load. Minimize all cable runs to reduce voltage drop.
Multiple transformers: When using multiple transformers, spread the load evenly across all transformers. Avoid voltage drop by installing the transformers as close to the fixtures as possible.

Please read and keep all safety and use instructions.
If you have questions, contact your local distributor or visit the online support section at https://www.fxl.com/support.

WARNING – To reduce the risk of FIRE OR INJURY TO PERSON:

  • Turn off/unplug and allow to cool before replacing lamp.
  • Lamp gets HOT quickly. Contact only switch/plug when turning on.
  • Do not touch hot lens, guard, or enclosure.
  • Keep lamp away from materials that may burn.
  • Do not touch the lamp at any time. Use a soft cloth. Oil from skin may damage lamp.
  • Do not operate the luminaire fitting with a missing or damaged shield.

WARNING – Risk of Electric Shock

  • Install all luminaires 10 feet (3.0 m) or more from a pool, spa, or fountain.
  • A luminaire shall not use tungsten halogen lamps unless the luminaire is marked for such lamps.
  • Supply connection and electrical components are located above ground level, except for secondary cord that is suitable for wet locations.

LOW VOLTAGE CABLE SHALL:

  • Be protected by routing in close proximity to the luminaire or fitting, or next to a building structure such as a house or deck.
  • Not be buried except for a maximum 6 feet (1.8 m) in order to connect to the main low voltage cable.
  • Have the length cut off so that it is connected to a connector within 6 feet (1.8 m) from a building structure, a luminaire, or fitting.

CE Certified In-Grade Lights: FC and RP Only
UL Listed: FC and RP Only
ETL Listed: KT Only

References

Read User Manual Online (PDF format)