E E ELEKTRONIK EE820 CO Sensor for Demanding User Guide
- June 3, 2024
- E E ELEKTRONIK
Table of Contents
E E ELEKTRONIK EE820 CO Sensor for Demanding User Guide
The EE820 CO2 sensor is optimized for use in harsh, demanding applications, such as hatchers, incubators, life stock barns or greenhouses.
Outstanding Accuracy
A multiple point CO2 and temperature factory adjustment procedure leads to excellent CO2 measurement accuracy over the entire temperature working range, so the EE820 can even be installed outdoors.
Long-term Stability
The EE820 incorporates the E+E dual wavelength NDIR CO2 sensor, which compensates for ageing effects, is highly insensitive to pollution and offers outstanding long term stability.
High Resistance to Pollution
With its robust, functional IP54 enclosure with a special filter the EE820 can be employed even in harsh environment.
Fast Response Time
The fast response time version of EE820 is fitted with a forced air circulation module installed behind the filter.
Analogue and Digital Outputs
The CO2 measured data range up to 10 000 ppm is available on the analogue output (voltage / current) or on the RS485 interface with Modbus RTU or BACnet MS/TP protocol.
Easy Configuration and Adjustment
An optional adapter and the free EE-PCS Product Configuration Software facilitate the configuration and adjustment of the EE820.
Features
Technical Data
Measured values
Measuring principle| dual wavelength non-dispersive infrared technology (NDIR)
Measurement range| 0…2 000 / 5 000 / 10 000 ppm
Accuracy at 25 °C (77 °F) and 1 013 mbar (14.7 psi)| 0…2 000 ppm: < ± (50 ppm
+2 % of mv)
0…5 000 ppm: < ± (50 ppm +3 % of mv)
0…10 000 ppm: < ± (100 ppm +5 % of mv)
mv = measured value
Response time t63, typ.| 300 s (standard) 140 s (fast, with forced air
circulation module)
Temperature dependency| typ. ± (1 + CO2 concentration [ppm] / 1 000) ppm/°C
(-20…45 °C) (-4…113 °F)
Sample rate| approx. 15 s
Output
Analogue|
0…2 000 / 5 000 / 10 000 ppm| 0-5 / 0-10 V -1mA < IL < 1 mA 4-20 mA RL < 500
Ohm RL= load resistance
Digital Interface
Protocol| RS485 EE820 = 1/10 unit load
Modbus RTU or BACnet MS/TP
General
Supply voltage| 24 V AC ±20% 15 – 35 V DC
Current consumption, typ.| 15 mA + output current, for standard response time
60 mA + output current, for fast response time
Current peak, max.| 350 mA for 0.3 s (analogue output) 150 mA for 0.3 s
(RS-485 interface)
Warm up time 1)| < 5 min
Enclosure material| Polycarbonate, UL94V-0 approved
Protection class| IP54
Electrical connection| Screw terminals 2.5 mm² or M12 plug
Electromagnetic compatibility| EN61326-1 EN61326-2-3 Industrial Environment
FCC Part 15 ICES-003 ClassB
Working conditions| -20…60 °C (-4…140 °F) 0…100 % RH (non-condensing)
Storage conditions| -20…60 °C (-4…140 °F) 0…95 % RH (non-condensing)
Dimensions (mm/inch)
Ordering Guide
- Factory setting: Even Parity, Stopbits 1; Modbus Map and communication setting: See User Guide and Modbus Application Note at www.epluse.com/ee820.
- Factory setting: No Parity, Stopbits 1; Product Implementation Conformance Statement (PICS) available at www.epluse.com/ee820.
- Only for BACnet MS/TP.
Order Example
EE820-H1A3E9
- CO2 range: 0…2 000 ppm
- Output: 0-10 V
- Electrical connection: M12 plug
- Response time: standard
EE820-HV2J3E1AM4P1BD6
- CO2 range: 0…5 000 ppm
- Output: RS485
- Electrical connection: M16 cable gland
- Respnse time: fast
- Protocol: Modbus RTU
- Baud rate: 19 200
Accessories (see data sheet „Accessories“)
USB configuration adapter | HA011066 |
---|---|
Product configuration software | EE-PCS (free download: |
www.epluse.com/EE820)
Mating M12x1 connector for self assembly| HA010707
Connection cable M12x1 socket – flying leads
– 1.5 m (3.3ft)| HA010819
– 5 m (16.4 ft)| HA010820
– 10 m (32.8 ft)| HA010821
Protective cap for female M12 connectors| HA010781
Protective cap for male M12 connectors| HA010782
Power supply adapter| V03