KNOP PU901 Blower Connector User Manual

June 3, 2024
KNOP

User manual
PU901

KNOP PU901 Blower Connector

Warnings and safety instructions

  • The battery in this product must compile with the relevant IEC safety standards for batteries.
  • Do not consume or eat the battery as there is a risk of chemical burns.
  • Keep new and used batteries away from children.
  • If the battery compartment cannot be closed properly, discard the product and keep it away from children.
  • Read the intended use before using.

Intended use

The product is designed to activate a KNOP 900 series wireless receiver when a user presses the button.
PU901 can be used when the user cannot activate an alarm with a pull cord or push button.
PU901 must be coded into the receiver and the receiver must be switched on for the system to work.
Pay attention to the range as described in the section “Checking the coverage area”.

Testing and commissioning

After installation, it is important that the user tests the product by blowing against the propeller.
Staff should receive an alarm to their alarm system/receiver.
Refer to the instruction manual of the receivers used.

Check the coverage area

One person activates PU901 (as described above), while another person systematically walks around the area and makes a sketch of the building and the area where there is coverage. The sketch is placed in the office so that everyone who needs to use the system can see where there is coverage. Outside the coverage area, alarms cannot be received.
The coverage area can be increased by using a repeater system from KNOP Elektronik.
Contact your retailer for more information.

Location

PU901 should be positioned so that the user can easily blow straight into the propeller.
The push contact can be mounted on e.g. a gooseneck, contact your retailer for more information.

Service

When the user blows hard enough on the propeller to activate PU901, it will flash a green light.
The receiver will give an acknowledgement, after which PU901 will glow steady green, indicating that the transmission was successful.
If the transmission fails, PU901 repeats the transmission up to 2 times at 30 second intervals.

Battery alarm

If the battery in PU901 is low, the receiver will display “Low battery” when an alarm is received from PU901.

Changing the battery

The top and bottom of the PU901 can be unscrewed without tools.

KNOP PU901 Blower Connector - Fig 1

After replacing the battery, check PU901 as described under “Testing and commissioning”.
It takes about 1 minute after battery replacement before it can be activated.

Main menu
Use the head

Cleaning

The product can be cleaned with a moist cloth or tissue.
The propeller can be gently pulled out with pliers or other tools and cleaned.
The product is then thoroughly tested.
If necessary, the propeller can be replaced with a new one. See section “Accessories”.

Spare parts and accessories

Spare parts and accessories can be ordered from Knop Elektronik A/S at www.knop.dk.

Technical data

Frequency HF:
Range:| 869.2125 MHz
Up to 500 m of unobstructed view to an RX901B(1)
---|---
Battery type:| CR2477, lithium 3V 950 mAh
(PU900/901 before serial number 57024 used CR2354)
Battery life (expected):| Up to 5 years with 5 activations per day. (2)
Low battery alarm:| At approx. 1/3 of residual capacity
Surrounding environment:
Ambient temperature:| Indoor use. ≤ 90% non-condensing 0°C to +40°C
Cabinet type:
Cabinet dimensions:| White polyoxymethylene
Ø: 43mm L: 106mm
Density:| IP65
Connections:| None, wireless communication.
Weight:| 115g

The right to make changes is reserved.
All rights reserved.
© KNOP Elektronik A/S

(1) Measured outdoors with unobstructed view between transmitter and receiver. In buildings the range is reduced.
(2) Expected battery life depends on usage and battery brand.

Explanation of symbols and approvals


| This product complies with:
Directive 2017/745/EU MDR
Directive 1907/2006/EU REACH
Directive 2011/65/EU RoHS
ISO 14971:2019 Risk Management for Medical devices
EN 301 498-1 V2.2.3 Electro Magnetic Compatibility
EN 301 489-3 V3.1.1 Electro Magnetic Compatibility
EN 50130-4:2011 + 2014 Immunity alarm systems
EN 300 220-1 V3.1.1 Short Range Devices
EN 300 220-2 V3.1.1 Short Range Devices
EN 300 220-3 V2.1.1 Short Range Devices
EN 60601-1-2:2014 + 2015 Electromagnetic compatibility (Medical)
EN 62368-1:2020 Electrical safety
EN 50581:2012 Hazardous substances
---|---
| The product must not be used if the packaging is damaged.

**MD**

| Medical Device Class 1
| Manufacturer
KNOP Elektronik A/S, Fabriksvej 20, DK-7600 Struer, Denmark


| Read the manual(s) before installation and commissioning.
| Interference may occur in an environment with equipment marked with this symbol.
| Must be protected against liquids.
| 0 °C to +40 °C, temperature limit for transport/storage and use.
| The product must not be disposed of with normal household waste.

**SRN**

| Single Registration Number DK-MF-000025631

**UDI**

| Unique Device Identifier
PU901: 05744002850403
PU901P: 05744002850380

**REF**

| Product reference
PU901: Blow switch
PU901 P: Blow switch with position

**SN**

| Serial number Placed on the product

**IP**

| Ingress Protection Code IP40

© KNOP Elektronik A/S
Fabriksvej 20
DK-7600 Struer
knop@knop.dk
knop.dk
+45 97840444

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>