Introduction
This series LED controllers are designed to drive constant voltage LED products in voltage range of DC6- 24V. They can be controlled by the Umi compatible remote controllers and Smartphone app (-A version). With advanced BLE mesh technology, controllers can work synchronously with a robust connection. For option, IP68 waterproof feature is available on -S version, and timing play function is available on -T version.
Function & Size
1. Power supply input
The controller supply voltage range is from DC 6V to 24V. The red power cable
should be connected to power positive and black to negative. (For other cable
color, please refer to the labels). The LED output voltage is at same level as
the power voltage, please make sure the power supply voltage is correct and
the power rating is capable for the load.
2. LED output
Connect constant voltage LED loads to these cables.
Please make sure the LED rated voltage is same as the power supply and each
channel’s maximum load current is in range of the controller rated current.
Please refer to following output wiring diagram for different models:
Single color: red cable to LED + and black to –.
Tunable white: black cable to LED , white to cool white + and yellow to warm white –. The two black cables are connected inside the controller.
RGB and RGBW: black cable to LED + , R, G, B and W cable to the relevant color –.
Model MP40-A and MP40-T can be configured to different application for single color, CCT, RGB or RGBW.
For different application, the 1-4 channel function is mapped as following table:
3. Work status indicator
This indicator shows all working status of the controller. It displays
different events as following:
Steady blue: Normal working.
Short white blink: Command received.
White blink for 3 times: Identification or confirmation.
Single yellow flash : Edge of the content.
Red flash: Overload protection.
Yellow flash: Overheat protection.
Green blink: Timing play activated.
Wiring
Please connect the controller output to LED loads and power supply to the controller power input. The power supply voltage must be same as the LED load’s rated voltage. Check all cables to be well connected and insulated before power on.
Operation
4. Pairing remote controllers
The controller can be paired with compatible Umi remote controller for operation. To pair or unpair the remote controller, user needs to connect and disconnect the power of controller and press specific combo keys on the remote controller. For detailed method, please refer to the remote controller’s user’s manual. Each controller can be paired up to total 5 remote controllers.
5. Control by smartphone
For -A & -T version controller, besides Umi wireless remote controllers, it can also be controlled by Umi Smart app. User can operate the controller from remote and/or Umi Smart app. The status and group/scene features will be synchronized from remote controller and App. Please search and download ‘Umi Smart’ app from Apple app store or Google play market to setup. There will also be a QR code on the controller for app download link.
Advanced features
6. Change model function (MP40 only)
MP40-A and MP40-T controller’s function can be changed from 1 channel (single
color) to 4 channels (RGB+White) by Umi Smart app.
To change the model function, please use the Umi Smart app and detect factory default devices in ‘Discover nearby’ function and then tap the item icon and select ‘change function’ menu to proceed.
7. Waterproof (-S version)
The IP-68 waterproof feature with glue injection finish is available on -S version controllers. For overall waterproof performance, the cables must be waterproof treated separately.
Wireless signal degrade : The wireless communication ability could degrade when using at wet environment, please be aware that the wireless control distance will be shortened in such case.
8. Force turning on
The controller will restore to the last on/off status on each power on. To force turn on the controller at OFF status, user need to connect and disconnect the power of the controller for 3 times in a short time. After this operation, the controller will be rest to ON status.
9. Timing play with backup battery (-T version only)
A real time clock with backup battery is equipped with the -T version model.
With this feature, user can setup timing play function with multiple repeating
features of weekday or date on the Umi Smart app.
The real time clock runs by itself and will correct time once connected to the smartphone app. The builtin backup battery will reserve the timing play setting up to 48 hours after power cut. The saved timing play function will be invalid after the backup battery runs out and it will automatically recover once being connected to smartphone again.
10. Change PWM frequency to avoid noise and flicker
In some LED application, noise or flicker issue may occur at the default or
low PWM frequency. The controller’s PWM frequency can be changed via the Umi
Smart app. The frequency must be tuned with LED type and installation. To
maintain more stable working and less power loss, please do not set to high
frequency if no noise or flicker issues occurred.
To change the PWM frequency, please use the Umi Smart app and detect factory default devices in ‘Discover nearby’ function and then tap the item icon and select ‘change setting’ menu to proceed.
CAUTION: The controller’s efficiency will drop versus increased frequency and the output current.
11. Protection function
The controller has full protection function against wrong wiring, load short circuit, overload and overheat. The controller will stop working and the indicator will flash with red / yellow color to indicate the malfunction.
The controller will try to recover from protection status in a short time when the working condition is good.
For protection issues, please check the situation with different indicator information:
Red flash: Check the output cables and load, make sure no short circuit and the load current is in rated range. Also the load must be constant voltage type.
Yellow flash: Check the installation environment, make sure in a rated temperature range and with good ventilation or heat dissipation condition.
Specification