Rayrun N40 RGB+W LED Controller User Manual

June 3, 2024
RayRun

Rayrun-N40-RGB-W-LED-Controller-LOGO

RayrunN40 RGB+W LED Controller

features

Introduction

N40 RGB+W LED controller is designed to drive constant voltage LED products with common anode connection in voltage range of DC5-24V. The main unit works with a RF remote controller, user can setup white LED brightness, RGB LED color, brightness and dynamic modes on the remote controller, the main unit is powered by DC power supply and receives remote controller commands to drive LED fixtures.

Dimension

Rayrun-N40-RGB-W-LED-Controller-FIG-1

Wiring & Indicator

Power supply input

Install positive power cable into the terminal marked with ‘+’ and negative power cable into the terminal marked with ‘-’. The controller can accept DC power from 5V to 24V, the output voltage is the same as the power supply, so please make sure the LED rated voltage is same as the power supply.

LED output

Connect LED fixtures to this terminal. Install LED common anode cable into the terminal marked with ‘+’ and each channel LED cables into the terminal marked with R, G, B and W. Please make sure the LED rated voltage is same as the power supply and each channel’s maximum load current is below the controller rated current.
The controller will run into protection if the output been overloaded or short circuited. The indicator will flash red color and stop working in this case, Please check the wiring and load current to remove the fault.

Work status indicator

This indicator shows the working statuses of the controller. It displays different events as follows:

  • Steady green: Normal working.
  • Single green blink: Command received.
  • Long single green blink: Mode or color cycle edge. Long single yellow blink: Brightness or speed limit. Red flash: Overload protection.
  • Yellow flash: Overheat protection.
  • Green flash 3 times: New remote controller paired.

Functions

Turn ON / OFF

Press the ‘I’ key to turn on the unit or press the‘ O’ key to turn it off. The main unit will memorize the on/off status and will restore to the previous status on next power on. Please use remote controller to turn on the unit if it was switched to off status before power cut.

Light mode switch

Press this key to switch between RGB, white and RGB+White mode. In RGB mode, white channel will be disabled; In white mode, RGB channel will be disabled; In RGB+White mode, all channels are usable.

Select static RGB color

Press and key to select the color from the preset library colors.

Shortcut color select

Shortcut key to static colors. LED will run the relevant color when pressing the specific color key. The shortcut color is included in the ‘COLOR+’ and ‘COLOR-’ content.

White brightness control

Press the key to increase the white LED brightness and press the key to decrease it.

RGB brightness control

Press the key to increase press RGB LED brightness and the key to decrease it.

RGB dynamic effect

These keys control the RGB dynamic effects. Press and effect o select dynamic effects, and press any key to set the running speed of the dynamic effects.

Remote indicator

This indicator blinks when remote controller is working. If the indicator flash slowly when pressing keys, it means the remote battery is nearly empty and please change the battery in this case. The battery model is CR2032.

Operation

Using the remote controller

Please pull out the battery insulating tape before using. The RF wireless remote signal can pass through some nonmetal barrier. For proper receiving remote signal, please do not install the controller in closed metal parts.

Pair a new remote controller

The remote controller and main unit are 1-to-1 paired as factory default. It’s possible to pair a maximum 5

remote controllers to one main unit and each remote controller could be paired to any main unit.
User could pair a new remote controller to main unit by following two steps:

  1. Plug off the power of main unit and plug in again after more than 5 seconds.
  2. Press and keys simultaneously for about
  3. seconds, within time of 10 seconds after the main unit powered on.

Keep current remote only

In some cases, one main unit might be paired with
several remote controllers but extra remote controllers are no longer needed. User could simply pair the current using remote to main unit again, then the main unit will dis-pair all other remote controllers and recognize current one only.

Protection

The main unit has full protection function for wrong wiring, output short circuit, overload and overheat. The controller will protect itself from damage at these extreme conditions and could automatically recover when working condition is good. To avoid the protection, please ensure the LED fixtures are capable for constant voltage driving and in rated range, the cables are well connected and insulated. Also please install the controller with good ventilation and heat dissipation condition.

Specification

Model N40
Dynamic mode 34 modes
Static color 30 colors
PWM grade 4000 steps
White brightness grade 10 levels
Color brightness grade 5 levels
Speed grade 10 levels
Direct color select 7 direct keys
Overload protection Yes
Overheat protection Yes
Working voltage DC 5-24V
Remote frequency 433.92MHz
Remote control distance >15m at open area
Rated output current 4x3A
Controller dimension 87x24x15mm

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>