Labnet S2025-B ProBlot Rocker 25 and 25XL High Capacity Bench Rocker Instruction Manual

June 3, 2024
Labnet

Labnet S2025-B ProBlot Rocker 25 and 25XL High Capacity Bench Rocker

Labnet-S2025-B-ProBlot-Rocker-25-and-25XL-High-Capacity-Bench-Rocker-
product

Introduction

Congratulations on purchasing your Labnet ProBlot™ Rocker. This high-capacity bench rocker is a basic bench-rocking platform that has been designed for a long life and trouble-free service. The bench rocker speed is adjustable to provide the gentle motion required for staining fragile gels as well as the more vigorous action necessary for washing blots.

Packing

The Labnet ProBlot Rocker includes the following components:

  • S2025-B ProBlot Rocker with single platform
  • S2025-D-B ProBlot Rocker with double platform
  • S2025-XL-B ProBlot Rocker with large single platform
  • S2025-XLD-B ProBlot Rocker with large double platform

Instruction manual

Specifications

  • Electrical requirements Rocker 115V: 120V± 10% – 50/60Hz, 0.2A
  • Rocker 230V: 230V± 10% – 50/60Hz, 0.1A
  • Fuse 2 x 1A (120V) 2 x 0.5A (230V)
  • Speed settings 5 – 120 tilts/minute
  • Motion Rocking
  • Tilt range Fixed 7°
  • Timer from 0 to 2 hrs. or continuous
  • Maximum load 11 lbs. (5 kg)
  • Dimensions Rocker 25: 11.4 x 12.6 x 5.7 in. (29 x 32 x 14.5 cm)
  • Rocker 25 XL: 12.8 x 14.2 5.7 in. (32.5 x 36 x 14.5 cm)
  • Platform dimensions 11.4 x 8 in. (28.9 x 20.3 cm)
  • Weight 11.7 lbs. (5.6 kg)
  • Operating conditions from 4°C to 65°C, up to 85 RH, non-condensing

Safety Information

Do not use the rocker near water. Ensure that water doesn’t get on the device, particularly during cleaning.

  • If the unit is used in a manner not specified by the manual, the degree of protection may be impaired.
  • The plug should only be used in a wall outlet with protective earthing.
  • The unit should be used with a power supply cord of at least 18 AWG.
  • The equipment will not restart if mains power is interrupted.
  • The equipment will restart in cases of mechanical interruption.
  • Do not expose the rocker to aggressive vapors (e.g. organic solvents).
  • Do not insert any objects into the rocker (such as a screwdriver or metal rods).
  • Never operate the rocker without the platform securely attached.
  • Hazardous samples should be shaken only in appropriate containment vessels.
  • Do not put your fingers between the rocking platform and the housing. Danger of mechanical injury.

Installation

Device Placement

  • When selecting the right place for the device, consider the following

  • Place the device on a smooth, horizontal and stable surface.

  • Leave enough space around the device for normal air circulation, min. 10 cm.

  • Leave enough space around the device, for easy access and maintenance.

  • Avoid locations subject to shocks and vibrations.

  • Avoid locations subject to frequent power fluctuations or power losses, as this may affect shaker performance.

  • Attaching the Power Cord

  • First, connect the main power cord to the shaker then connect the plug into a grounded wall socket. Avoid sockets where powerful electric motors, refrigerators and similar devices are also connected.

  • Be careful when you plug the cord into the grounded wall socket.

  • Do not touch the plug with wet hands.

  • Do not pull the plug by the cord.

Installation of Double Stacking Platform

  1. Set posts (A) through the four holes at the corners of the bottom platform.
  2. Add a washer (B) and nut (C) to each post.
  3. Fit the upper platform (D) onto the top of the four posts through the corner holes.
  4. Screw on the four metal knurl nuts (E) to secure the upper platform.

Operating Instructions

Control Panel

  1. POWER switch – to turn the rocker ON (power switch illuminates) or OFF.
  2. SPEED controller – to set the shaker speed.
  3. TIME controller – to set the timer.
  4. RUN – green light illuminates when the shaker is operating.
  5. START/STOP button – to START or STOP the shaking operation.
  6. HOLD function – the yellow light illuminates and the shaker operates continuously.

Basic Operation

  1. Switch on POWER.
  2. Set the SPEED to the desired value.
  3. Set the TIME to the desired value or to HOLD (the shaker will operate continuously and the yellow light will illuminate).
  4. Press the START/STOP button to start rocking.
  5. Press the START/STOP button to stop rocking when in the HOLD position. The device will automatically stop after the set time when using the timer.

NOTE: Pressing the START/STOP button during timed operation will reset the timer.

Troubleshooting

Should you have a question about the Labnet ProBlot™ Rocker 25 and 25XL or require service for the unit, contact Corning Customer service at 800.492.1110 or 978.442.2200. Do not send the unit for service without first calling to obtain a repair authorization (RA) number. The unit should be properly packed to avoid damage. Any damage resulting from improper packaging shall be the responsibility of the user.

  • Problem Explanation/Solution
  • The POWER switch doesn’t illuminate when turned ON
  • Check the connection to the main power supply
  • Check fuses
  • Call authorized service
  • Rocker doesn’t start when you press
  • START/STOP key
  • Check the connection to main power supply
  • Check fuses
  • Call authorized service

Maintenance and Cleaning

  • No routine maintenance or lubrication is required.
  • It is recommended that the rocker is kept clean to ensure long trouble-free operation.

Cleaning

Prior to any cleaning or maintenance of the device, unplug the power cord from the wall socket.
The outside housing can be cleaned with a soft, damp cloth when needed. Do not use any aggressive or abrasive cleaners (acetone, nitro, polish etc.) This may permanently damage the rocker finish.

Limited Warranty

Corning Incorporated (Corning) warrants that this product will be free from defects in material
and workmanship for a period of one (1) year from date of purchase. CORNING DISCLAIMS ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. Corning’s sole obligation shall be
to repair or replace, at its option, any product or part thereof that proves defective in material or workmanship within the warranty period, provided the purchaser notifies Corning of any such defect. Corning is not liable for any incidental or consequential damages, commercial loss or any other damages from the use of this product. This warranty is valid only if the product is used for its intended purpose and within the guidelines specified in the supplied instruction manual. This warranty does not cover damage caused by accident, neglect, misuse, improper service, natural forces or other causes not arising from defects in original material or workmanship. This warranty does not cover motor brushes, fuses, light bulbs, batteries or damage to paint or finish. Claims for transit damage should be filed with the transportation carrier. In the event this product fails within the specified period of time because of a defect in material or workmanship, contact Corning Customer Service at: USA/Canada 1.800.492.1110, outside the U.S. +1.978.442.2200, visit www.corning.com/lifesciences or contact your local support office. Corning’s Customer Service team will help arrange local service where available or coordinate a return authorization number and shipping instructions. Products received without proper authorization will be returned. All items returned for service should be sent postage prepaid in the original packaging or other suitable carton, padded to avoid damage. Corning will not be responsible for damage incurred by improper packaging. Corning may elect for onsite service for larger equipment. Some states do not allow limitation on the length of implied warranties or the exclusion or limitation of incidental or consequential damages. This warranty gives you specific legal rights. You may have other rights which vary from state to state. No individual may accept for, or on behalf of Corning, any other obligation of liability, or extend the period of this warranty. For your reference, make a note of the serial and model number, date of purchase, and supplier here.

Serial No. __ Model No. _____

Date Purchased _ Supplier ___

Equipment Disposal

According to Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE), this product is marked with the crossed-out wheeled bin and must not be disposed of with domestic waste. Consequently, the buyer shall follow the instructions for reuse and recycling of waste electronic and electrical equipment (WEEE) provided with the products and available at www.corning.com/weee. To request certificates, please contact us at www.labnetlink.com.
Warranty/Disclaimer: Unless otherwise specified, all products are for research use or general laboratory use only.

  • Not intended for use in diagnostic or therapeutic procedures. Not for use in humans.

  • These products are not intended to mitigate the presence of microorganisms on surfaces or in the environment, where such organisms can be deleterious to humans or the environment. Corning

  • Life Sciences makes no claims regarding the performance of these products for clinical or diagnostic applications.

  • For a listing of US medical devices, regulatory classifications or specific information on claims, visit www.corning.com/resources.

  • Corning Incorporated
    Life Sciences

  • www.corning.com/lifesciences

  • NORTH AMERICA t 800.492.1110 t 978.442.2200

  • ASIA/PACIFIC

  • Australia/New Zealand t 61 427286832

  • Chinese Mainland t 86 21 3338 4338

  • India t 91 124 4604000

  • Japan t 81 3-3586 1996

  • Korea t 82 2-796-9500

  • Singapore t 65 6572-9740

  • Taiwan t 886 2-2716-0338

  • EUROPE

  • CSEurope@corning.com

  • LATIN AMERICA

  • grupoLA@corning.com

  • Brazil t 55 (11) 3089-7400

  • Mexico t (52-81) 8158-8400

  • For a listing of trademarks, visit www.corning.com/clstrademarks. All other trademarks are the property of their respective owners.

  • © 2021 Corning Incorporated. All rights reserved. 12/21 CLSLN-AN-1021DOC REV1

  • www.labnetlink.com

Documents / Resources

| Labnet S2025-B ProBlot Rocker 25 and 25XL High Capacity Bench Rocker [pdf] Instruction Manual
S2025-B, ProBlot Rocker 25 and 25XL High Capacity Bench Rocker, S2025-B ProBlot Rocker 25 and 25XL High Capacity Bench Rocker, Rocker 25 and 25XL High Capacity Bench Rocker, 25XL High Capacity Bench Rocker, High Capacity Bench Rocker, Capacity Bench Rocker, Bench Rocker, Rocker
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals