DEATSCH DW65c Fuel Pump Installation Guide

June 3, 2024
DEATSCH

DW65c Fuel Pump
Installation GuideDEATSCH DW65c Fuel Pump

Parts List:

  • DW65c/300c, 9-651/9-307
  • Fuel Sock
  • 3-116 O-Rings (x2)
  • Fuel Sock Retainer Clip
  • Super Lube

DeatschWerks

06-11 Civic DW65c/300c Fuel Pump Installation Guide
06-11 Civic DW Fuel Pump Install
PLEASE READ – this guide is intended to aid in the installation of our products. It is recommended that factory manuals or instructions are followed to remove the fuel  pump assembly from the vehicle. Some instructions in this guide are generic. The factory manual should supersede any contradiction.
Below is a picture of suggested tools that will make the installation process easier.DEATSCH DW65c Fuel Pump - Figure 1

  1. disconnect the connector for the fuel level sender (green) and feed for the venturi system (black) and depress the tabs (green) to separate the bucket from the assembly
    DEATSCH DW65c Fuel Pump - Figure 2DEATSCH DW65c
Fuel Pump - Figure 3

  2. remove the fuel pump retainer by slipping a flat-head screwdriver under the 3 using a twisting motion and pull the fuel pump out of the assembly
    DEATSCH DW65c Fuel Pump - Figure 4

  3. remove these parts from the fuel pump, they will be installed on the DW65c
    DEATSCH DW65c Fuel Pump - Figure 5

  4. prep the DW65c using both o-rings supplied in the kit on the pump outlet and the OE outlet spacer
    DEATSCH DW65c Fuel Pump - Figure 6DEATSCH DW65c
Fuel Pump - Figure 7

  5. install DW65c into the pump assembly while connecting the electrical connector and snapping the pump retainer in place
    DEATSCH DW65c Fuel Pump - Figure 8

  6. install the assembly into the bucket and reconnect the venturi lead
    DEATSCH DW65c Fuel Pump - Figure 9

  7. reinstall the assembly into the fuel tank and attach a length of hose to the outlet of the pump assembly allowing it to drain into a fuel safe container and prime the fuel  pump assembly

  8. crank the engine for a period of time long enough to prime the pump assembly and evacuate the air introduced during the pump installation process

  9. attach supply line to the outlet of the pump assembly