TEKBOX TBCCP1-400K600 Coaxial RF Current Monitoring Probe User Manual

June 3, 2024
TEKBOX

TEKBOX TBCCP1-400K600 Coaxial RF Current Monitoring Probe User Manual
TEKBOX TBCCP1-400K600 Coaxial RF Current Monitoring
Probe

Introduction

The TBCCP1-400K600 is a coaxial RF current monitoring probe, expanding the Tekbox product range of affordable EMC pre-compliance test equipment.
The probe has a 3 dB bandwidth from 400 kHz to 600 MHz and a very flat response from 1 MHz  o 200 MHz. The transimpedance is characterized over the frequency range from  10 Hzto 100 MHz. The TBCCP1-400K600 is primarily designed as transducer for passive loop antennas or for measurement of RF currents in coaxial cables.
Product Overview
Picture 1: TBCCP1-3K100 RF current monitoring probe

The probe is equipped with N-connectors. An attachment with a ¼” thread permits connectivity to standard tripods.

Specification

  • Characterized frequency range: 10 Hz to 600 MHz
  • Transfer impedance: 23 dB Ohm
  • 3 dB bandwidth: 400 kHz to 600 MHz, typ.
  • Dimensions: 76 mm x 102 x 69 mm
  • Weight: 400 g
  • Connector type: N female
  • Max. primary current (RF): 12 A
  • Max. core temperature: 125 °C

Transfer impedance

Transfer impedance
Figure 1: transfer impedance, 10 Hz – 1 GHz, typical data

Coaxial Path – Insertion loss (S21)

Coaxial Path
Figure 2: S21, insertion loss of the coaxial path, 10 Hz – 1 GHz, typical data

Coaxial Path – Matching (S11)

Coaxial Path Graph
Figure 3: S11, impedance matching of the coaxial path, 10 Hz – 1 GHz, typical data

Application

The TBCCP1-400K600 is primarily designed as current transducer for passive loop antennas. It will provide a low antenna factor / good sensitivity over a wide frequency range.

Combined with a 185 cm length slotted coaxial cable, it will form a passive loop antenna with a diameter of 60 cm. The magnetic antenna factor will have a value of approximately -18 dBS/m.

When used as transducer for a passive antenna, a typical sensitivity of -22 dBµA/m can be achieved. This is sufficient for all CISPR xx radiated emission measurments in the frequency range from 9 kHz to 30 MHz.

For more details, download the application note Loop Antenna Basics.pdf from the Tekbox website.

Typical transfer impedance table

The table below shows typical transfer impedance data of a TBCCP1-400K600 current probe. Each current probe is delivered with its corresponding measurement protocol. This data can be used for the creation of a correction file for EMCview or similar EMC measurement software.
The transfer impedance in dBΩ subtracted from the analyzer reading in dBµV gives the corrected reading in dBµA. Refer to the application notes of EMCview on how to create a current probe correction file, download a file with typical data from the Tekbox website or simply select the file from the installed correction file directory.

Frequency [MHz]| transfer impedance [dBΩ]| Frequency [MHz]| transfer impedance [dBΩ]
---|---|---|---
0.00001| -62.56| 1| 22.57
0.000025| -58.21| 2.5| 22.74
0.00005| -56.10| 5| 22.82
0.000075| -50.92| 7.5| 22.89
0.0001| -48.21| 10| 22.95
0.00025| -40.06| 20| 23.15
0.0005| -34.26| 30| 23.19
0.00075| -30.77| 40| 23.25
0.001| -28.20| 50| 23.26
0.00125| -26.37| 55| 23.26
0.0015| -24.76| 60| 23.25
0.00175| -23.49| 65| 23.26
0.002| -22.30| 70| 23.25
0.00225| -21.29| 75| 23.24
0.0025| -20.39| 80| 23.24
0.005| -14.34| 85| 23.25
0.0075| -10.83| 90| 23.24
0.01| -8.33| 95| 23.24
0.025| -0.39| 100| 23.24
0.05| 5.55| 200| 23.51
0.075| 8.98| 300| 24.41
0.1| 11.34| 400| 25.57
0.25| 18.04| 500| 25.70
0.5| 21.32| 550| 25.53
0.75| 22.28| 600| 25.53

Table1: Transfer impedance: 10 Hz to 600 MHz, typical data

Calibration

Tekbox coaxial RF current probes do not need a calibration fixture for the measurement of the transfer impedance.
Calibration
Figure 4: S21, transimpedance measurement set up

Calculate the transfer impedance ZT using the formula below:
ZT [dBΩ] = Pin [dBm] – Pprobe [dBm] +34 dB or simply
ZT [dBΩ] = S21 [dB] +34 dB

Ordering Information

Part Number Description
TBCCP1-400K600 RF surface current monitoring probe, beech-wood box,

calibration protocol 1kHz – 400 MHz

History

Version Date Author Changes
V 1.0 1.7.2022 Mayerhofer Creation of the preliminary document

www.tekbox.com
TekBox Digital Solutions Vietnam Pte. Ltd.
Factory 4, F4, Lot I-3B-1, Saigon Hi-Tech Park, Tan Phu Ward, District 9, Ho Chi Minh City, Vietnam

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals