Product Specifications

  • OUTDOOR UNIT

    • Voltage-Phase-Hz: 208/230-1-60

    • Minimum Circuit Ampacity: 24.4

    • Max. Over-current Protection: 40

    • COMPRESSOR:

    • RLA: 17.5

    • LRA: 27.9

    • Drive Method: Variable rotary

    • Noise-cancelling Jacket: Yes

    • Crankcase Heater: Factory installed Internal
      heating

    • OUTDOOR FAN:

    • Condenser Fan Motor Type: Propeller Brushless
      DC Motor

    • Horse Power (HP): 1/3

    • Motor Speed RPM: 930

    • CFM @ 0 in. W.G FLA: 3250

    • OUTDOOR COIL TYPE:

    • Rows: 2

    • Tube Size (in.): 9/32

    • Heating Metering Device: EEV

    • Cooling Metering Device (Indoor side):
      TXV

    • Factory Supplied Refrigerant Charge (R-410A,
      oz):
      Data on nameplate

    • Liquid Line Size (in. O.D.): 3/8

    • Suction Line Size (in. O.D.): 3/4

    • Dimensions (W X H X D): Data on nameplate

    • Net Weight (LBS): 150

    • Shipping Weight (LBS): 181

    • Max. Line Length (FT): 100

    • Max. Elevation Difference (FT): 50

Mechanical Specifications

  • Communication Method: Non-Communicating
    Inverter condensing units compatible with most 24Vac controlled
    thermostats and R-410A indoor units (TXV required)

  • Cooling/Heating Ambient Temperature Range:
    20°F to 122°F / -4°F to -20°F

  • Cooling/Heating Capacities: Matched with AHRI
    certified air handlers

Casing

The unit casing is constructed of heavy gauge, Galvanized steel
and painted with a weather-resistant powder paint on all grilles
and panels.

Refrigerant Controls

The refrigeration system controls include condenser fan,
compressor inverter drive, electronic expansion valve, and
reversing valve.

Rotary Compressor

The compressor offers flexible capacity output from 25% to 110%
and is equipped with a Noise-cancelling Jacket.

Condenser Coil

The outdoor coil provides low airflow resistance and efficient
heat transfer, protected on all four sides by grille panels.

Note:

The manufacturer reserves the right to change specifications or
designs without notice. Last updated: Jun 2023.

Frequently Asked Questions (FAQ)

1. What is the maximum ambient temperature range for this

unit?

The unit is designed to operate at outdoor ambient temperatures
as high as 122°F in cooling mode and as low as -4°F in heating
mode.

2. Is the refrigerant charge factory supplied?

Yes, the unit comes fully charged up to a 25ft line set from the
factory.

3. What type of motor does the outdoor fan have?

The outdoor fan motor type is a Propeller Brushless DC
Motor.

4. What is the maximum line length supported by the unit?

The maximum line length supported is 100 feet.

“`

TAG:
SUBMITTAL

Up to 3 Ton Inverter Split System Heat Pump
W
H D

Sound pressure level (dB)

EODA18H-2436B

2Ton *

3Ton

Standard

63

66

Silent mode

59

64

Super silent mode

56

60

  • Refer to the installation manual for capacity selection.

Product Specifications

OUTDOOR UNIT Voltage-Phase-Hz Minimum Circuit Ampacity Max. Over-current Protection COMPRESSOR RLA LRA Drive Method Noise-cancelling Jacket Crankcase Heater OUTDOOR FAN Condenser Fan Motor Type Horse Power (HP) Motor Speed RPM CFM @ 0 in. W.G FLA
OUTDOOR COIL TYPE
Rows Tube Size (in.) Heating Metering Device Cooling Metering Device (Indoor side)

EODA18H-2436BAA 208/230-1-60 24.4 40
Variable rotary 17.5 27.9
Inverter Factory installed Internal heating
Propeller Brushless DC Motor
1/3 930 3250 2.5 Copper tube with hydrophilic aluminum fins
2 9/32 EEV
TXV

Factory Supplied Refrigerant Charge (R-410A, oz)

Data on nameplate

Liquid Line Size (in. O.D.)

3/8

Suction Line Size (in. O.D.)

3/4

Dimensions (W X H X D)

29-1/8 × 24-15/16 × 291/8

Net Weight (LBS)

150

Shipping Weight (LBS)

181

Max. Line Length (FT)

100

Max. Elevation Difference (FT)

50

Manufacturer reserves the right to change specifications or designs without notice.

Jun 2023

Mechanical Specifications
Communication Method
Non-Communicating Inverter condensing units which are compatible with most 24Vac controlled thermostats and R-410A indoor units (TXV required).
General
The EODA18H-2436B is fully charged up to 25ft line set from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 122(and as low as 20) in cooling mode, and as low as -4 in heating mode. Cooling/Heating capacities are matched with air handler that are AHRI certified. The units are certified to ETL.
Casing
Unit casing is constructed of heavy gauge, Galvanized steel and painted with a weather resistant powder paint on all grilles, panels.
Refrigerant Controls
Refrigeration system controls include condenser fan, compressor inverter drive, electronic expansion valve and reversing valve.
Rotary Compressor
Flexible capacity output from 25%-110%. Compressor is equipped with Noise- cancelling Jacket.
Condenser Coil
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by grille panels.