CyberPower B602RC1GY 6 Outlet Surge Protector User Manual

September 28, 2024
CyberPower

B602RC1GY 6 Outlet Surge Protector

“`html

Specifications:

  • Model Number: B602RC1
  • Outlets: 6 Standard Outlets
  • Power Cord Length: 2 feet
  • Surge Protection: 500 Joules
  • Electrical Rating: 125 V / 15 A / 60 Hz / 1875 W
  • UL Clamping Voltage: 800 V (L-N)
  • Maximum Peak Current: 15,000 A
  • AC Lines Protected: L-N: 15,000 A
  • Response Time: Less than 1 nanosecond
  • Circuit Breaker: Resettable 15 Amp

Product Usage Instructions:

1. ON/OFF Reset Control Switch and Circuit Breaker:

The switch controls power to all outlets and acts as a 15A
breaker. In case of an overload, the surge protector will
automatically switch off. To resume operation, remove the overload
condition and reset the surge protector by switching it back
ON.

2. Standard Grounded Outlets (6):

The surge protector features six standard grounded outlets for
connecting your devices.

3. 2-ft Power Cord:

The product comes with a 2-foot power cord for convenient
placement.

4. Keyhole Mounting Slots:

Mount the surge protector easily using the keyhole mounting
slots located on the back of the unit.

FAQ:

Q: What should I do if the circuit breaker trips?

A: If the circuit breaker trips, check for any
overloaded devices connected to the surge protector. Remove the
device causing the overload, then reset the surge protector by
switching it back to ON position.

Q: How can I contact technical support for assistance?

A: For technical support, visit
CyberPowerSystems.com/support or call toll-free at
1-877-297-6937.

“`

YOUR ULTIMATE ALLY IN POWER
6-OUTLET SURGE PROTECTOR
B602RC1GY B602RC1HPK B602RC1DBL
USER MANUAL

FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15A breaker. When an overload occurs, it will automatically switch off. To resume operation, ensure the overload condition is removed and reset the surge protector by switching the unit ON.
2. Standard Grounded Outlets (6)
3. 2-ft Power Cord
4. Keyhole Mounting Slots (on back)

SPECIFICATIONS
Model Number: Outlets: Power Cord Length: Surge Protection: Electrical Rating: UL Clamping Voltage: Maximum Peak Current: AC Lines Protected: Response Time: Circuit Breaker:

B602RC1 6 Standard Outlets 2 feet 500 Joules 125 V / 15 A / 60 H / 1875 W 800 V (L-N) 15,000 A L-N: 15,000 A Less than 1 nanosecond Resettable 15 Amp

1
2
Cyber Power Systems (USA), Inc. 4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com

iWARNING: This product can expose you to chemicals including bisphenol A (BPA) and styrene (ABS), which is known to the State of California to cause reproductive harm and cancer. For more information, go to www.P65Warnings.ca.gov..

CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK: Use only in dry locations and only indoors. DO NOT plug into another relocatable power tap. DO NOT “daisy chain” surge protectors. DO NOT use with any aquarium equipment. DO NOT use if properly grounded outlets are not available. DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel. DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life, but it will maintain unprotected power to the load.

TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped. Examine your connected equipment and remove the device that is overloading the circuit. Then, turn the ON/OFF switch back to RESET.

FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding: · Product information and certifications · Product warranty · Connected equipment guarantee

TECHNICAL SUPPORT Visit: CyberPowerSystems.com/support Toll-Free: 1-877-297-6937
© 2024 Cyber Power Systems (USA), Inc. All rights reserved. All other trademarks are the property of their respective owners.

CONFORMANCE APPROVALS This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against

harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

· Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals