INTRODUCTION
The VIS-MINI-CNTRL is a mini single door control panel, can work with any entry device Wiegand 26~44, 56, 58 bits output reader. Card type depends on the reader, example: EM, HID, and MFR card types. It uses Atmel microcontroller to assure stable performance and equips with an infrared remote control for easy operation. The VIS-MINI-CNTRL supports 1,000 users; all user data can be transferred.If the VIS-MINI-CNTRL is connected to a keypad/reader you must first set the keypad into Wiegand mode for it to communicate correctly with the VIS-MINI-CNTRL (Refer to page No. 8).All programming will be done in the VIS-MINI-CNTRL but not on the keypad/reader. Is also highly suggested to change the master code in the VIS-MINI-CNTRL (Refer to page No. 7 and page No. 8 ).
Features
- 12V DC power input
- One relay, 1000 users
- Multi-access modes: Card, card or PIN, and multi cards/PINs
- Wiegand 26~44, 56, 58bits input
- Can connect with any reader with Wiegand 26~44, 56, 58bits output
- Can connect with any keypad reader with 4bits, 8bits (ASCII), or 10bits virtual number output
- User data can be transferred (except fingerprint users)
- 2 devices can be interlocked for 2 doors
- Support Master Card and Authorized User
Specifications
User Capacity | 1,000 |
---|---|
Common User | 989 |
Visitor User | 10 |
Authorized User | 1 |
Operating Voltage
Idle Current Active Current
| 12V DC
<100mA
<150mA
Wiring Connections| Relay output, exit button, Wiegand input
Relay
Adjustable Relay Output Time Lock Output Load
| One (NO, NC, Common)
0~99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand Interface| Wiegand 26~44, 56, 58bits
Operating Humidity
Environment
| Indoor
0~90%RH
Physical Dimensions
Shipping Weight Unit Weight
| ABS Shell
L65 x W54 x H19 (mm) L2.56 x W2.13 x H0.75 (in.)
40g 100g
Carton Inventory
INSTALLATION
Wiring
Name | Notes |
---|
The Left Side
LED| Green LED Light Control
D1| Wiegand Input Data 1
D0| Wiegand Input Data 0
GND| Negative Pole of DC (12V DC) Power Input
+DC| Positive Pole of DC (12V DC) Power Input
The Right Side
OPEN| Connect to One Wire of Exit Button
NO| Normally Open Relay Output (install diode provided)
GND
(COM)
| Negative Pole of Lock
(Common Connection for Relay Output)
NC| Normally Closed Relay Output (Install diode provided)
Sound and Light Indication
Operation Status | LED | Buzzer |
---|---|---|
Stand by | Red light bright | |
Enter programming mode | Red light shines | One beep |
In the programming mode | Orange light bright | One beep |
Operation error | – | Three beeps |
Exit from the programming mode | Red light bright | One beep |
Open lock | Green light bright | One beep |
Alarm | Red light shines |
quickly
| Beeps
Connection Diagram
Fail-Safe Lock (Magnetic Lock, Electric Strike, Drop
Bolt)
This connection works for all the VIS-3000 Series keypadsFail-Secure Lock
(Electric Strike or Drop Bolt) or Door/Gate Operator
This connection works for all the VIS-3000 Series keypads
Remark:
The power supply’s voltage must be the same with lock’s supply voltage, or
else, the lock will not work properly or be damaged. User Operation & Reset to
Factory Default
- Open the door: Read valid user card or input valid user PIN
- Remove Alarm: Input Master Code # or read Master Card or valid-user
- To reset to factory default & Add Master Cards: Power off, press the Exit Button (or connect “OPEN” and “GND” to be short circuit), hold it and power on, there will be two beeps, then release the exit button (or disconnect
- “OPEN” and “GND”), the LED light turns into yellow, then read any 125KHz EM card or HID card or 13.56MHz Mifare card, the LED will turn into red, means the reset to factory default was successful. Of the card reading, it is the Master Card.
Remark:
- The type of the Master Card is according to the external reader. For example, the external reader is 125KHz HID reader, then the Master Card must be 125KHz HID card. If no Master Card is added, must press the Exit Button for at least 5 seconds before release. (This will make the previous registered Master Card invalid)
- Reset to factory default, the user’s information is still retained.
PROGRAMMING
Programming will vary depending on access configuration. Follow the
instructions according to your access configuration.
Notes:
- Remote Control: Please use the Infrared Remote Control to program the VIS-MINI-CNTRL. The “IR” on the VIS-MINI-CNTRL is the infrared receiving window, please direct the Remote Control to it.
- Cards can be read on the RFID/Keypad/Fingerprint readers only.
- PINs can be input/added on either the remote control or the external Keypad Reader, except when the Keypad Reader is 10 digits virtual card number output, the PIN(s) can only be input/added through the Keypad Reader.
- User ID Number: Assign a user ID to the user in order to track it.
- The common user ID: 0~988
- Authorized User ID: 989
- Visitor User ID: 990~999
IMPORTANT:
User IDs do not have to be processed with any leading zeros. Recording of User
ID is critical.
PIN: Can be any 4-6 digits.
Enter and Exit Program mode
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
(Factory default is 123456)
2. Exit Program Mode|
Set Master Code
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Update Master Code | **0 (New Master Code) # (Repeat New Master Code) # |
(code: 6 digits)**
3. Exit Program Mode|
Add Users with Remote Control
VIS-MINI-CNTRL Connected with Card Reader:
For the readers develop together with VIS-MINI-CNTRL, such as 3000 Series
readers, skip the below step 1; For other card readers, set the VIS-MINI-
CNTRL’s Wiegand input as below step 1 according to the Wiegand output of the
readers.
VIS-MINI-CNTRL Connected with Keypad Reader:
Can be any Keypad Reader with 4Bits, 8Bits (ASCII), 10Bits output formatSet
the VIS-MINI-CNTRL as below step 1 according to the Wiegand output and PIN
output format of the Keypad Reader.The 3000 series keypad must be set to
Wiegand mode by entering the following sequence (in the keypad itself):
*Press: , master code (Default is 999999), #, 310, #, ****
PIN(s) can be input/added on either the remote control or the external Keypad
Reader, except when the Keypad Reader is 10 digits virtual card number output,
the PIN(s) can only be input/added through the Keypad Reader.
Set Wiegan Format
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Wiegand Format Auto-Identification
OR
2. Specified Wiegand Format
| 8 0 # (factory default)
8 (26~44, 56, 58) #
3. Exit Program Mode|
Add Common Users
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
Add Card User
2. Using Auto ID: (Allows
VIS-MINI-CNTRL to assign Card to next available User ID number)
OR
2. Select Specific ID
(Allows the device to define a specific User ID to associate the card to)
OR
2. Add Card: Block Enrollment (Allows Master to add up to 988 cards to the Reader in a single step.) Takes 2 minutes to program
| 1 (Read Card) / (Input 8/10 Digits Card Number) #
The cards can be added continuously.
1 (User ID) # (Read Card) / (Input 8/10 Digits Card Number) #
1 ( User ID) # (Card quantity) #
(The first card 8/10 Digits Number) #
Cards’ number must be consecutive.
Card quantity = number of cards to be enrolled
Add PIN User|
2. Using Auto ID
(Allows VIS-MINI-CNTRL to assign PIN to next available User ID number)
OR
2. Select Specific ID
(Allows the device to define a specific USer ID to associate the PIN to)
| 1 (Input PIN) #
1 (User ID) # (Input PIN) #
Tips for PIN Security (Only valid for 6 digits PIN):
For higher security we allow you to hide your correct PIN with other numbers
up to a max. of 9 digits.
Example PIN 123434
You could use (123434) or (123434) (”” can be any numbers from 0~9)
VIS-MINI-CNTRL Connected with Fingerprint Reader:
For example: Connect the fingerprint reader to VIS-MINI-CNTRL, two steps to
enroll the valid fingerprint.
- Add the Fingerprint (A) on the reader
- ) Add the same Fingerprint (A) on VIS-MINI-CNTRL as below:
Enter Program Mode: (Master Code) # |
---|
2
OR
2
| 1 (Press Fingerprint A on the reader) (Repeat Fingerprint A on the reader) # (ID auto allocated)
1 (User ID) # (Press Fingerprint A on the reader) (Repeat Fingerprint A on the reader) # (Select specific ID)
3| Exit:
Set Relay Configuration
The relay configuration sets the behavior of the output relay on activation.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Add Card
OR
2. Specified Wiegand Format
| 1 (User ID) # (Read Card / Input 8/10 Digits Card Number) #
1 (User ID) # (PIN) #
3. Exit Program Mode|
Set Access Mode
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Add Card
OR
2. Specified Wiegand Format
| 1 (User ID) # (0~9) # (Read Card / Input 8/10 Digits Card Number) #
1 (User ID) # (0~9) # (PIN) #
(0~9 means times of usage, 0=10 times)
3. Exit Program Mode|
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed entry attempts (Factory is
OFF). It can be set to deny access for 10 minutes after engaging or disengage
only after entering a valid card/PIN or Master code/card.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Delete User – By Card/PIN
OR
2. Delete User – By ID number
OR
2. Delete User – By Card number
OR
2. Delete All User
| 2 (Read Card) / (Input PIN) # 2 (User ID) #
2 (Input 8/10 digits card number) #
2 (Master Code) #
3. Exit Program Mode|
Advanced Application
Collection Card Mode
After this mode is turned on, all the cards can open the lock, at the same
time, all cards are added in the device.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Pulse Mode
OR
2. Toggle Mode
| 3 (1~99) # (Factory default) The relay time is 1~99 seconds. (Factory default is 5 seconds) 3 0 #
Sets the relay to ON/OFF Toggle mode
3. Exit Program Mode|
Programming Step| Keystroke Combination
---|---
1. Enter Program Mode| (Master Code) #
2. Card access| 4 0 #
OR|
2. Card + PIN access| 4 1 #
OR|
2. Card or PIN access| 4 3 (Factory default)
OR|
2. Multi cards/PINs access| 4 3 (2~9) #
3. Exit Program Mode|
User Information Transfer (Valid for Card/PIN Users)
The enrolled user can be transferred from a “Master” unit to a “Slave” unit. The Master code must be the same in the “Master” and the “Slave” unit.
Remarks:
- The Master Units and Accept Units must be VIS-MINI-CNTRL.
- The Master Code of the Master Unit and the Accept Unit(s) must be set to the same. Program the transfer operation on Master Unit only.
- If the Accept Unit(s) are already with the users enrolled, it will be covered after transfer. For full 986 users enrolled, the transfer takes about 30 seconds.
Programming Step | Keystroke Combination |
---|---|
1. Enter Program Mode | (Master Code) # |
2. Set transferring | 9 8 # |
Within 30 seconds, Green LED shines, after one beep, the LED will turn RED,
which means the users’ information has been transferred successfully.
3. Exit Program Mode|