dormakaba 909 Surface And Flush Mount Rocker Switches Installation Guide
- September 23, 2024
- dormakaba
Table of Contents
dormakaba 909 Surface And Flush Mount Rocker Switches
Product Specifications
- Switch Mode: Momentary Action (can be converted to maintained switch mode)
- Switch Configuration: SPDT N/O or N/C
- Switch Rating: 10A @ 250V
- Standard Finish: Beige (plastic)
Product Usage Instructions
909 Surface Mount Instructions:
- Remove the decorative bezel around the switch.
- Optional: To convert to maintained switch mode, carefully remove the spring under the rocker switch.
- Mount the switch base in the desired location.
- Connect wires under appropriate terminals (Refer to Fig. 1).
- Replace the decorative bezel.
909 Flush Mount Instructions:
- Pry off the decorative bezel around the switch and remove the toggle.
- Cut a hole of size 2-1/4 x 1-1/4 in the drywall.
- Connect wires under appropriate terminals (Refer to Fig. 2).
- Insert the switch into the hole and tighten the metal slot screws securely.
- Replace the toggle and decorative bezel.
NOTE: Specifications are subject to change without notice.
N/C – Normally Closed, N/O – Normally Open, C – Common
- Surface-mounted switches only may be converted to Maintained Switch Mode
Frequently Asked Questions
- Q: Can surface-mounted switches be converted to Maintained Switch Mode?
- A: Yes, surface-mounted switches can be converted to Maintained Switch Mode by removing the spring under the rocker switch.
- Q: What are the different contact types on the switch?
- A: The switch has N/C (Normally Closed), N/O (Normally Open), and C (Common) contacts for power out.