Patura 102.0723 Integrated Bowl Heater Instruction Manual

September 19, 2024
patura

Patura 102.0723 Integrated Bowl Heater Instruction Manual

100.1355 Mod. 135P-H33-17

with integrated bowl heating 24 V, 33 W + 17 W heating cable for horses, calves, sheep, goats water pressure from 1 – 5 bar / 14,5 – 72,5 psi

Spare Parts

Dimensions (mm)

Accessories

Fixation

Adjustment of water level

Cleaning

Water Connection

Electrical connection

Fixation
Fix the bowl with four appropriated screws onto the wall as well as on vertical tubes 1½”- 3½” (48 – 102 mm) using 1x adapter plate (101.1240).
To take off the cover: unscrew the screw (102.0723).
Observe the norm DIN 1988 / DIN EN 1717!
Hole Distance: 2x 135 mm

Installation Height
· for horses: 90 – 110 cm / 35,4 – 43,3″
· for calves: 40 – 60 cm / 15,8 – 23,7″
· for sheep: 30 – 40 cm / 11,8 – 15,8″

Attention!
Flush water line well before you connect the bowl!

Water pressure
Maximum 5 bar / 72,5 psi water pressure!

Water Connection
We recommend as horizontal tube the use of a ¾” pipe. It is foreseen for installation of the connecting pipe ½” the use of SUEVIA Boring Bracket (101.0529). Water connection is possible from the right side, laterally.

For connection from the top or bottom angular screwing ½” (102.0352) is recommended. For connection from the left side the float valve can be inversed.

Adjustment of water level
Water level in the bowl can be adjusted by changing the height of the float valve.

Procedure:
Unscrew the screws (102.0723) and take off the valve cover. Loosen the knurled nut (102.0621) and adjust the floater at the desired height.
Tighten the knurled nut (102.0621), put the valve cover back and tighten it well with the screws (102.0723).

Cleaning
Stop water flow, open the drainage plug (102.1819). Drain the water and clean the bowl. Close the drainage plug, open the water flow.

Integrated bowl heating
Frost-protected down to -15°C by a heating element (24 V, 33 W).
Heating element (102.1784) is mounted and protected in the cover (102.1782) under the bowl. The remaining 17 W (approx. 2 m cable length) is used to keep the feed-pipe frost-free. If this heating cable is installed on plastic pipes, make sure that this water pipe is suited for warm and cold water. For better heat distribution the water pipe has to be wrapped first with an aluminium adhesive tape (101.1099). An integrated thermostat switches the heating on at 6°C and off at 16°C. It is also possible to install the drinkig bowl into a water circuit. Connection set for ¾” circuits (103.3010).

Cables must be protected against bites on site.

Max. cable lengths:

Guidelines. Please note cable data sheets and local standards.

Electric connection
All installation, maintenance and inspection works must be carried out only by an authorised and qualified specialist. Local norms must be respected. We recommend to ground the drinker due to electrostatic discharges.

06/2024  Technical data can be changed without prior notice