Cell2 MICROBAR-EX Lighthead 3LED TIR Blue Owner’s Manual
- September 17, 2024
- Cell2
Table of Contents
Cell2 MICROBAR-EX Lighthead 3LED TIR Blue
Product Information
Specifications:
- Model: MICRO-BAR-EX
- Mounting Type: Permanent Mount, Single-Bolt Mount Bracket, 4-Bolt Mount Brackets, Magnetic Mount, Rubber-Magnet Mount
- Flash Patterns: 24 different patterns available
- Power Input:
- RED: To +VDC (fuse @ 9A)
- BLACK: To Chassis Ground (-)
- BLUE: Flash patterns & Synchronisation
Product Usage Instructions
Permanent Mount Usage:
To change flash patterns:
- Momentarily apply +VDC to BLUE wire for flash pattern change.
- Connect BLUE wires of all minibars together for synchronization; all units must be set at the same pattern.
Magnetic Mount Usage:
Model comes with a Dual button cigar-plug for power. To change flash patterns:
- Momentarily apply +VDC to BLUE wire for flash pattern change.
- Quickly press the flash pattern button once for the next pattern or press three times to reset to FP#1.
Mounting Instructions:
- Single-Bolt Mount Bracket:
- Mount the minibar using the suggested diameter and the provided mounting accessories.
- 4-Bolt Mount Brackets:
- Securely attach the minibar using the provided accessories and suggested diameter.
- Magnetic Mount:
- Attach the minibar using the magnet screw and anti-scratch sticker provided.
- Note: Do not use magnetically mounted warning devices on vehicles in motion.
- Rubber-Magnet Mount:
- Securely attach the minibar using the rubber magnet and mounting accessories provided.
Frequently Asked Questions (FAQ):
-
Q: How do I change the flash patterns on the minibar?
A: Momentarily apply +VDC to the BLUE wire for flash pattern change. Connect the BLUE wires of all minibars together for synchronization. -
Q: Can I look directly into the LEDs while the minibar is in operation?
A: No, it is not recommended to look directly into the LEDs while in operation as it may cause momentary blindness and/or eye damage.
PERMANENT MOUNT
WARNING: Do not look directly into LEDs while in operation; may cause momentary blindness and/or eye damage.
FLASH PATTERNS
Momentarily apply +VDC to BLUE:
- Once for next pattern
- Quickly 3 times for reset to FP#1
FP# | Flash Patterns |
---|---|
1 | Random |
2 | Rotating (slow) |
3 | Rotating (fast) |
4 | Single (split) |
5 | Double (split) |
6 | Quad (split) |
7 | Quint (split) |
8 | Mega (split) |
9 | Ultra (split) |
10 | Single-Quad (split) |
11 | Single H/L (split) |
12 | Single (all) |
13 | Double (all) |
14 | Quad (all) |
15 | Quint (all) |
16 | Mega (all) |
17 | Ultra (all) |
18 | Single-Quad (all) |
19 | Single H/L (all) |
20 | Steady Half |
21 | Single (2Hz) |
22 | Double (R65) |
23 | Triple (2Hz) |
24 | Quad (2Hz) |
Note: This unit is not factory set at FP#1
MOUNTING
SINGLE-BOLT MOUNT BRACKET
4-BOLT MOUNT BRACKETS
MAGNETIC MOUNT
Model: with Dual button cigar-plug.
WARNING:
It is not recommended to use magnetically mounted warning devices on vehicles
in motion. Usage is at the sole risk and responsibility of the user.
FLASH PATTERNS
Momentarily apply +VDC to BLUE:
- Once for next pattern
- Quickly 3 times for reset to FP#1
FP# | Flash Patterns |
---|---|
1 | Random |
2 | Rotating (slow) |
3 | Rotating (fast) |
4 | Single (split) |
5 | Double (split) |
6 | Quad (split) |
7 | Quint (split) |
8 | Mega (split) |
9 | Ultra (split) |
10 | Single-Quad (split) |
11 | Single H/L (split) |
12 | Single (all) |
13 | Double (all) |
14 | Quad (all) |
15 | Quint (all) |
16 | Mega (all) |
17 | Ultra (all) |
18 | Single-Quad (all) |
19 | Single H/L (all) |
20 | Steady Half |
21 | Single (2Hz) |
22 | Double (R65) |
23 | Triple (2Hz) |
24 | Quad (2Hz) |
Note: This unit is not factory set at FP#1
MOUNTING
MAGNET MOUNT
RUBBER-MAGNET MOUNT