EVYB35LN9VFT EVY Cold Basic Advanced Controllers
Specifications
- Controllers for refrigerated cabinets and display units
- Power supply: 115-230 Vac3 analogue inputs for configurable PTC, NTC, or Pt 1000 probes
- Door switch digital input
- Multi-purpose digital input
- Management of variable capacity PWM compressors (Embraco, Secop, and Tecumseh)
- Models with 3, 4, or 5 digital outputs (electro-mechanical relays)
- Main relay: 16 A res. @ 250 Vac or 30 A res. @ 250 Vac (according to the model)
- Sealed relays compliant with the standard EN 60079-15 Alarm buzzer
- TTL MODBUS slave port for the EVconnect app or the EPoCA remote monitoring system
- Hot or cold mode regulation
Product Usage Instructions
Electrical Connection
Ensure to follow proper electrical connection guidelines provided in the
manual.
First-Time Use
- Carry out the installation following the instructions in the section MEASUREMENTS AND INSTALLATION.
- Power up the device to initiate an internal test.
- Configure the device based on the recommended configuration parameters for first-time use.
- Disconnect the device from the mains.
- Make the electrical connection as shown in the Electrical Connection section without powering up the device.
- To perform configuration upload or download, connect the EVJKEY programming tool.
Measurements and Installation
Measurements are expressed in mm (inches). Front installation on a plastic or
metal panel with elastic holding flaps.
Note: Metal panel thickness should be between 0.8 and 1.5 mm (1/32 and 1/16
in), while plastic panel thickness should be between 0.8 and 3.4 mm (1/32 and
1/8 in).
FAQ
What are the available models and their specifications?
Models available
Purchasing Code| Number of Relays| Capacity of Main Relay| Management of
Remote Indicator
---|---|---|---
EVYB13LN9| 3| 16 A res. @ 250 VAC| No
How do I set up the device for the first time?
To set up the device for first-time use, follow the steps outlined in the
First-Time Use section of the manual.
Controllers for refrigerated cabinets and display units
- controllers for normal or low temperature units
- power supply 115… 230 Vac
- 3 analogue inputs for configurable PTC, NTC or Pt 1000 probes
- door switch digital input
- multi-purpose digital input
- management of variable capacity PWM compressors (Embraco, Secop and Tecumseh), rather than variable capacity compressors or 0-10 V modulating fans
- models with 3, 4 or 5 digital outputs (electro-mechanical relays)
- main relay 16 A res. @ 250 Vac or 30 A res. @ 250 Vac (according to the model)
- sealed relays compliant with the standard EN 60079-15
- alarm buzzer
- TTL MODBUS slave port for the EVconnect app or the EPoCA remote monitoring system
- hot or cold mode regulation
Models available
Purchasing code| Number of relays| Capacity of main relay| Manag. of remote
indicator
---|---|---|---
EVYB13LN9| 3| 16 A res. @ 250 VAC| no
EVYB33LN9| 3| 30 A res. @ 250 VAC| no
EVYB14LN9| 4| 16 A res. @ 250 VAC| no
EVYB34LN9| 4| 30 A res. @ 250 VAC| no
EVYB15LN9| 5| 16 A res. @ 250 VAC| no
EVYB35LN9| 5| 30 A res. @ 250 VAC| no
EVYB35LN9VFT| 5| 30 A res. @ 250 VAC| yes
MEASUREMENTS AND INSTALLATION
Measurements are expressed in mm (inches). Front installation on a plastic or metal panel (with elastic holding flaps).
N.B.
The metal panel must be between 0.8 and 1.5 mm (1/32 and 1/16 in) thick, while
the plastic panel must be between 0.8 and 3.4 mm (1/32 and 1/8 in)
INSTALLATION PRECAUTIONS
- ensure that the working conditions are within the limits stated in the TECHNICAL SPECIFICATIONS section
- do not install the device close to heat sources, equipment with a strong magnetic field, in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations or shocks
- in compliance with safety regulations, the device must be installed properly to ensure adequate protection from contact with electrical parts. All protective parts must be fixed in such a way as to need the aid of a tool to remove them.
ELECTRICAL CONNECTION
N.B.
- use cables of an adequate section for the current running through them
- to reduce any electromagnetic interference, locate the power cables as far away as possible from the signal cables
- the K3 and K4 relays are not available in models with 3 relays
- the K4 relay is not available in models with 4 relays
- port for remote indicator is only available in model EVYB35LN9VFT
PRECAUTIONS FOR ELECTRICAL CONNECTION
- if using an electrical or pneumatic screwdriver, adjust the tightening torque
- if the device is moved from a cold to a warm place, humidity may cause condensation to form inside. Wait for about an hour before switching on the power
- make sure that the supply voltage, electrical frequency and power are within the set limits. See the section TECHNICAL SPECIFICATIONS
- disconnect the power supply before carrying out any type of maintenance
- do not use the device as a safety device
- for repairs and further information, contact the EVCO sales network
FIRST-TIME USE
-
Carry out the installation following the instructions given in the section MEASUREMENTS AND INSTALLATION.
-
Power up the device: an internal test will start up.
The test normally takes a few seconds; when it is finished, the display will switch off. -
Configure the device as shown in the section Setting configuration parameters.
Recommended configuration parameters for first-time use:
Next check that the remaining settings are appropriate; see the section CONFIGURATION PARAMETERS.
-
Disconnect the device from the mains.
-
Make the electrical connection as shown in the section ELECTRICAL CONNECTION, without powering up the device.
-
To perform the configuration upload or download, connect the EVJKEY programming key.
- To activate real-time functions, connect the EVlinking RS-485 EVIF23TSX converter.
- To control the device using the EVconnect app, connect the EVlinking BLE EVIF25TBX module then synchronise it with the app.
- To control the device using the EPoCA monitoring system or a third-party MODBUS TCP system:
- connect the EVlinking Wi-Fi EVIF25TWX module to the device and then to a local Wi-Fi network
- connect the EVlinking RS-485 EVIF24TSX converter to the device then to an IoT
- EV3 Web gateway or EVD Web. Next connect this to a free Ethernet port of a router or an Ethernet hub connected to a local network.
-
Power up the device again.
USER INTERFACE AND MAIN FUNCTIONS
Switching the device on/off
- If POF = 1 (default), touch the ON/STAND-BY key for 4
If the device is switched on, the display will show the P5 value (default “cabinet or product temperature”); if the display shows an alarm code, see the section ALARMS.
If Loc = 1 (default) and 30 s have elapsed without the keys being pressed, the display will show the “Loc” label and the keypad will lock automatically.
Unlocking the keypad
Touch a key for 1 s: the display will show the label “UnL”.
Setting the setpoint (if r3 = 0, default)
Check that the keypad is not locked.
Setting the 0-10 V evaporator fan speed for normal operation (percentage 0-10
V output; available if Ao1 = 3 and F30 = 0)
Check that the keypad is not locked.
Activating manual defrost (if r5 = 0, default)
Check that the keypad is not locked and that overcooling is not active
- Touch the DEFROST key for 2 s
If P3 = 1 (default), defrost is activated provided that the evaporator temperature is lower than the d2 or d2b threshold.
Manually activating/deactivating the overcooling, overheating and
energysaving functions
Check that the keypad is not locked.
- Touch the DOWN key.
If u1c… u5c = 16, the evaporator fans will operate at this speed during the
energy-saving function.
If u1c… u5c = 18, the condenser fans will operate at this speed during the
energy-saving function.
Manually switching the cabinet light on/off (if u1c… u5c = 5)
- Touch the CABINET LIGHT key
Switching the demisting function on (if u1c… u5c = 6)
- Touch the CABINET LIGHT key (for 2 s if u1c… u5c = 5)
The demisting function stays on for the duration of u6.
Switching auxiliary load 1 on/off (if u1c… u5c = 10)
- Touch the CABINET LIGHT key (for 2 s if u1c… u4c = 5)
If u1c… u5c = 6, it also switches the demisting function on.
Switching auxiliary load 2 on/off (if u1c… u5c = 11)
- Touch the ON/STAND-BY key
Silencing the buzzer (if u9 = 1, default) Touch a key.
If u1c… u5c = 11 and u4 = 1, the alarm output is deactivated.
ADDITIONAL FUNCTIONS
Setting the date, time and day of the week (available when the EVlinking
RS485 EVIF23TSX converter, the EVlinking BLE EVIF25TBX module or the EVlinking
Wi-Fi EVIF25TWX module is connected)
Check that the keypad is not locked.
Activating the high or low humidity function (if F0 = 5)
Check that the keypad is not locked.
If u1c… u5c = 16, the evaporator fans will operate at this speed during low humidity function.
Viewing/deleting HACCP alarm information
Check that the keypad is not locked.
Example of alarm information (e.g. a high temperature alarm).
Viewing the minimum and maximum temperatures saved in the last 72 hours
Check that the keypad is not locked.
The device saves the rEt value (default “temperature of the cabinet or the
product, not during defrost, pre-drip or dripping and with the fans off”).
When the device is switched on/off, these temperatures are deleted.
Viewing/deleting compressor operation days
Check that the keypad is not locked.
Viewing the temperature detected by the probes
Check that the keypad is not locked
Displaying the percentage of power generated by the analogue output
SETTINGS
Setting configuration parameters
Restoring factory settings
N.B.
Check that the factory settings are appropriate; see the section CONFIGURATION
PARAMETERS
CONFIGURATION PARAMETERS
EVCO S.p.A. | EVY Cold BASIC | Instruction sheet ver. 1.0 | Code 104YCBE103 | Page 4 of 5 | PT 50/23
Maximum permitted length for connection cables:
power supply: 10 m (32.8 ft)| analogue inputs: 10 m (32.8 ft)
digital inputs: 10 m (32.8 ft)| analogue outputs: 3 m (9.84 ft)
digital outputs: 10 m (32.8 ft)| port for remote indicator: 3 m (9.84 ft)
Operating temperature:| from -5 to 60 °C (from 23 to 140 °F)
Storage temperature:| from -25 to 70 °C (from -13 to 158 °F)
Operating humidity:| relative humidity without condensate from 10 to 90 %
Pollution status of the control device:| 2
Compliance:
RoHS 2011/65/EC| WEEE 2012/19/EU
REACH (EC) Regulation no. 1907/2006| LVD 2014/35/EU
Power supply:| 115…230 Vac (+10 % -15%), 50/60 Hz (±3
Hz), max. 11 VA, 6.4 W
Earthing methods for the control device:| none
Rated impulse withstand voltage:| 2.5 kV
Overvoltage category:| II
Software class and structure:| A
Analogue inputs:| 3 for configurable PTC, NTC or Pt 1000
probes
PTC probes:| Type of sensor:| KTY 81-121 (990 W @ 25 °C, 77 °F)
Measurement field:| from -50 to 150 °C (from -58 to 302 °F)
Resolution:| 0.1 °C (1 °F)
NTC probes:| Type of sensor:| ß3435 (10 kW @ 25 °C,77 °F)
Measurement field:| from -40 to 105 °C (from -40 to 221 °F)
Resolution:| 0.1 °C (1 °F)
Probes Pt 1000:| Type of sensor:| 1 kW @ 0 °C, 32 °F
Measurement field:| from -99 to 199 °C (from -146 to 390 °F)
Resolution:| 0.1 °C (1 °F)
Digital inputs:| 2 voltage-free (door switch and multi- purpose)
Voltage-free:| Type of contact:| 3.3 Vdc, 1 mA
Power supply:| none
Protection:| none
Analogue outputs:| 1 configurable PWM or 0-10 V output
PWM output:| Output:| 11 Vdc (±15%), 10 mA max
Frequency:| 0… 150 Hz
Protection:| none
0-10 V
output:
| Minimum applicable imped-
ance:
| 1 kW
Resolution:| 0.01 V
Digital outputs:| up to 5 with sealed electro-mechanical relays in compliance
with the EN 60079-15 standard
K1 relay:| SPST, 16 A res. @ 250 Vac (30 A res. @ 250
Vac in models EVYB33LN9, EVYB34LN9 and EVYB35LN9)
K2 relay:| SPDT, 8 A res. @ 250 Vac
K3 relay:| SPST, 8 A res. @ 250 Vac (not available in models with 3 relays)
K4 relay:| SPST, 8 A res. @ 250 Vac (not available in models with 3 and 4
relays)
K5 relay:| SPDT, 8 A res. @ 250 Vac
N.B.
The device must be disposed of according to local regulations governing the
collection of electrical and electronic equipment.
This document and the solutions contained therein are the intellectual
property of EVCO and thus protected by the Italian Intellectual Property
Rights Code (CPI). EVCO forbids the reproduction and distribution, even in
part, of the contents, unless express authorisation is obtained directly from
EVCO. The customer (manufacturer, installer or end user) assumes all
responsibility for the configuration of the device.
EVCO accepts no liability for any possible errors in this document and
reserves the right to make any changes at any time without prejudice to the
essential functional and safety features of the equipment.
EVCO S.p.A.
Via Feltre 81, 32036 Sedico (BL) ITALY
tel. +39 0437 8422 | fax +39 0437 83648
email info@evco.it | web
www.evco.it