hitron HT-EM4 MoCA 2.5 Network Adapter User Manual

June 6, 2024
Hitron

hitron HT-EM4 MoCA 2.5 Network Adapter

 **User Manual**

hitron HT-EM4 MoCA 2.5 Network Adapter User Manual

Getting Started

Introduction

Congratulations on purchasing the Hitron HT-EM4 MoCA 2.5 Coax to Ethernet Adapter. This easy-to-use Coax to Ethernet adapter uses your home’s existing coax wires to create a wired backbone with speeds up to 1 Gbps. Once you have a MoCA network in place you can enjoy better WiFi, better streaming and better gaming! It uses the latest MoCA 2.5 standard to create a wired MoCA backbone with speeds up to 2.5 Gbps over your home’s existing coax wires.

This User Manual explains the procedures needed to connect the Adapter.

hitron HT-EM4 MoCA 2.5 Network Adapter - overview

Package Contents

Contents will vary depending on the product purchased from retail. This adapter is sold individually and as a 2-pack Kit

Requirements
  • Available coaxial port in installation areas
  • Available electrical outlet in installation areas
Key Features
  • MoCA 2.5 for speeds up to 2.5 Gbps
  • Two coax F-type connectors and one Ethernet RJ-45 10/100/1000 Mbps connector
  • Compact to discretely fit in any home theater (110mm W x 70mm H x 25mm D)
  • Upgradable software over web-based GUI
  • Intuitive LEDs clearly display device and network status
  • Hardware DES and AES Encryption to keep your data safe from unauthorized access

Connecting the Adapters

Connecting the First Adapter

Note: Not all routers have MoCA built into the router. If your router does not support MoCA, or you are unsure if your router has MoCA, please complete Step

(A) Get a MoCA 2.5 Network Adapter and Ethernet Cable.

(B) Connect the Ethernet Cable from the Modem/Router to the MoCA 2.5 Network Adapter.

(C) Get the Coax Cable and connect the Coax Cable from the Coax Outlet on the wall to the Top Coax Port on the MoCA 2.5
Network Adapter.

Note: If you have a TV or cable set top box near your modem/router, connect a coax cable from the 2nd Coax port marked TV to the TV or set top box.

(D) Get the Power Adapter (External, 12V DC, 1A, made by AOEM, Model

ADSO12T-W120100) and connect it from the MoCA 2.5

Network Adapter to a Power Outlet.

(E) Wait until the Power Light on the front of the adapter is GREEN.

hitron HT-EM4 MoCA 2.5 Network Adapter - Wait until the Power Light on the
front of the adapter is GREEN

Connecting the Adapters

Connecting Additional Adapters

(A) Get a MoCA 2.5 Network Adapter and Ethernet Cable.

(B) Connect the Ethernet Cable from the Access Point or Device (gaming console, streaming TV player, laptop etc.) to the MoCA 2.5 Network Adapter.

(C) Get the Coax Cable and connect the Coax Cable from the Coax Outlet on the wall to the Top Coax Port on the MoCA 2.5 Network Adapter.

(D) Get the Power Adapter and connect it from the MoCA 2.5 Net work Adapter to a Power Outlet.

(E) Wait until the Power Light on the front of the adapter is GREEN and the MoCA light turns GREEN or BLUE.

Note: The MoCA light will turn Green when the MoCA network is in low speed.

hitron HT-EM4 MoCA 2.5 Network Adapter - Wait until the Power Light on the
front of the adapter is GREEN and the MoCA light turns GREEN or
BLUE.

Connecting the First Adapter

LEDs Explained

hitron HT-EM4 MoCA 2.5 Network Adapter - LEDs
Explained

Troubleshooting

Please visit the following URL for the latest FAQs
https://hitron-americas.com/HTEM4

Logging in the GUI

How to login to the GUI

Using Windows-based PC or MAC

  1. Connect the HT-EM4 Adapter to a Windows PC or MAC Using an Ethernet cable, plug one end of the Ethernet cable into the
    adapter and the other end into a Windows PC or MAC. Power on the adapter by plugging in the power supply provided.

  2. Make sure PC/MAC is on the same network as HT-EM4 Before you log into the HT-EM4’s GUI, your computer’s IP address must
    be in the same subnet as the HT-EM4. This allows your computer to communicate with the HT-EM4.

NOTE : You can find the HT-EM4’s assigned IP address by logging into your network’s gateway device and looking at the list of connected DHCP client devices. The HT-EM4 hostname will display as REV_A1000000.

  1. Log into the HT-EM4 Adapter
    Now open a web browser and type in the IP address of the HT-EM4 device in the URL bar. A pop-up will appear prompting you to sign in. Enter admin for the Username and admin for the Password. Click Sign in.

hitron HT-EM4 MoCA 2.5 Network Adapter - Using Windows-based PC or
MAC

Logging in the GUI

Status

Use this screen to see general information about your HT-EM4’s hardware, its software, and its connection to the Internet.

Click Status. The following screen displays.

hitron HT-EM4 MoCA 2.5 Network Adapter - Status

Logging in the GUI

  • Model Name This displays your device’s model designation (HT-EM4)

  • Hardware Version This displays the version number of the HT-EM4’s physical hardware.

  • Software Version This displays the version number of the software that controls the HT-EM4.

  • SOC Version This displays the version number of the HT-EM4’s chipset.

  • Device MoCA Version This displays the version number of the HT-EM4’s MoCA standard.

  • Network MoCA Version This displays the version number of the current MoCA network.

  • IP Address This displays the HT-EM4’s IP address. This IP address is automatically assigned to the HT-EM4.

  • MAC Address This displays the Media Access Control (MAC) address of the HT-EM4’s radio frequency (RF) module.

  • Link Status This displays whether or not the HT-EM4 is connected over the cable network.
    • Up displays when the HT-EM4 is connected.
    • Down displays when the HT-EM4 is not connected.

  • Beacon Channel This displays the channel frequency used to transmit beacons.

  • Primary Channel This displays the primary channel frequency of the HT-EM4.

  • Secondary Channel This displays the secondary channel frequency of the HT-EM4.

  • First Channel This displays the first channel frequency of the HT-EM4.

  • Number of Channels This displays the number of the HT-EM4’s working channel.

  • Ethernet TX This displays the number of Ethernet packets transmitted by this node since MoCA link up.

  • Ethernet RX This displays the number of Ethernet packets received by this node since MoCA link up.

  • Refresh Use this button to have the Status screen reload with new data

Logging in the GUI

Network

Use this screen to modify the HT-EM4 IP mode.
Click Network. The following screen displays.

hitron HT-EM4 MoCA 2.5 Network Adapter - Network

IP Configuration This field allows you to select the IP Mode that you want the HT-EM4 to use.

  • DHCP automatic configuration Your HT-EM4 will receive a dynamic IP address from your Router.
  • Link Local automatic configuration Choose it if there’s no DHCP server in your network, and you want to make zero-config for the IP.
  • DHCP & Link Local automatic configuration Your HT-EM4 will receive a dynamic IP address from your Router.
  • Static IP Address Allow you to configure your HT-EM4’s IP address, netmask, and gateway manually

Logging in the GUI

MoCA

Use this screen to view and modify the HT-EM4’s MoCA-related settings.

NOTE : Do not change any of the settings in this screen unless you have a good reason to do so!
Click MoCA. The following screen displays.

hitron HT-EM4 MoCA 2.5 Network Adapter - MoCA

Logging in the GUI

  • Adapter Name Select the adapter name that you wish to use from the dropdown list.

  • Network Search Enabled Use this field to control whether the HT-EM4 should look for a MoCA network to which to connect.
    • Check the box to have the HT-EM4 search for a MoCA network and, if it finds one, connect to it. If the MoCA network to which the HT-EM4 is currently connected goes offline, the HT-EM4 will look for another MoCA network.
    • Uncheck the box if you do not want the HT-EM4 to search for a MoCA network. If the HT-EM4 is currently connected to a MoCA network, it will remain connected. If the MoCA network to which the HT-EM4 is currently connected goes offline, the HT-EM4 will not look for another.

  • Channel Plan The MoCA specification defines several channel plans for communication on the cable network (see MoCA Overview on page 26).
    This field allows you to select the channel plan that you want the HT-EM4 to use. Select the channel plan that you wish to use from the dropdown list.

hitron HT-EM4 MoCA 2.5 Network Adapter - Channel Plan

  • LOF This field allows you to set the Last Operating Frequency that you want the HT-EM4 to use.
  • Tx Power Use this field to set the power at which the HT-EM4 transmits (TX) over the cable network, from 0 to 10.
  • Beacon Power Level Use this field to set the HT-EM4’s beacon power on the cable network, from 0 to 10. The MoCA beacon allows other devices on the cable network to detect the HTEM4.

Logging in the GUI

  • Preferred NC(Network Controller) Each MoCA network has a Network Coordinator (NC) which acts as a manager for all the other devices on the cable network.
    • By default, the NC is chosen from the pool of MoCA devices based on its suitability (signal strength, etc.) To base NC status on merit, or if you have specified another device as “preferred” and do not want the HT-EM4 to compete with it, uncheck the box.
    • When one device is set to be the “preferred” NC, it will be the NC whenever it is available on the network (if multiple devices are “preferred”, the most suitable one will be chosen). Check the box to add the HT-EM4 to the preferred group.

  • Security Enabled The MoCA specification allows you to secure your network by defining a password that all devices must use before they join the network. Use this to turn encryption on the cable network on or off.
    • Check the box (recommended) to turn cable network encryption on. When encryption is on, only devices that supply the common Password can communicate over the cable network.
    • Uncheck the box to turn cable network encryption off. When encryption is off, any device connected to the cable wiring can
    communicate over the cable network. The Password you set has no effect.

  • New Password When Security is enabled, enter the cable network password you want to use. All MoCA devices must be configured to use this passwordbefore they may connect to the cable network.

  • Confirm Password Enter the cable network password again that you want to use.

  • Save Click this to save your changes to the fields in this screen.

  • Cancel Click this to return the fields in this screen to their last-saved values without saving your changes.

Logging in the GUI

Admin

Use this screen to perform the firmware upgrade, and reboot or reset the HT- EM4.

Click Admin. The following screen displays.

hitron HT-EM4 MoCA 2.5 Network Adapter - Admin

Upgrade
  • Choose File Click Choose File to select the new firmware.
  • Upgrade Click Upgrade to perform a firmware upgrade.
  • Clear Selection Click Clear Selection to return the fields in this screen to their last-saved values without saving your changes.
Device Reset
  • Reboot Click Reboot to restart your HT-EM4, restoring its settings to their last-saved values.
  • Restores Defaults Click Restores Defaults to return your HT-EM4 to its factory default settings. When you do this, all your user-configured settings are lost, and cannot be retrieved.

Notices

Warranty

Please go to hitron-americas.com/legal/limited-warranty-statement/ for a copy of the warranty statement.

Important Safety Instructions

Basic safety precautions should always be followed to reduce the risk of fire, electrical shock, and personal injury, including the following:

  • Do not use this product near water – for example, near a bathtub, kitchen sink, laundry tub, or swimming pool, or in a wet basement; only clean with dry cloth.

  • Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus including amplifiers that produce heat.

  • Do not use the telephone to report a gas leak in the vicinity of the leak.

  • Use only the power cord and batteries indicated in this manual if applicable.
    Note : you may need to reword for batteries or adapters.

  • Do not dispose of batteries in fire, as they may explode – check with local codes for possible special disposal instructions if applicable.

Coaxial Cable

If applicable, the coaxial cable screen shield needs to be connected to the Earth at the building entrance per ANSI/NFPA 70, the National
Electrical Code (NEC), in particular Section 820.93, “Grounding of Outer Conductive Shield of a Coaxial Cable,” or in accordance with
local regulation.

FCC Class B Equipment

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment

Notices

does cause harmful interference to radio or television reception, which can be determined by turning the equipment of and on, the user is encouraged to try and correct the interference by implementing one or more of the following measures:

  • Reorient or relocate the device;
  • Increase the separation between the equipment and receiver;
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected (applicable only to powerline products);
  • Consult the dealer or an experience radio or television technician for help.

Declaration of Conformity for Products Marked with the FCC logo–USA Only

This device complies with Part 15 of the FCC Rules license-exempt RSS standard(s). Operation is subject to the following two conditions:

  1. This device may not cause harmful interference;
  2. This device must accept any interference received, including interference that may cause undesired operation of the device.
Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Actiontec Electronics, Inc, may void the user’s authority to operate the equipment.

Declaration of Conformity for Products Marked with the Industry Canada (IC)–Canada only

This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:

3. This device may not cause harmful interference;
4. This device must accept any interference received, including interference that may cause undesired operation of the device.

Notes

hitron HT-EM4 MoCA 2.5 Network Adapter - Notes

Tech Support

To access user manuals, Frequently Asked Questions etc, visit our website at: www.hitron-americas.com/HTEM4

Warning

– Risk of electrical shock. Do not expose the device to water or moisture.
– The device is a high-performance communications device de signed for home and office environments.
– Do not use the device outdoors. Keep the device in an environment between 0°C – 45°C (32°F – 113°F). To avoid overheating, do NOT
place any object on top of the device.
– Do not restrict the flow of air around the device.
– The manufacturer assumes no liabilities for damage caused by any improper use of the device.

Disclaimer

The manufacturer assumes no liabilities with respect to the contents of this document. The manufacturer also reserves the right to revise this document or update the content thereof without any obligation to notify any person of such revisions or amendments. Hitron and the Hitron logo are registered trademarks of Hitron Technologies in the US or other countries. Product photo may differ from the actual product. Specifications subject to change without notice.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hitron User Manuals

Related Manuals